Literature DB >> 7783014

Prospective clinical evaluation of mandibular implant overdentures: Part I--Retention, stability, and tissue response.

D R Burns1, J W Unger, R K Elswick, D A Beck.   

Abstract

Seventeen subjects with preexisting conventional complete dentures were evaluated in this prospective clinical study. Two implants were placed bilaterally in the anterior mandible. In a crossover experimental design, the conventional dentures were modified, and the retention, stability, and tissue response for conventional dentures were compared with implant overdentures that had O-ring and magnet overdenture attachments for all subjects. The study indicated statistical superiority of the implant overdenture to the conventional denture. The O-ring attachment proved significantly better than the magnet attachment for retention and stability. The soft tissue response showed a slight but significant improvement with implant overdenture therapy.

Mesh:

Substances:

Year:  1995        PMID: 7783014     DOI: 10.1016/s0022-3913(05)80331-2

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  19 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Clinical retention force development of double crowns.

Authors:  Stefan Bayer; Helmut Stark; Lina Gölz; Ludger Keilig; Dominik Kraus; Anja Hansen; Norbert Enkling
Journal:  Clin Oral Investig       Date:  2011-03-01       Impact factor: 3.573

3.  A finite element analysis of stress distribution in the bone, around the implant supporting a mandibular overdenture with ball/o ring and magnetic attachment.

Authors:  Jins John; V Rangarajan; Ravindra C Savadi; K S Satheesh Kumar; Preeti Satheesh Kumar
Journal:  J Indian Prosthodont Soc       Date:  2012-03-09

4.  The influences of implant angulations in one and two directions on the retentive properties of overdenture attachments: an in vitro study.

Authors:  Parsa Atashrazm; Mohammad Hossein Dashti; Leila Zamani Alavijeh; Samira Azarmaeh; Sayena Mahdizadeh
Journal:  J Indian Prosthodont Soc       Date:  2013-04-12

5.  Comparison of three attachments in implant-tissue supported overdentures: an in vitro study.

Authors:  F Tabatabaian; F Alaie; K Seyedan
Journal:  J Dent (Tehran)       Date:  2010-09-30

Review 6.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

7.  A clinical investigation of the relationship between the quality of conventional complete dentures and the patients' quality of life.

Authors:  Sara A Alfadda; Hayam A Al-Fallaj; Hajar A Al-Banyan; Ruba M Al-Kadhi
Journal:  Saudi Dent J       Date:  2015-01-29

Review 8.  Biomechanical factors related to occlusal load transfer in removable complete dentures.

Authors:  Jarosław Żmudzki; Grzegorz Chladek; Jacek Kasperski
Journal:  Biomech Model Mechanobiol       Date:  2014-12-20

9.  Comparison of different final impression techniques for management of resorbed mandibular ridge: a case report.

Authors:  Bhupender Yadav; Manisha Jayna; Harish Yadav; Shrey Suri; Shefali Phogat; Reshu Madan
Journal:  Case Rep Dent       Date:  2014-08-10

10.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.