Literature DB >> 31187767

In vitro marginal and internal adaptation of metal-ceramic crowns with cobalt-chrome and titanium framework fabricated with CAD/CAM and casting technique.

K Gurel1, S Toksavul1, M Toman1, E Tamac1.   

Abstract

AIM: The purpose of this study was to compare the marginal and internal fit of Co-Cr and titanium ceramic crowns fabricated with 2 different techniques: CAD/CAM milling and traditional casting (TC).
MATERIALS AND METHODS: Ten traditional casting of Co-Cr (TCC), 10 CAD/CAM milling of Co-Cr (MC), 10 traditional casting of titanium (TCT), 10 CAD/CAM milling of titanium ceramic crowns (MT) were fabricated. Silicone replicas were obtained to measure internal gap volume, marginal gap and internal adaptation that was evaluated at 3 regions: axial wall, axio-occlusal angle, and occlusal surface. Measurements were made with a X-ray micro computerized tomography (micro-CT) and analyzed with Bonferroni and Dunnet T3 post-hoc tests (α = 0.05).
RESULTS: One-way ANOVA revealed no statistically significant differences among the groups for measurements at the marginal gap (P > 0.05). At axial wall region the mean values of TCT group were higher than those of groups but only statistically not significant for TCC group (P < 0.05). TCC group statistically gives better results than MC group in axio-occlusal and occlusal regions (P < 0.05). The mean measurement of internal gap volume were 20.59 ± 0.83 mm3 for TCC, 22.73 ± 0.82 mm3 for MC, 22.83 ± 1.11 mm3 for TCT and 20.51 ± 1.16 mm3 for MT. Mean internal gap volume values MT group were smaller than those of groups but only statistically not significant for TCC group (P > 0.05).
CONCLUSION: All groups performed similar marginal adaptation. The cement film thickness at axio-occlusal angle point and occlusal region were higher for MC crowns.

Entities:  

Keywords:  CAD/CAM; casting; marginal and internal fit; titanium

Mesh:

Substances:

Year:  2019        PMID: 31187767     DOI: 10.4103/njcp.njcp_570_18

Source DB:  PubMed          Journal:  Niger J Clin Pract            Impact factor:   0.968


  4 in total

1.  Casting over Metal Method Used in Manufacturing Hybrid Cobalt-Chromium Dental Prosthetic Frameworks Assembles.

Authors:  Willi Andrei Uriciuc; Horatiu Vermesan; Ancuta Elena Tiuc; Aranka Ilea; Adina Bianca Bosca; Catalin Ovidiu Popa
Journal:  Materials (Basel)       Date:  2021-01-23       Impact factor: 3.623

2.  Comparison of internal fit of metal-ceramic crowns in CAD/CAM and lost-wax techniques in all fabrication stages through replica weighting, triple scanning, and scanning electron microscope.

Authors:  Sina Mohammadi Sadr; Elham Ahmadi; Masoumeh Hasani Tabatabaei; Saba Mohammadi; Faezeh Atri
Journal:  Clin Exp Dent Res       Date:  2022-02-20

3.  The Impact of Sintering Technology and Milling Technology on Fitting Titanium Crowns to Abutment Teeth-In Vitro Studies.

Authors:  Wojciech Ryniewicz; Łukasz Bojko; Anna M Ryniewicz
Journal:  Materials (Basel)       Date:  2022-08-24       Impact factor: 3.748

4.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.