Literature DB >> 15369470

Retention force and fatigue strength of overdenture attachment systems.

D M Botega1, M F Mesquita, G E P Henriques, L G Vaz.   

Abstract

This study evaluated retention force and fatigue resistance of two overdenture attachment systems. Twenty samples (O-ring and Bar-Clip) from two manufacturers (Conexão Sistemas de Prótese and Lifecore Biomedical) were prepared and divided into four groups: (i) Conexão/O-ring; (ii) Conexão/Bar-Clip; (iii) Lifecore/O-ring and (iv) Lifecore/Bar-Clip, with five samples in each group. They were submitted to mechanical fatigue test using a servohydraulic machine performing 5500 cycles of insertion and removal (f=0.8 Hz), immersed in artificial saliva. Retention force values were obtained three times (0, 3000 and after 5500 cycles) simulating the clinical service, using a tensile strength at 1 mm min(-1) and load cell of 1 kN. Data were analysed with analysis of variance and Tukey's test at 5% level. Results showed that Conexão/Bar-Clip specimens had significantly higher retention values than Lifecore/Bar-Clip (44.61 and 18.44 N, respectively), Conexão/O-ring specimens had significantly lower values than Lifecore/O-ring (13.91 and 19.75 N, respectively). Conexão/Bar-Clip values were always significantly higher than those of Conexão/O-ring group (44.61 and 13.91 N, respectively). Lifecore (O-ring and Bar-Clip) presented similar values (19.75 and 18.44 N, respectively). The systems evaluated showed satisfactory retention force values, before and after fatigue testing. Conexão/Bar-Clip specimens presented the highest values. A 5-year simulation of insertion and removal did not decrease retention values or fracture components.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15369470     DOI: 10.1111/j.1365-2842.2004.01308.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  20 in total

1.  An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.

Authors:  Abdalbseet A Fatalla; Ke Song; Tianfeng Du; Yingguang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2012-01-27

2.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

3.  Clinical retention force development of double crowns.

Authors:  Stefan Bayer; Helmut Stark; Lina Gölz; Ludger Keilig; Dominik Kraus; Anja Hansen; Norbert Enkling
Journal:  Clin Oral Investig       Date:  2011-03-01       Impact factor: 3.573

4.  CAD/CAM milled removable complete dentures: an in vitro evaluation of trueness.

Authors:  Murali Srinivasan; Yoann Cantin; Albert Mehl; Harald Gjengedal; Frauke Müller; Martin Schimmel
Journal:  Clin Oral Investig       Date:  2016-11-08       Impact factor: 3.573

5.  New mini dental implant attachments versus O-ring attachment after cyclic aging: Analysis of retention strength and gap space.

Authors:  Abdalbseet A Fatalla; Ke Song; Ying-Guang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

6.  Retention force measurement of telescopic crowns.

Authors:  Stefan Bayer; Helmut Stark; Sebastian Mues; Ludger Keilig; Anja Schrader; Norbert Enkling
Journal:  Clin Oral Investig       Date:  2009-07-17       Impact factor: 3.573

7.  Hader bar and clip attachment retained mandibular complete denture.

Authors:  Kunwarjeet Singh; Nidhi Gupta; Vikram Kapoor; Ridhimaa Gupta
Journal:  BMJ Case Rep       Date:  2013-10-21

8.  Wear of double crown systems: electroplated vs. casted female part.

Authors:  Stefan Bayer; Dominik Kraus; Ludger Keilig; Lina Gölz; Helmut Stark; Norbert Enkling
Journal:  J Appl Oral Sci       Date:  2012 May-Jun       Impact factor: 2.698

Review 9.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

10.  The effect of inter-implant distance on retention and resistance to dislodging forces for mandibular implant-tissue-supported overdentures.

Authors:  Farhad Tabatabaian; Abolfazl Saboury; Zahra Sadat Sobhani; Vicki C Petropoulos
Journal:  J Dent (Tehran)       Date:  2014-09-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.