Literature DB >> 29724558

Marginal and internal fit of pre-sintered Co-Cr and zirconia 3-unit fixed dental prostheses as measured using microcomputed tomography.

Elie E Daou1, Hani Ounsi2, Mutlu Özcan3, Nadin Al-Haj Husain4, Ziad Salameh5.   

Abstract

STATEMENT OF PROBLEM: Limited information is available on the precision of new metal processing technologies.
PURPOSE: The purpose of this in vitro study was to evaluate the marginal and internal fit of pre-sintered cobalt-chromium (Co-Cr) and zirconia 3-unit fixed dental prostheses using x-ray microcomputed tomography.
MATERIAL AND METHODS: Three-unit fixed dental prostheses were prepared on metal dies (N=12) using a typodont model from the maxillary first premolar to the first molar. A standardized preparation with a 1.2-mm chamfer (360 degrees) and a 2-mm occlusal reduction was prepared on abutment teeth. The dies were scanned and divided into 2 groups to receive the fixed dental prostheses (n=6) made of pre-sintered Co-Cr and pre-sintered zirconia. Each framework was seated on its cast, and marginal and internal discrepancies were measured at 9 points, starting from the most distal point from the pontic for the maxillary first premolar and the first molar (points 1-4, mesial; point 5, occlusal; points 6-9, distal) of each abutment tooth using microcomputed tomography. The data were analyzed using the Levene test, t test, and ANOVA (α=.05).
RESULTS: When overall mean discrepancy values were compared, no significant difference was observed between pre-sintered Co-Cr and pre-sintered zirconia (P=.085). Discrepancy values for points 1, 2, and 3 were significantly different for pre-sintered Co-Cr and pre-sintered zirconia, with the lowest mean values for point 1 and the highest for point 5. On the abutment tooth basis, for the maxillary first premolar and the first molar, a significant difference was found only in points 6 (P<.001) and 8 (P<.003) for both materials. When the discrepancies for the maxillary first premolar were considered for pre-sintered Co-Cr and pre-sintered zirconia, the mean values were significantly different only at points 1 (P<.001), 2 (P=.007), and 3 (P=.003) and were smaller for pre-sintered zirconia. For the tooth the first molar, a significant difference was observed at point 2 (P=.002) and point 3 (P=.008) for both materials, where the mean values were higher for pre-sintered Co-Cr than for pre-sintered zirconia. The pairwise comparison between points showed a significant difference between measurement points within each material (P<.05). The increase in values between points 1 and 5 was evident for both pre-sintered Co-Cr and pre-sintered zirconia materials.
CONCLUSIONS: Three-unit fixed dental prostheses made of pre-sintered Co-Cr or zirconia showed similar marginal and internal discrepancy values, with the highest discrepancy values at the occlusal region in both the first premolar and first molar.
Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2018        PMID: 29724558     DOI: 10.1016/j.prosdent.2018.01.006

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  4 in total

1.  Survival and success rates of soft-milled cobalt-chromium-ceramic full-arch screw-retained implant-supported prostheses: a 2- to 7-year follow-up retrospective study.

Authors:  S Levartovsky; A Arieli; N Fridenberg; S Matalon; R Pilo
Journal:  Clin Oral Investig       Date:  2021-02-22       Impact factor: 3.573

Review 2.  New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies.

Authors:  Pinar Cevik; Martin Schimmel; Burak Yilmaz
Journal:  Biomed Res Int       Date:  2022-03-02       Impact factor: 3.411

3.  The Impact of Sintering Technology and Milling Technology on Fitting Titanium Crowns to Abutment Teeth-In Vitro Studies.

Authors:  Wojciech Ryniewicz; Łukasz Bojko; Anna M Ryniewicz
Journal:  Materials (Basel)       Date:  2022-08-24       Impact factor: 3.748

4.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.