Literature DB >> 30982618

Comparison of marginal and internal fit of 3-unit zirconia frameworks fabricated with CAD-CAM technology using direct and indirect digital scans.

Ali Arezoobakhsh1, Sayed Shojaedin Shayegh2, Ali Jamali Ghomi3, Seyed Mohammad Reza Hakimaneh4.   

Abstract

STATEMENT OF PROBLEM: Accurate marginal and internal fit of dental restorations are essential for their long-term success. The fit of zirconia restorations prepared using digital scan systems has not been fully evaluated.
PURPOSE: The purpose of this in vitro study was to compare the marginal and internal fit of 3-unit zirconia frameworks fabricated using direct and indirect digital scans.
MATERIAL AND METHODS: In a maxillary model, the left first premolar and first molar were prepared to receive 3-unit zirconia fixed dental prostheses. Conventional impressions were made using stock trays and 2-step putty/wash polyvinyl siloxane material and were scanned using laboratory scanner (Conventional Impression-Laboratory scanner [CIL] group). The impressions were then poured, and the stone casts were scanned (Dental Cast-Laboratory scanner [DCL] group). Digital scans were made using TRIOS (TRIOS Intraoral scanner [TRI] group) and CS3600 (CS3600 Intraoral scanner [CSI] group) scanners (n=10). Zirconia copings were designed and milled from presintered blocks and subsequently sintered. Marginal, mid-axial, axio-occlusal, and mid-occlusal discrepancies were measured using the silicone replica technique with stereomicroscopy at ×50 magnification. The data were analyzed using 1-way ANOVA (α=.01).
RESULTS: The ANOVA revealed significant differences among the studied groups in terms of all studied characteristics (P≤.01). Marginal gap was significantly higher in the DCL group (106 ±45 μm) compared with all other groups (P≤.01). However, no significant differences were observed in marginal gap between the TRI (60 ±15 μm) and CSI (55 ±13 μm) groups (P>.01). Internal gap in the mid-occlusal and axio-occlusal regions were significantly higher in the CIL (238 ±92 μm and 227 ±95 μm) and DCL (248 ±71 μm and 216 ±68 μm) groups than those recorded in the TRI (104 ±27 μm and 126 ±31 μm) and CSI (128 ±16 μm and 147 ±28 μm) groups (P≤.01). Internal discrepancies in the mid-axial position were similar between the TRI (70 ±15 μm) and CSI (72 ±23 μm) groups (P>.01), but these values were significantly lower than those recorded in the CIL (88 ±31 μm) and DCL (85 ±30 μm) groups (P≤.01).
CONCLUSIONS: Within the limitations of this study, zirconia frameworks in the TRI and CSI groups had lower marginal and internal gaps compared with those in the DCL and CIL groups. Marginal gap in all groups was within a clinically acceptable range.
Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Year:  2019        PMID: 30982618     DOI: 10.1016/j.prosdent.2018.10.023

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Effect of the volumetric dimensions of a complete arch on the accuracy of scanners.

Authors:  Min-Kyu Kim; KeunBaDa Son; Beom-Young Yu; Kyu-Bok Lee
Journal:  J Adv Prosthodont       Date:  2020-12-28       Impact factor: 1.904

2.  In-vitro evaluation of marginal and internal fit of 3-unit monolithic zirconia restorations fabricated using digital scanning technologies.

Authors:  Çise Özal; Mutahhar Ulusoy
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

3.  Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans.

Authors:  Irem Gokce Uluc; Mustafa Baris Guncu; Guliz Aktas; Ilser Turkyilmaz
Journal:  J Dent Sci       Date:  2021-07-30       Impact factor: 2.080

4.  A Comparative Study of Additive and Subtractive Manufacturing Techniques for a Zirconia Dental Product: An Analysis of the Manufacturing Accuracy and the Bond Strength of Porcelain to Zirconia.

Authors:  Joon-Mo Moon; Chang-Sub Jeong; Hee-Jeong Lee; Ji-Myung Bae; Eun-Joo Choi; Sung-Tae Kim; Young-Bum Park; Seung-Han Oh
Journal:  Materials (Basel)       Date:  2022-08-05       Impact factor: 3.748

5.  Comparison of marginal and internal fit of three-unit implant-supported fixed prosthetic substructures fabricated using CAD/CAM systems.

Authors:  Ozlem Kayikci; Sabit Melih Ates
Journal:  Clin Oral Investig       Date:  2021-07-31       Impact factor: 3.573

6.  Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations.

Authors:  Keunbada Son; Young-Tak Son; Ji-Min Lee; Kyu-Bok Lee
Journal:  Sci Rep       Date:  2021-07-06       Impact factor: 4.379

7.  Effect of Tooth Types on the Accuracy of Dental 3D Scanners: An In Vitro Study.

Authors:  Keunbada Son; Kyu-Bok Lee
Journal:  Materials (Basel)       Date:  2020-04-09       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.