Literature DB >> 27061628

Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression.

Ting-Shu Su1, Jian Sun2.   

Abstract

STATEMENT OF PROBLEM: For 20 years, the intraoral digital impression technique has been applied to the fabrication of computer aided design and computer aided manufacturing (CAD-CAM) fixed dental prostheses (FDPs). Clinical fit is one of the main determinants of the success of an FDP. Studies of the clinical fit of 3-unit ceramic FDPs made by means of a conventional impression versus a digital impression technology are limited.
PURPOSE: The purpose of this in vitro study was to evaluate and compare the internal fit and marginal fit of CAD-CAM, 3-unit ceramic FDP frameworks fabricated from an intraoral digital impression and a conventional impression.
MATERIAL AND METHODS: A standard model was designed for a prepared maxillary left canine and second premolar and missing first premolar. The model was scanned with an intraoral digital scanner, exporting stereolithography (STL) files as the experimental group (digital group). The model was used to fabricate 10 stone casts that were scanned with an extraoral scanner, exporting STL files to a computer connected to the scanner as the control group (conventional group). The STL files were used to produce zirconia FDP frameworks with CAD-CAM. These frameworks were seated on the standard model and evaluated for marginal and internal fit. Each framework was segmented into 4 sections per abutment teeth, resulting in 8 sections per framework, and was observed using optical microscopy with ×50 magnification. Four measurement points were selected on each section as marginal discrepancy (P1), mid-axial wall (P2), axio-occusal edge (P3), and central-occlusal point (P4).
RESULTS: Mean marginal fit values of the digital group (64 ±16 μm) were significantly smaller than those of the conventional group (76 ±18 μm) (P<.05). The mean internal fit values of the digital group (111 ±34 μm) were significantly smaller than those of the conventional group (132 ±44 μm) (P<.05).
CONCLUSIONS: CAD-CAM 3-unit zirconia FDP frameworks fabricated from intraoral digital and conventional impressions showed clinically acceptable marginal and internal fit. The marginal and internal fit of frameworks fabricated from the intraoral digital impression system were better than those fabricated from conventional impressions.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27061628     DOI: 10.1016/j.prosdent.2016.01.018

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  13 in total

1.  Assessment of different types of intra oral scanners and 3D printers on the accuracy of printed models: An in vitro study.

Authors:  Fernando Igai; Washington-Steagall Junior; Carolina-Mayumi Iegami; Pedro-Tortamano Neto
Journal:  J Clin Exp Dent       Date:  2021-12-01

2.  Comparison of Digital and Conventional Impression Methods by Preclinical Students: Efficiency and Future Expectations.

Authors:  Halenur Bilir; Ceren Ayguzen
Journal:  J Int Soc Prev Community Dent       Date:  2020-08-06

Review 3.  Intraoral scanners in dentistry: a review of the current literature.

Authors:  Francesco Mangano; Andrea Gandolfi; Giuseppe Luongo; Silvia Logozzo
Journal:  BMC Oral Health       Date:  2017-12-12       Impact factor: 2.757

4.  In vivo evaluation of inter-operator reproducibility of digital dental and conventional impression techniques.

Authors:  Emi Kamimura; Shinpei Tanaka; Masayuki Takaba; Keita Tachi; Kazuyoshi Baba
Journal:  PLoS One       Date:  2017-06-21       Impact factor: 3.240

Review 5.  A systematic review on the accuracy of zirconia crowns and fixed dental prostheses.

Authors:  Per Svanborg
Journal:  Biomater Investig Dent       Date:  2020-01-07

6.  Evaluation of Mechanical and Physical Properties of Light and Heat Polymerized UDMA for DLP 3D Printer.

Authors:  Qutaiba Alsandi; Masaomi Ikeda; Yoshinori Arisaka; Toru Nikaido; Yumi Tsuchida; Alireza Sadr; Nobuhiko Yui; Junji Tagami
Journal:  Sensors (Basel)       Date:  2021-05-11       Impact factor: 3.576

7.  Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations.

Authors:  Keunbada Son; Young-Tak Son; Ji-Min Lee; Kyu-Bok Lee
Journal:  Sci Rep       Date:  2021-07-06       Impact factor: 4.379

Review 8.  Accuracy of marginal adaptation of posterior fixed dental prosthesis made from digital impression technique: A systematic review.

Authors:  Hanuman Chalapathi Kumar; Tannamala Pavan Kumar; Surapaneni Hemchand; Chinni Suneelkumar; Anirudhan Subha
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07

Review 9.  Accuracy of an intraoral digital impression: A review.

Authors:  Kanchan Aswani; Sattyam Wankhade; Arun Khalikar; Suryakant Deogade
Journal:  J Indian Prosthodont Soc       Date:  2020-01-27

10.  Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques.

Authors:  Hasan Kocaağaoğlu; Haydar Albayrak; Sezgi Cinel Sahin; Ayşegül Güleryüz Gürbulak
Journal:  J Adv Prosthodont       Date:  2019-10-30       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.