Literature DB >> 21806704

Marginal gap, internal fit, and fracture load of leucite-reinforced ceramic inlays fabricated by CEREC inLab and hot-pressed techniques.

Alireza Keshvad1, Tabassom Hooshmand, Farokh Asefzadeh, Foroogh Khalilinejad, Mohammad Alihemmati, Richard Van Noort.   

Abstract

PURPOSE: This in vitro study was designed to evaluate and compare the marginal gap, internal fit, and fracture load of resin-bonded, leucite-reinforced glass ceramic mesio-occlusal-distal (MOD) inlays fabricated by computer-aided design/manufacturing (CAD/CAM) or hot pressing.
MATERIALS AND METHODS: Fifty caries-free extracted human molars were prepared for standardized MOD inlays. Impressions of each specimen were made and poured using type IV dental stone. Dies were randomly divided into two equal groups. Twenty-five ceramic inlays were fabricated by the hot-pressed technique using IPS Empress leucite-reinforced glass ceramics, and the other 25 ceramic inlays were produced by CAD/CAM technology using ProCAD leucite-reinforced ceramic blocks and CEREC inLab facilities. Inlays were bonded to the teeth using a dual-cured resin cement. The specimens were stored in distilled water at 37°C for 24 hours and then thermocycled for 5000 cycles. The marginal gap measurements were taken with a stereomicroscope. Specimens in each group of inlay systems were randomly divided into two subgroups of 10 and 15 specimens each. Ten specimens in each subgroup were sectioned mesiodistally for evaluation of the internal fit. The fracture load of specimens in the second subgroup (n = 15) of the two inlay systems was determined under compressive load in a universal testing machine. Data were analyzed using Student's t-test at a significance level of p < 0.05.
RESULTS: The mean marginal and internal gap size in both IPS Empress and ProCAD inlays were less than 100 μm; however, the marginal gap for the IPS Empress restorations was significantly higher than that of ProCAD restorations (p < 0.05). There was no significant difference in the mean internal fit or the fracture load between the two glass ceramic inlays (p > 0.05).
CONCLUSIONS: The leucite-reinforced glass ceramic inlay restorations fabricated by CEREC inLab (CAD/CAM) and the hot-pressed technique provided clinically acceptable marginal and internal fit with comparable fracture loads after luting.
© 2011 by The American College of Prosthodontists.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21806704     DOI: 10.1111/j.1532-849X.2011.00745.x

Source DB:  PubMed          Journal:  J Prosthodont        ISSN: 1059-941X            Impact factor:   2.752


  15 in total

1.  Evaluation of the Marginal Fit of CAD/CAM Crowns Fabricated Using Two Different Chairside CAD/CAM Systems on Preparations of Varying Quality.

Authors:  Walter Renne; Bethany Wolf; Raymond Kessler; Karen McPherson; Anthony S Mennito
Journal:  J Esthet Restor Dent       Date:  2015-07-14       Impact factor: 2.843

2.  Marginal and internal fit of heat pressed versus CAD/CAM fabricated all-ceramic onlays after exposure to thermo-mechanical fatigue.

Authors:  Petra C Guess; Thaleia Vagkopoulou; Yu Zhang; Martin Wolkewitz; Joerg R Strub
Journal:  J Dent       Date:  2013-10-24       Impact factor: 4.379

3.  Comparison of marginal adaptation and internal fit of monolithic lithium disilicate crowns produced by 4 different CAD/CAM systems.

Authors:  Brunna Mota Ferrairo; Fernanda Furtado Piras; Feranda Ferruzzi Lima; Heitor Marques Honório; Marco Antonio Hungaro Duarte; Ana Flávia Sanches Borges; José Henrique Rubo
Journal:  Clin Oral Investig       Date:  2020-08-11       Impact factor: 3.573

4.  Comparison of microleakage and thickness of resin cement in ceramic inlays with various temperatures.

Authors:  Homayoun Alaghemand; Faezeh Abolghasemzadeh; Farzaneh Pakdel; Reza Judi Chelan
Journal:  J Dent Res Dent Clin Dent Prospects       Date:  2014-03-05

5.  Accuracy and reproducibility of 3D digital tooth preparations made by gypsum materials of various colors.

Authors:  Fa-Bing Tan; Chao Wang; Hong-Wei Dai; Yu-Bo Fan; Jin-Lin Song
Journal:  J Adv Prosthodont       Date:  2018-02-12       Impact factor: 1.904

6.  Comparative Evaluation of Marginal Adaptation and Fracture Strength of Different Ceramic Inlays Produced by CEREC Omnicam and Heat-Pressed Technique.

Authors:  F D Oz; S Bolay
Journal:  Int J Dent       Date:  2018-04-26

7.  Influence of Preparation Reconstruction on the Compressive Strength of CAD/CAM Ceramic Inlays.

Authors:  Bruna Salamoni Sinhori; Luiz Clovis Cardoso Vieira; Luiz Narciso Baratieri
Journal:  Int J Biomater       Date:  2019-01-01

8.  Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations.

Authors:  Keunbada Son; Young-Tak Son; Ji-Min Lee; Kyu-Bok Lee
Journal:  Sci Rep       Date:  2021-07-06       Impact factor: 4.379

9.  Effect of software version and parameter settings on the marginal and internal adaptation of crowns fabricated with the CAD/CAM system.

Authors:  Ji Suk Shim; Jin Sook Lee; Jeong Yol Lee; Yeon Jo Choi; Sang Wan Shin; Jae Jun Ryu
Journal:  J Appl Oral Sci       Date:  2015-10       Impact factor: 2.698

10.  Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study.

Authors:  Afra Hassan Elrashid; Amjad Hamod AlKahtani; Shatha Jarallah Alqahtani; Nouf Bati Alajmi; Fatimah Hussain Alsultan
Journal:  J Int Soc Prev Community Dent       Date:  2019-02-13
View more