PURPOSE: In previous work, the authors developed and demonstrated the concept of an image reconstruction procedure aimed to unify gated and dynamic nuclear cardiac imaging, which the authors have termed five-dimensional (5D) SPECT. Gated imaging permits the clinician to evaluate wall motion and, through the use of stress and rest scans, allows perfusion defects to be observed. Dynamic imaging depicts kinetics in the myocardium, which can be used to evaluate perfusion, but traditional dynamic images are motionless and do not depict wall motion. In this article, the authors investigate the degree to which perfusion defects can be detected from the dynamic information conveyed by 5D images, a problem that is particularly challenging in the absence of multiple fast camera rotations.
METHODS: The authors first demonstrate the usefulness of dynamic reconstructed images for perfusion detection by using linear discriminant analyses (Fisher linear discriminant analysis and principal component analysis) and a numerical channelized Hotelling observer. The authors then derive three types of discriminant metrics for characterizing the temporal kinetic information in reconstructed dynamic images for differentiating perfusion defects from normal cardiac perfusion, which are the Fisher linear discriminant map, temporal derivative map, and kinetic parametric images.
RESULTS: Results are based on the NURBS-based cardiac-torso phantom with simulation of Tc99m-teboroxime as the imaging agent. The derived metric maps and quantitative contrast-to-noise ratio results demonstrate that the reconstructed dynamic images could yield higher detectability of the perfusion defect than conventional gated reconstruction while providing wall motion information simultaneously.
CONCLUSIONS: The proposed metrics can be used to produce new types of visualizations, showing wall motion and perfusion information, that may potentially be useful for clinical evaluation. Since 5D imaging permits wall motion and kinetics to be observed simultaneously, it may ultimately obviate the need for separate stress and rest scans.

Entities:  

Mesh:

Year:  2010        PMID: 20964230      PMCID: PMC2945746          DOI: 10.1118/1.3481507

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  22 in total

Review 1.  Fast spatio-temporal image reconstruction for dynamic PET.

Authors:  M N Wernick; E J Infusino; M Milosević
Journal:  IEEE Trans Med Imaging       Date:  1999-03       Impact factor: 10.048

2.  Spatiotemporal reconstruction of list-mode PET data.

Authors:  Thomas E Nichols; Jinyi Qi; Evren Asma; Richard M Leahy
Journal:  IEEE Trans Med Imaging       Date:  2002-04       Impact factor: 10.048

3.  Reconstruction of dynamic gated cardiac SPECT.

Authors:  Mingwu Jin; Yongyi Yang; Michael A King
Journal:  Med Phys       Date:  2006-11       Impact factor: 4.071

4.  Fully 4D motion-compensated reconstruction of cardiac SPECT images.

Authors:  Erwan Gravier; Yongyi Yang; Michael A King; Mingwu Jin
Journal:  Phys Med Biol       Date:  2006-08-30       Impact factor: 3.609

5.  Convergence of EM image reconstruction algorithms with Gibbs smoothing.

Authors:  K Lange
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

6.  Experimental verification of technetium 99m-labeled teboroxime kinetic parameters in the myocardium with dynamic single-photon emission computed tomography: reproducibility, correlation to flow, and susceptibility to extravascular contamination.

Authors:  A M Smith; G T Gullberg; P E Christian
Journal:  J Nucl Cardiol       Date:  1996 Mar-Apr       Impact factor: 5.952

7.  Block-iterative techniques for fast 4D reconstruction using a priori motion models in gated cardiac SPECT.

Authors:  D S Lalush; B M Tsui
Journal:  Phys Med Biol       Date:  1998-04       Impact factor: 3.609

8.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

9.  Rapid back to back adenosine stress/rest technetium-99m teboroxime myocardial perfusion SPECT using a triple-detector camera.

Authors:  T Chua; H Kiat; G Germano; K Takemoto; G Fernandez; Y Biasio; J Friedman; D Berman
Journal:  J Nucl Med       Date:  1993-09       Impact factor: 10.057

10.  Clinical utility of technetium-99m-teboroxime myocardial washout imaging.

Authors:  M J Henzlova; J Machac
Journal:  J Nucl Med       Date:  1994-04       Impact factor: 10.057

View more
  4 in total

1.  Preconditioned alternating projection algorithm for solving the penalized-likelihood SPECT reconstruction problem.

Authors:  Si Li; Jiahan Zhang; Andrzej Krol; C Ross Schmidtlein; David Feiglin; Yuesheng Xu
Journal:  Phys Med       Date:  2017-05-09       Impact factor: 2.685

2.  Comparison study of temporal regularization methods for fully 5D reconstruction of cardiac gated dynamic SPECT.

Authors:  Xiaofeng Niu; Yongyi Yang; Michael A King
Journal:  Phys Med Biol       Date:  2012-08-08       Impact factor: 3.609

3.  Effective noise-suppressed and artifact-reduced reconstruction of SPECT data using a preconditioned alternating projection algorithm.

Authors:  Si Li; Jiahan Zhang; Andrzej Krol; C Ross Schmidtlein; Levon Vogelsang; Lixin Shen; Edward Lipson; David Feiglin; Yuesheng Xu
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

4.  The performance of MLEM for dynamic imaging from simulated few-view, multi-pinhole SPECT.

Authors:  Dan Ma; Paul Wolf; Anne V Clough; Taly Gilat Schmidt
Journal:  IEEE Trans Nucl Sci       Date:  2013-02       Impact factor: 1.679

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.