Literature DB >> 8500934

[Acetabulum without cement. Short-term results of a series of 112 threaded cups].

F Gouin1, F Fechoz, N Passuti, J Sentucq-Rigal, O Bertrand, J V Bainvel.   

Abstract

Between January 1982 and December 1987 we used 112 threaded acetabular cups in 102 patients undergoing total hip replacement. The clinical and radiographic results of 107 implants are reported in this survey. Using the functional grading of the hip advocated by Merle d'Aubigné and Postel, 62% can be classified as excellent, very good or good. On x-ray only 35% of the cups show neither radiolucency at the bone-implant interface nor migration of the component. There is a statistically significant correlation between a radiolucency in 2 of the 3 areas at the bone-implant interface and the clinical result. The revision rate for failure of the cup is 11.6% (13 implants). The actuarial survival of the threaded cup decreased from 0.95 in the 1st year to 0.75 in the 5th year after implantation. Analysis of our failures and of published data suggest that the problem lies in the lack of primary bone integration. We describe our difficulties in assessing risk factors, in interpreting the radiographs and in the intraoperative determination of component instability. The disappointing short term results have prompted us to abandon the use of threaded cups.

Entities:  

Mesh:

Year:  1993        PMID: 8500934     DOI: 10.1007/BF00183544

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  27 in total

1.  [Total hip prosthesis with screw rings. Results over 2 years of a series of 198 consecutive prostheses].

Authors:  J Duparc; P Massin
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1991

Review 2.  [Study of loosening and wear of total hip prosthesis. Apropos of a series followed-up over 10 years].

Authors:  P Delagoutte; D Mainard; M Dupuy; G Peltre; C G'Sell
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1991

3.  Cementless acetabular components.

Authors:  C A Engh; W L Griffin; C L Marx
Journal:  J Bone Joint Surg Br       Date:  1990-01

4.  [Numerical classification of the function of the hip. 1970].

Authors:  R Merle D'Aubigné
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1990

5.  [Madreporic, polarized total arthroplasties of the hip. Apropos of 2688 cases].

Authors:  G Lord; J H Marotte; J P Blanchard; J L Guillamon; J Servant; P Samuel; R Gentaz
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1988

6.  The long-term results of low-friction arthroplasty of the hip performed as a primary intervention.

Authors:  J Charnley
Journal:  J Bone Joint Surg Br       Date:  1972-02

7.  Migration of the acetabular socket after total hip replacement determined by roentgen stereophotogrammetry.

Authors:  H Baldursson; L I Hansson; T H Olsson; G Selvik
Journal:  Acta Orthop Scand       Date:  1980-06

8.  15-21-year results of the Charnley low-friction arthroplasty.

Authors:  B M Wroblewski
Journal:  Clin Orthop Relat Res       Date:  1986-10       Impact factor: 4.176

9.  Survivorship comparison of THARIES and conventional hip arthroplasty in patients younger than 40 years old.

Authors:  W C Kim; T Grogan; H C Amstutz; F Dorey
Journal:  Clin Orthop Relat Res       Date:  1987-01       Impact factor: 4.176

Review 10.  [Spontaneous bilateral rupture of the extensor system of the knee in a patient with renal transplantation. Apropos of a case].

Authors:  K Lauridsen; B F Nielsen; T Lind
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  1989
View more