Literature DB >> 29906206

CAD/CAM Ceramic Restorative Materials for Natural Teeth.

F A Spitznagel1, J Boldt1, P C Gierthmuehlen1.   

Abstract

Advances in computer-aided design (CAD) / computer-aided manufacturing (CAM) technologies and their ease of application enabled the development of novel treatment concepts for modern prosthodontics. This recent paradigm shift in fixed prosthodontics from traditional to minimally invasive treatment approaches is evidenced by the clinical long-term success of bonded CAD/CAM glass-ceramic restorations. Today, defect-oriented restorations, such as inlays, onlays, and posterior crowns, are predominately fabricated from glass-ceramics in monolithic application. The variety of CAD/CAM ceramic restorative systems is constantly evolving to meet the increased demands for highly aesthetic, biocompatible, and long-lasting restorations. Recently introduced polymer-infiltrated ceramic network CAD/CAM blocks add innovative treatment options in CAD/CAM chairside 1-visit restorations. The material-specific high-edge stability enables the CAD/CAM machinability of thin restoration margins. Full-contour zirconia restorations are constantly gaining market share at the expense of bilayered systems. Advancements in material science and bonding protocols foster the development of novel material combinations or fabrication techniques of proven high-strength zirconia ceramics. CAD/CAM applications offer a standardized manufacturing process resulting in a reliable, predictable, and economic workflow for individual and complex teeth-supported restorations. More evidence from long-term clinical studies is needed to verify the clinical performance of monolithic polymer-infiltrated ceramic network and zirconia teeth-supported minimally invasive and extensive restorations.

Entities:  

Keywords:  aesthetics dental; ceramics; clinical outcomes; computer-aided design; minimally invasive dentistry; prosthetic dentistry/prosthodontics

Mesh:

Substances:

Year:  2018        PMID: 29906206     DOI: 10.1177/0022034518779759

Source DB:  PubMed          Journal:  J Dent Res        ISSN: 0022-0345            Impact factor:   6.116


  22 in total

1.  Restorative CAD/CAM materials in dentistry: analysis of their fluorescence properties and the applicability of the fluorescence-aided identification technique (FIT).

Authors:  Christian Klein; Matthias Krespach; Sebastian Spintzyk; Diana Wolff; Christiane von Ohle; Christian Meller
Journal:  Clin Oral Investig       Date:  2021-01-14       Impact factor: 3.573

2.  [Marginal features of CAD/CAM laminate veneers with different materials and thicknesses].

Authors:  Y Li; L Wong; X Q Liu; T Zhou; J Z Lyu; J G Tan
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2022-02-18

3.  Compressive strength evaluation of thin occlusal veneers from different CAD/CAM materials, before and after acidic saliva exposure.

Authors:  Codruța Ille; Elena-Alina Moacă; Daniel Pop; Luciana Goguță; Carmen Opriș; Ioana Ligia Pîrvulescu; Liane Avram; Andrei Faur; Anca Jivănescu
Journal:  Odontology       Date:  2022-09-12       Impact factor: 2.885

4.  Outcome of teeth restored with CAD/CAM zirconium dioxide post-cores: a retrospective study with a follow-up period of 3-6 years.

Authors:  Shunv Ying; Song Chen; Siyuan Wang; Lingli Xu; Xiaofeng Wang; Fuming He; Wei Liu
Journal:  BMC Oral Health       Date:  2022-06-16       Impact factor: 3.747

5.  External gap progression after cyclic fatigue of adhesive overlays and crowns made with high translucency zirconia or lithium silicate.

Authors:  Andrea Baldi; Allegra Comba; Giorgio Ferrero; Edoardo Italia; Riccardo Michelotto Tempesta; Gaetano Paolone; Annalisa Mazzoni; Lorenzo Breschi; Nicola Scotti
Journal:  J Esthet Restor Dent       Date:  2021-11-16       Impact factor: 3.040

6.  Resin Composite Materials for Chairside CAD/CAM Restorations: A Comparison of Selected Mechanical Properties.

Authors:  Wojciech Grzebieluch; Marcin Mikulewicz; Urszula Kaczmarek
Journal:  J Healthc Eng       Date:  2021-04-28       Impact factor: 2.682

7.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

8.  Influence of thickness and incisal extension of indirect veneers on the biomechanical behavior of maxillary canine teeth.

Authors:  Victória Luswarghi Souza Costa; João Paulo Mendes Tribst; Eduardo Shigueyuki Uemura; Dayana Campanelli de Morais; Alexandre Luiz Souto Borges
Journal:  Restor Dent Endod       Date:  2018-11-12

9.  New Intraoral Scanner-Based Chairside Measurement Method to Investigate the Internal Fit of Crowns: A Clinical Trial.

Authors:  Maximiliane Amelie Schlenz; Jonas Vogler; Alexander Schmidt; Peter Rehmann; Bernd Wöstmann
Journal:  Int J Environ Res Public Health       Date:  2020-03-25       Impact factor: 3.390

10.  Evaluation of the Surface Characteristics of Dental CAD/CAM Materials after Different Surface Treatments.

Authors:  Konstantinos Papadopoulos; Kimon Pahinis; Kyriaki Saltidou; Dimitrios Dionysopoulos; Effrosyni Tsitrou
Journal:  Materials (Basel)       Date:  2020-02-22       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.