[Principles of fixation of the cementless modular revision stem Revitan].

B Fink1, M Fuerst, M Hahn, L Thybaud, H-P Sieber, G Delling.   

Abstract

AIM AND
METHOD: To analyse the femoral fixation of a modular cementless revision endoprosthesis, eight prosthetic combinations of the Revitan-System (Centerpulse, Winterthur, Switzerland) were implanted in four cadavers. On three cadavers a curved revision Revitan stem was implanted by an endofemoral approach on one side and by a transfemoral approach on the contralateral side. On the fourth cadaver a straight Revitan stem was implanted on one side and a curved Revitan stem on the contralateral side using a transfemoral approach. Transversal slides of 7-8 mm thickness were performed at the fixation areas of each implant and the implant-bone contact was analysed macroscopically and using contact radiography.
RESULTS: The straight stem implanted by a transfemoral approach showed a double-conical press-fit fixation with cutting of the eight longitudinal fins into the cortical bone. The curved revision stems implanted by the same approach had a circular surface fixation similar to the press-fit fixation of the straight stem. In contrast, the curved stems implanted by the endofemoral approach (without a window) showed a three-surface fixation. Hereby the two distal fixation areas led to the primary implant stability by three of the four double edges of the octagonal cross-sectional area cutting into the cortical bone. At the proximal fixation zone the implant only had contact of two implant double edges to the cortical bone.
CONCLUSION: Different approaches for implantation lead to different fixation techniques of a curved revision stem. This should be considered by analysing postoperative sintering rates of cementless revision stems.

Mesh:

Year:  2005        PMID: 16133288     DOI: 10.1007/s00113-005-0990-4

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  11 in total

1.  Minimum 10-year-results of extensively porous-coated stems in revision hip arthroplasty.

Authors:  W G Paprosky; N V Greidanus; J Antoniou
Journal:  Clin Orthop Relat Res       Date:  1999-12       Impact factor: 4.176

2.  [The value of the Wagner SL revision prosthesis for bridging large femoral defects].

Authors:  H P Bircher; U Riede; M Lüem; P E Ochsner
Journal:  Orthopade       Date:  2001-05       Impact factor: 1.087

3.  Reduction in cement-bone interface shear strength between primary and revision arthroplasty.

Authors:  Y Dohmae; J E Bechtold; R E Sherman; R M Puno; R B Gustilo
Journal:  Clin Orthop Relat Res       Date:  1988-11       Impact factor: 4.176

4.  Porous-coated hip replacement. The factors governing bone ingrowth, stress shielding, and clinical results.

Authors:  C A Engh; J D Bobyn; A H Glassman
Journal:  J Bone Joint Surg Br       Date:  1987-01

5.  Development and first experience with an uncemented press-fit cup.

Authors:  E Morscher; Z Masar
Journal:  Clin Orthop Relat Res       Date:  1988-07       Impact factor: 4.176

6.  [A revision prosthesis for the hip joint].

Authors:  H Wagner
Journal:  Orthopade       Date:  1989-09       Impact factor: 1.087

7.  [Femur revision prosthesis].

Authors:  H Wagner; M Wagner
Journal:  Z Orthop Ihre Grenzgeb       Date:  1993 Nov-Dec

8.  Principles of acetabular fixation in THR with special reference to the "press-fit cup".

Authors:  E Morscher
Journal:  Acta Orthop Belg       Date:  1993       Impact factor: 0.500

Review 9.  [Etiology, diagnosis and therapy of aseptic hip prosthesis loosening--a status assessment].

Authors:  D C Wirtz; F U Niethard
Journal:  Z Orthop Ihre Grenzgeb       Date:  1997 Jul-Aug

10.  Assessment of press-fit hip femoral components retrieved at autopsy.

Authors:  D K Lester; P Campbell; A Ehya; R K Rude
Journal:  Orthopedics       Date:  1998-01       Impact factor: 1.390

View more
  10 in total

1.  [Replacement of femoral hip prostheses].

Authors:  M Rudert; M Hoberg; P M Prodinger; R Gradinger; B M Holzapfel
Journal:  Chirurg       Date:  2010-04       Impact factor: 0.955

2.  Revision arthroplasty in periprosthetic fractures of the proximal femur.

Authors:  B Fink
Journal:  Oper Orthop Traumatol       Date:  2014-09-28       Impact factor: 1.154

3.  Letter to the Editor: Is There a Benefit to Modularity in 'Simpler' Femoral Revisions?

Authors:  Bernd Fink
Journal:  Clin Orthop Relat Res       Date:  2016-07-21       Impact factor: 4.176

Review 4.  [Periprosthetic fractures after total hip arthroplasty : classification, diagnosis and therapy strategies].

Authors:  B M Holzapfel; P M Prodinger; M Hoberg; R Meffert; M Rudert; R Gradinger
Journal:  Orthopade       Date:  2010-05       Impact factor: 1.087

5.  Two-stage cementless revision of infected hip endoprostheses.

Authors:  Bernd Fink; Alexandra Grossmann; Martin Fuerst; Peter Schäfer; Lars Frommelt
Journal:  Clin Orthop Relat Res       Date:  2008-11-11       Impact factor: 4.176

6.  Hemiarthroplasty for neck of femur fractures: to cement or not? A systematic review of literature and meta-analysis.

Authors:  Prasoon Kumar; Rajesh Kumar Rajnish; Deepak Neradi; Vishal Kumar; Saurabh Agarwal; Sameer Aggarwal
Journal:  Eur J Orthop Surg Traumatol       Date:  2019-01-29

7.  Technical Note for Transfemoral Implantation of Tapered Revision Stems. The Advantage to Stay Short.

Authors:  Bernd Fink
Journal:  Arthroplast Today       Date:  2021-04-24

Review 8.  Revision of late periprosthetic infections of total hip endoprostheses: pros and cons of different concepts.

Authors:  Bernd Fink
Journal:  Int J Med Sci       Date:  2009-09-04       Impact factor: 3.738

9.  Common hip conditions requiring primary total hip arthroplasty and comparison of their post-operative functional outcomes.

Authors:  Prasoon Kumar; Ramesh K Sen; Sameer Aggarwal; Karan Jindal
Journal:  J Clin Orthop Trauma       Date:  2019-02-10

10.  What can the surgeon do to reduce the risk of junction breakage in modular revision stems?

Authors:  Bernd Fink
Journal:  Arthroplast Today       Date:  2018-08-31
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.