Literature DB >> 34230587

Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations.

Keunbada Son1,2, Young-Tak Son1,2, Ji-Min Lee2, Kyu-Bok Lee3,4.   

Abstract

This study evaluated the marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation scanned at four finish line locations. The right maxillary first molar tooth preparation model was fabricated using a ceramic material and placed in four finish line locations (supragingival, equigingival, subgingival, and subgingival with a cord). Intraoral scanning was performed. Crowns were designed based on the scanned area. Interim crowns were fabricated using a stereolithography three-dimensional (3D) printer (N = 16 per location). Marginal and internal fit were evaluated with a silicone replica technique. Intaglio surface trueness was evaluated using a 3D inspection software. One-way analysis of variance and Tukey HSD test were performed for comparisons (α = 0.05). The marginal and internal fit showed significant differences according to locations (P < 0.05); the marginal fit showed the best results in the supragingival finish line (P < 0.05). Intaglio surface trueness was significantly different in the marginal region, with the highest value in the subgingival location (P < 0.05). Crowns fabricated on the subgingival finish line caused inaccurate marginal fit due to poor fabrication reproducibility of the marginal region. The use of an intraoral scanner should be decided on the clinical situation and needs.

Entities:  

Year:  2021        PMID: 34230587     DOI: 10.1038/s41598-021-93455-7

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  27 in total

1.  Marginal gap, internal fit, and fracture load of leucite-reinforced ceramic inlays fabricated by CEREC inLab and hot-pressed techniques.

Authors:  Alireza Keshvad; Tabassom Hooshmand; Farokh Asefzadeh; Foroogh Khalilinejad; Mohammad Alihemmati; Richard Van Noort
Journal:  J Prosthodont       Date:  2011-08-01       Impact factor: 2.752

2.  Accuracy of a chairside intraoral scanner compared with a laboratory scanner for the completely edentulous maxilla: An in vitro 3-dimensional comparative analysis.

Authors:  Fernando Zarone; Gennaro Ruggiero; Marco Ferrari; Francesco Mangano; Tim Joda; Roberto Sorrentino
Journal:  J Prosthet Dent       Date:  2020-10-24       Impact factor: 3.426

3.  Assessment of the Adaptation of Interim Crowns using Different Measurement Techniques.

Authors:  Chin-Chun Peng; Kwok-Hung Chung; Van Ramos
Journal:  J Prosthodont       Date:  2019-11-08       Impact factor: 2.752

4.  Marginal and internal fit of metal copings fabricated with rapid prototyping and conventional waxing.

Authors:  Ehsan Farjood; Mahroo Vojdani; Kiyanoosh Torabi; Amir Ali Reza Khaledi
Journal:  J Prosthet Dent       Date:  2016-07-25       Impact factor: 3.426

5.  Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression.

Authors:  Ting-Shu Su; Jian Sun
Journal:  J Prosthet Dent       Date:  2016-04-07       Impact factor: 3.426

6.  SEM evaluation of the precision of fit of CAD/CAM zirconia and metal-ceramic posterior crowns.

Authors:  Rocio Ortega; Esther Gonzalo; Miguel Gomez-Polo; Carlos Lopez-Suarez; Maria J Suarez
Journal:  Dent Mater J       Date:  2017-03-29       Impact factor: 2.102

7.  Comparison of marginal and internal fit of 3-unit zirconia frameworks fabricated with CAD-CAM technology using direct and indirect digital scans.

Authors:  Ali Arezoobakhsh; Sayed Shojaedin Shayegh; Ali Jamali Ghomi; Seyed Mohammad Reza Hakimaneh
Journal:  J Prosthet Dent       Date:  2019-04-11       Impact factor: 3.426

8.  Micro-CT evaluation of marginal and internal fit of cemented polymer infiltrated ceramic network material crowns manufactured after conventional and digital impressions.

Authors:  Rinet Dauti; Barbara Cvikl; Bledar Lilaj; Patrick Heimel; Andreas Moritz; Andreas Schedle
Journal:  J Prosthodont Res       Date:  2018-06-08       Impact factor: 4.642

9.  Evaluation of the Marginal and Internal Fit of Implant-Supported Metal Copings Fabricated with 3 Different Techniques: An In Vitro Study.

Authors:  Bengisu Yildirim; Gamze Paken
Journal:  J Prosthodont       Date:  2019-02-03       Impact factor: 2.752

10.  CAD/CAM or conventional ceramic materials restorations longevity: a systematic review and meta-analysis.

Authors:  Stéfani Becker Rodrigues; Patrícia Franken; Roger Keller Celeste; Vicente Castelo Branco Leitune; Fabrício Mezzomo Collares
Journal:  J Prosthodont Res       Date:  2019-07-11       Impact factor: 4.642

View more
  3 in total

1.  How Does the Use of an Intraoral Scanner Affect Muscle Fatigue? A Preliminary In Vivo Study.

Authors:  KeunBaDa Son; Ji-Min Lee; Young-Tak Son; Jin-Wook Kim; Myoung-Uk Jin; Kyu-Bok Lee
Journal:  Bioengineering (Basel)       Date:  2022-08-01

2.  Trueness of 3D printed partial denture frameworks: build orientations and support structure density parameters.

Authors:  Mostafa Omran Hussein; Lamis Ahmed Hussein
Journal:  J Adv Prosthodont       Date:  2022-06-27       Impact factor: 1.989

3.  Optimization of Digital Light Processing Three-Dimensional Printing of the Removable Partial Denture Frameworks; The Role of Build Angle and Support Structure Diameter.

Authors:  Mostafa Omran Hussein; Lamis Ahmed Hussein
Journal:  Materials (Basel)       Date:  2022-03-21       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.