Literature DB >> 34331593

Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Ozlem Kayikci1, Sabit Melih Ates2.   

Abstract

OBJECTIVE: This study compared the marginal and internal fit of implant-supported fixed dentures fabricated using CAD/CAM systems.
MATERIALS AND METHODS: A lower jaw model representing partial edentulism was produced. Two dental implants were inserted in the area of teeth 35 and 37, onto which cemented abutments were screwed. The model was scanned using a laboratory scanner and transferred to a design software program for substructure fabrication. Sixty substructures were fabricated out of each group for six substructure types (n = 10), cast Co-Cr (control), milling Co-Cr, laser sintering Co-Cr, titanium (Ti), zirconium, and polyetheretherketone (PEEK) substructures. The marginal and internal fit was evaluated using a silicone replica viewed under a stereomicroscope. The data were analyzed using the statistical package program for social sciences (SPSS, Chicago, IL, USA, v. 17) at a significance level of 0.05. Marginal and internal gaps were compared using the one-way ANOVA test and Tukey's post hoc test. The differences between abutment teeth were determined using the independent sample t-test.
RESULTS: There was a significant difference in the marginal gap between PEEK and Ti groups (p < 0.05) but no difference between other groups (p > 0.05). There was a significant difference in the internal gap between PEEK, laser sintering Co-Cr, and milling Co-Cr groups (p < 0.05) but no difference between other groups (p > 0.05). The PEEK group had a higher marginal gap than the Ti group and a higher internal gap than the DMLS Co-Cr group (p < 0.05).
CONCLUSION: All substructures have a marginal and internal fit within acceptable clinical limits. CLINICAL RELEVANCE: This in vitro study suggests that materials and techniques used in CAD/CAM systems improve the fitting accuracy of implant-supported fixed restorations.
© 2021. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.

Entities:  

Keywords:  CAD/CAM; Dental implant; Fixed partial dentures; Internal fit; Marginal gap

Mesh:

Substances:

Year:  2021        PMID: 34331593     DOI: 10.1007/s00784-021-04102-4

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  48 in total

1.  Marginal and internal fit of metal-ceramic crowns fabricated with a new laser melting technology.

Authors:  Katrin Quante; Klaus Ludwig; Matthias Kern
Journal:  Dent Mater       Date:  2008-04-01       Impact factor: 5.304

Review 2.  CAD/CAM imaging in dentistry.

Authors:  F Duret; J D Preston
Journal:  Curr Opin Dent       Date:  1991-04

Review 3.  CAD/CAM Ceramic Restorative Materials for Natural Teeth.

Authors:  F A Spitznagel; J Boldt; P C Gierthmuehlen
Journal:  J Dent Res       Date:  2018-06-15       Impact factor: 6.116

4.  The application of rapid prototyping in prosthodontics.

Authors:  Jian Sun; Fu-Qiang Zhang
Journal:  J Prosthodont       Date:  2012-07-23       Impact factor: 2.752

Review 5.  Ceramic dental biomaterials and CAD/CAM technology: state of the art.

Authors:  Raymond Wai Kim Li; Tak Wah Chow; Jukka Pekka Matinlinna
Journal:  J Prosthodont Res       Date:  2014-09-22       Impact factor: 4.642

6.  Three-dimensional analysis of marginal and internal fit of copings fabricated with polyetherketoneketone (PEKK) and zirconia.

Authors:  So-Yeon Bae; Jin-Young Park; Il-Do Jeong; Hae-Young Kim; Ji-Hwan Kim; Woong-Chul Kim
Journal:  J Prosthodont Res       Date:  2016-07-31       Impact factor: 4.642

7.  Marginal and internal fit of pre-sintered Co-Cr and zirconia 3-unit fixed dental prostheses as measured using microcomputed tomography.

Authors:  Elie E Daou; Hani Ounsi; Mutlu Özcan; Nadin Al-Haj Husain; Ziad Salameh
Journal:  J Prosthet Dent       Date:  2018-04-30       Impact factor: 3.426

8.  Clinical marginal and internal adaptation of CAD/CAM milling, laser sintering, and cast metal ceramic crowns.

Authors:  Ece Tamac; Suna Toksavul; Muhittin Toman
Journal:  J Prosthet Dent       Date:  2014-05-10       Impact factor: 3.426

9.  Evaluation of the fit of metal ceramic restorations fabricated with a pre-sintered soft alloy.

Authors:  Jong-Kyoung Park; Hae-Young Kim; Woong-Chul Kim; Ji-Hwan Kim
Journal:  J Prosthet Dent       Date:  2016-07-14       Impact factor: 3.426

10.  In vitro marginal and internal adaptation of metal-ceramic crowns with cobalt-chrome and titanium framework fabricated with CAD/CAM and casting technique.

Authors:  K Gurel; S Toksavul; M Toman; E Tamac
Journal:  Niger J Clin Pract       Date:  2019-06       Impact factor: 0.968

View more
  1 in total

1.  The Impact of Sintering Technology and Milling Technology on Fitting Titanium Crowns to Abutment Teeth-In Vitro Studies.

Authors:  Wojciech Ryniewicz; Łukasz Bojko; Anna M Ryniewicz
Journal:  Materials (Basel)       Date:  2022-08-24       Impact factor: 3.748

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.