New Theoretical Results on Channelized Hotelling Observer Performance Estimation with Known Difference of Class Means.

Adam Wunderlich1, Frédéric Noo1.   

Abstract

Task-based assessments of image quality constitute a rigorous, principled approach to the evaluation of imaging system performance. To conduct such assessments, it has been recognized that mathematical model observers are very useful, particularly for purposes of imaging system development and optimization. One type of model observer that has been widely applied in the medical imaging community is the channelized Hotelling observer (CHO). Since estimates of CHO performance typically include statistical variability, it is important to control and limit this variability to maximize the statistical power of image-quality studies. In a previous paper, we demonstrated that by including prior knowledge of the image class means, a large decrease in the bias and variance of CHO performance estimates can be realized. The purpose of the present work is to present refinements and extensions of the estimation theory given in our previous paper, which was limited to point estimation with equal numbers of images from each class. Specifically, we present and characterize minimum-variance unbiased point estimators for observer signal-to-noise ratio (SNR) that allow for unequal numbers of lesion-absent and lesion-present images. Building on this SNR point estimation theory, we then show that confidence intervals with exactly-known coverage probabilities can be constructed for commonly-used CHO performance measures. Moreover, we propose simple, approximate confidence intervals for CHO performance, and we show that they are well-behaved in most scenarios of interest.

Entities:  

Keywords:  AUC; image quality assessment; model observer; receiver operating characteristic (ROC); signal-to-noise ratio (SNR)

Year:  2013        PMID: 24436497      PMCID: PMC3891002          DOI: 10.1109/TNS.2012.2227340

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  28 in total

1.  An approach for balancing diagnostic image quality with cancer risk: application to pediatric diagnostic imaging of 99mTc-dimercaptosuccinic acid.

Authors:  George Sgouros; Eric C Frey; Wesley E Bolch; Michael B Wayson; Andres F Abadia; S Ted Treves
Journal:  J Nucl Med       Date:  2011-12       Impact factor: 10.057

2.  Noise properties of the EM algorithm: II. Monte Carlo simulations.

Authors:  D W Wilson; B M Tsui; H H Barrett
Journal:  Phys Med Biol       Date:  1994-05       Impact factor: 3.609

3.  Hardware assessment using the multi-module, multi-resolution system (M3R): a signal-detection study.

Authors:  Jacob Y Hesterman; Matthew A Kupinski; Eric Clarkson; Harrison H Barrett
Journal:  Med Phys       Date:  2007-07       Impact factor: 4.071

4.  A channelized Hotelling observer study of lesion detection in SPECT MAP reconstruction using anatomical priors.

Authors:  S Kulkarni; P Khurd; I Hsiao; L Zhou; G Gindi
Journal:  Phys Med Biol       Date:  2007-05-23       Impact factor: 3.609

5.  Estimation of channelized hotelling observer performance with known class means or known difference of class means.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Med Imaging       Date:  2009-01-19       Impact factor: 10.048

6.  Detection performance analysis for time-of-flight PET.

Authors:  Nannan Cao; Ronald H Huesman; William W Moses; Jinyi Qi
Journal:  Phys Med Biol       Date:  2010-11-03       Impact factor: 3.609

7.  Addition of a channel mechanism to the ideal-observer model.

Authors:  K J Myers; H H Barrett
Journal:  J Opt Soc Am A       Date:  1987-12       Impact factor: 2.129

8.  The effect of nonlinear human visual system components on performance of a channelized Hotelling observer in structured backgrounds.

Authors:  Yani Zhang; Binh T Pham; Miguel P Eckstein
Journal:  IEEE Trans Med Imaging       Date:  2006-10       Impact factor: 10.048

9.  Optimization of Rb-82 PET acquisition and reconstruction protocols for myocardial perfusion defect detection.

Authors:  Jing Tang; Arman Rahmim; Riikka Lautamäki; Martin A Lodge; Frank M Bengel; Benjamin M W Tsui
Journal:  Phys Med Biol       Date:  2009-05-06       Impact factor: 3.609

10.  Realistic CT simulation using the 4D XCAT phantom.

Authors:  W P Segars; M Mahesh; T J Beck; E C Frey; B M W Tsui
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

View more
  5 in total

1.  Factors affecting the normality of channel outputs of channelized model observers: an investigation using realistic myocardial perfusion SPECT images.

Authors:  Fatma E A Elshahaby; Michael Ghaly; Abhinav K Jha; Eric C Frey
Journal:  J Med Imaging (Bellingham)       Date:  2016-01-28

2.  Exact confidence intervals for channelized Hotelling observer performance in image quality studies.

Authors:  Adam Wunderlich; Frederic Noo; Brandon D Gallas; Marta E Heilbrun
Journal:  IEEE Trans Med Imaging       Date:  2014-09-26       Impact factor: 10.048

3.  Task-based detectability in CT image reconstruction by filtered backprojection and penalized likelihood estimation.

Authors:  Grace J Gang; J Webster Stayman; Wojciech Zbijewski; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2014-08       Impact factor: 4.071

4.  Region of interest based Hotelling observer for computed tomography with comparison to alternative methods.

Authors:  Adrian A Sanchez; Emil Y Sidky; Xiaochuan Pan
Journal:  J Med Imaging (Bellingham)       Date:  2014-12-08

Review 5.  Model observers in medical imaging research.

Authors:  Xin He; Subok Park
Journal:  Theranostics       Date:  2013-10-04       Impact factor: 11.556

  5 in total