Literature DB >> 27422236

Evaluation of the fit of metal ceramic restorations fabricated with a pre-sintered soft alloy.

Jong-Kyoung Park1, Hae-Young Kim2, Woong-Chul Kim3, Ji-Hwan Kim4.   

Abstract

STATEMENT OF PROBLEM: Fit is an important factor influencing the success or failure of restorations. Recently, there has been increasing use of a newly developed pre-sintered soft alloy for use in computer-aided design and computer-aided manufacturing (CAD-CAM) of cobalt-chromium alloys for the fabrication of metal ceramic restorations. However, almost no studies are available on the fit of restorations fabricated in this way.
PURPOSE: The purpose of this in vitro study was to evaluate the fit of metal coping fabricated from a newly developed CAD-CAM soft alloy in order to investigate its clinical applicability.
MATERIAL AND METHODS: Metal coping was categorized as casting alloy (CA), fully sintered hard alloy (FHA), or pre-sintered soft alloy (PSA) depending on the material, and 10 specimens of each category were fabricated. Seven measurement locations were selected in both the mesiodistal and labiolingual directions. For measurement of the marginal and internal discrepancies, silicone molds produced using a silicone replica technique were divided into mesiodistal and labiolingual cross-sections, and the width was measured. The Kruskal-Wallis and Mann-Whitney U test were performed (corrected α error level=.05/3).
RESULTS: The mean values of the total discrepancy were smallest in the CA group (52.53 ±33.40 μm) and largest in the FHA group (87.84 ±39.43 μm). The CA group and the PSA group were not significantly different from each other (P>.05) but were statistically significantly different from the FHA group (P<.001). In particular, the absolute marginal discrepancy did not differ significantly between the CA (33.68 ±8.44 μm) and PSA groups (37.01 ±8.04 μm) (P>.05).
CONCLUSIONS: The fit of the PSA restorations determined by this study was similar to that of conventional cast restorations. Both FHA and PSA restorations demonstrated clinically acceptable values (<120 μm). Copyright Â
© 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27422236     DOI: 10.1016/j.prosdent.2016.03.024

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Precision of the milled full-arch framework fabricated using pre-sintered soft alloy: A pilot study.

Authors:  Hyun-Wook Woo; Sung-Am Cho; Cheong-Hee Lee; Kyu-Bok Lee; Jin-Hyun Cho; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

2.  Evaluation of marginal discrepancy in metal frameworks fabricated by sintering-based computer-aided manufacturing methods.

Authors:  Necati Kaleli; Çağrı Ural; Yeşim Ölçer Us
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

3.  Comparative Study of the Fit Accuracy of Full-Arch Bar Frameworks Fabricated with Different Presintered Cobalt-Chromium Alloys.

Authors:  Hang-Nga Mai; Tae-Yub Kwon; Min-Ho Hong; Du-Hyeong Lee
Journal:  Biomed Res Int       Date:  2018-08-05       Impact factor: 3.411

4.  Marginal Discrepancy of Single Implant-Supported Metal Copings Fabricated by Various CAD/CAM and Conventional Techniques Using Different Materials.

Authors:  Safoura Ghodsi; Marzieh Alikhasi; Nika Soltani
Journal:  Eur J Dent       Date:  2019-11-26

5.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

Review 6.  A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses.

Authors:  Per Svanborg; Lars Hjalmarsson
Journal:  Biomater Investig Dent       Date:  2020-01-20

7.  Comparative clinical study of the marginal discrepancy of fixed dental prosthesis fabricated by the milling-sintering method using a presintered alloy.

Authors:  Mijoo Kim; Jaewon Kim; Hang-Nga Mai; Tae-Yub Kwon; Yong-Do Choi; Cheong-Hee Lee; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2019-10-30       Impact factor: 1.904

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.