Literature DB >> 28367911

SEM evaluation of the precision of fit of CAD/CAM zirconia and metal-ceramic posterior crowns.

Rocio Ortega1, Esther Gonzalo1, Miguel Gomez-Polo1, Carlos Lopez-Suarez1, Maria J Suarez1.   

Abstract

The purpose of this study is to evaluate the precision of fit of posterior crowns made from three commercial CAD/CAM zirconia ceramics and conventional metal-ceramic technique. The external and internal marginal fit of the crowns was evaluated using direct SEM-based measurements. The data were subjected to Kruskal-Wallis, multicomparison post hoc analysis and Wilcoxon rank sum tests (α=0.05). Significant differences were observed for the external (p<0.002) and the internal (p<0.0001) marginal evaluation among the groups. No differences were observed between the buccal and lingual surfaces for the external (p=0.34) and internal (p=0.55) evaluations. No differences were showed between the external and internal measurements (p=0.37). The accuracy of fit was within the range of clinical acceptance. The lowest discrepancies corresponded to the NobelProcera group for external (39.3±11.81 μm) and internal (41.09±7.54 µm) marginal fit. The results confirmed that destructive methods are not required to assess the marginal fit of dental prosthetic crowns.

Entities:  

Keywords:  CAD/CAM; External marginal fit; Internal marginal fit; Measurement techniques; Zirconia

Mesh:

Substances:

Year:  2017        PMID: 28367911     DOI: 10.4012/dmj.2016-305

Source DB:  PubMed          Journal:  Dent Mater J        ISSN: 0287-4547            Impact factor:   2.102


  5 in total

1.  Effect of Erbium, Chromium-doped: Yttrium, Scandium, Gallium and Garnet Laser Tooth Preparation on Gap Formation of Universal Adhesive Bonded to Enamel and Dentin: A Micro-CT and SEM Study.

Authors:  Anfal AlQussier; Wedad Awliya
Journal:  J Lasers Med Sci       Date:  2022-03-27

2.  Microleakage around zirconia crown margins after ultrasonic scaling with self-adhesive resin or resin modified glass ionomer cement.

Authors:  Bright Chang; Ronald Goldstein; Chee Paul Lin; Sudha Byreddy; Nathaniel C Lawson
Journal:  J Esthet Restor Dent       Date:  2017-12-01       Impact factor: 2.843

Review 3.  Fit of tooth-supported zirconia single crowns-A systematic review of the literature.

Authors:  Walaa Magdy Ahmed; Batoul Shariati; Arwa Z Gazzaz; Mohammed E Sayed; Ricardo M Carvalho
Journal:  Clin Exp Dent Res       Date:  2020-09-03

4.  Marginal and internal fit and intaglio surface trueness of interim crowns fabricated from tooth preparation of four finish line locations.

Authors:  Keunbada Son; Young-Tak Son; Ji-Min Lee; Kyu-Bok Lee
Journal:  Sci Rep       Date:  2021-07-06       Impact factor: 4.379

5.  Stereomicroscopic Evaluation of Marginal Fit of E.Max Press and E.Max Computer-Aided Design and Computer-Assisted Manufacturing Lithium Disilicate Ceramic Crowns: An In vitro Study.

Authors:  Afra Hassan Elrashid; Amjad Hamod AlKahtani; Shatha Jarallah Alqahtani; Nouf Bati Alajmi; Fatimah Hussain Alsultan
Journal:  J Int Soc Prev Community Dent       Date:  2019-02-13
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.