Literature DB >> 24819532

Clinical marginal and internal adaptation of CAD/CAM milling, laser sintering, and cast metal ceramic crowns.

Ece Tamac1, Suna Toksavul2, Muhittin Toman3.   

Abstract

STATEMENT OF PROBLEM: Metal ceramic crowns are widely used in clinical practice, but comparisons of the clinical adaptation of restorations made with different processing techniques are lacking.
PURPOSE: The purpose of this study was to compare the clinical marginal and internal adaptation of metal ceramic crowns fabricated with 3 different techniques: computer-aided design and computer-aided manufacturing (CAD/CAM) milling (CCM), direct metal laser sintering (DMLS), and traditional casting (TC).
MATERIAL AND METHODS: Twenty CCM, 20 DMLS, and 20 TC metal ceramic crowns were fabricated for 42 patients. Before luting the crowns, silicone replicas were obtained to measure marginal gap and internal adaptation that was evaluated at 3 regions: axial wall, axio-occlusal angle, and occlusal surface. Measurements were made with a reflected light binocular stereomicroscope at 20× magnification and analyzed with 1-way analysis of variance (ANOVA) and the Bonferroni post hoc test (α=.05).
RESULTS: The mean marginal gap values were 86.64 μm for CCM, 96.23 μm for DMLS, and 75.92 μm for TC. The means at the axial wall region were 117.5 μm for the CCM group, 139.02 μm for the DMLS group, and 121.38 μm for the TC group. One-way ANOVA revealed no statistically significant differences among the groups for measurements at the marginal gap (P=.082) and the axial wall region (P=.114). The means at the axio-occlusal region were 142.1 μm for CCM, 188.12 μm for DMLS, and 140.63 μm for TC, and those at the occlusal surface region were 265.73 μm for CCM, 290.39 μm for DMLS, and 201.09 μm for TC. The mean values of group DMLS were significantly higher at the axio-occlusal region and the occlusal surface region than those of other groups (P<.05).
CONCLUSIONS: CCM, DMLS and TC metal ceramic crowns performed similarly in terms of clinical marginal and axial wall adaptation. The cement film thickness at the occlusal region and axio-occlusal region were higher for DMLS crowns.
Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24819532     DOI: 10.1016/j.prosdent.2013.12.020

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  Evaluation of the Marginal Fit of CAD/CAM Crowns Fabricated Using Two Different Chairside CAD/CAM Systems on Preparations of Varying Quality.

Authors:  Walter Renne; Bethany Wolf; Raymond Kessler; Karen McPherson; Anthony S Mennito
Journal:  J Esthet Restor Dent       Date:  2015-07-14       Impact factor: 2.843

2.  Fit of cobalt-chromium copings fabricated by the selective laser melting technology and casting method: A comparative evaluation using a profilometer.

Authors:  Koosha Gholamrezaei; Fariborz Vafaee; Behzad Fathi Afkari; Farnaz Firouz; Mozhgan Seif
Journal:  Dent Res J (Isfahan)       Date:  2020-05-23

3.  Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis.

Authors:  Jin-Young Park; So-Yeon Bae; Jae-Jun Lee; Ji-Hwan Kim; Hae-Young Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

4.  Comparative Evaluation of the Marginal Adaptation of Cast Ni-Cr Copings, Direct Metal Laser Sintering Co-Cr Copings, and Computer-aided Design and Computer-aided Manufacturing Zr Copings: An In-vitro Study.

Authors:  Lokanathanbalaji Doddy; Sesha Reddy; Sashideepth Reddy; Narendra R
Journal:  Cureus       Date:  2019-11-07

5.  Effect of the Use of Die Lubricant on the Marginal Fit of Wax Patterns.

Authors:  Ajinkya Wagh; Mahesh Gandhewar; Pankaj Pawar; Ashada Chavan; Snehal Kharwade; Anjali Mendhe; Devina Singh
Journal:  J Pharm Bioallied Sci       Date:  2021-11-10

6.  Comparison of Retention and Seating of Implant-Supported Hard and Soft Metal Copings.

Authors:  Safoura Ghodsi; Anahita Fayyazi; Maryam Ghiasi; Ahmad Rohanian; Marzieh Alikhasi
Journal:  Front Dent       Date:  2020-10-26

7.  Marginal and internal fit evaluation of conventional metal-ceramic versus zirconia CAD/CAM crowns.

Authors:  Nayana Paul; K N Raghavendra Swamy; M R Dhakshaini; Sanjukta Sowmya; M B Ravi
Journal:  J Clin Exp Dent       Date:  2020-01-01

8.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

9.  Comparison of prosthetic models produced by traditional and additive manufacturing methods.

Authors:  Jin-Young Park; Hae-Young Kim; Ji-Hwan Kim; Jae-Hong Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2015-08-18       Impact factor: 1.904

  9 in total