Literature DB >> 33807917

Swept Source Optical Coherence Tomography Analysis of the Selected Eye's Anterior Segment Parameters.

Michał Dembski1,2, Anna Nowińska2, Klaudia Ulfik-Dembska1,2, Edward Wylęgała1,2.   

Abstract

BACKGROUND: The present study determined the mean reference values of the anterior segment parameters of the selected eye using swept source optical coherence tomography (SS-OCT) in healthy Caucasian participants.
METHODS: A total of 166 volunteers (age 54-79 years), women (n = 92) and men (n = 74), were analyzed. One eye of each subject was randomly selected for anterior segment imaging. The anterior segment of the eye was scanned with CASIA2. The analyzed anterior segment parameters were divided into three groups, namely parameters of the cornea, lens, and angle.
RESULTS: The OCT (e.g., Ks, Kf, pKf, pKs, and central corneal thickness) and Fourier parameters of the cornea were significantly different between females and males. The iridocorneal angle was the smallest in the upper quadrant for all distance from the apex of the angle (250, 500, and 750 µm).
CONCLUSIONS: Therefore, SS-OCT enables the analysis of parameters of the cornea, anterior chamber, lens, and iridocorneal angle, highlighting its clinical utility. Sex-specific differences in the analyzed parameters should be taken into account during the diagnosis of corneal diseases. The configuration of the filtration angle is an important marker during glaucoma diagnosis and drainage implant surgery. Measurements with CASIA 2is characterized by very good repeatability.

Entities:  

Keywords:  anterior chamber angle; cornea; keratometry; optical coherence tomography

Year:  2021        PMID: 33807917      PMCID: PMC7961440          DOI: 10.3390/jcm10051094

Source DB:  PubMed          Journal:  J Clin Med        ISSN: 2077-0383            Impact factor:   4.241


  37 in total

1.  Real-time optical coherence tomography of the anterior segment at 1310 nm.

Authors:  S Radhakrishnan; A M Rollins; J E Roth; S Yazdanfar; V Westphal; D S Bardenstein; J A Izatt
Journal:  Arch Ophthalmol       Date:  2001-08

2.  Reliability and repeatability of swept-source Fourier-domain optical coherence tomography and Scheimpflug imaging in keratoconus.

Authors:  Eszter Szalai; András Berta; Ziad Hassan; László Módis
Journal:  J Cataract Refract Surg       Date:  2012-01-20       Impact factor: 3.351

3.  Assessment of Lens Center Using Optical Coherence Tomography, Magnetic Resonance Imaging, and Photographs of the Anterior Segment of the Eye.

Authors:  Yong Eun Lee; Choun-Ki Joo
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-08       Impact factor: 4.799

4.  Three-dimensional and high-speed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments.

Authors:  Yoshiaki Yasuno; Violeta Dimitrova Madjarova; Shuichi Makita; Masahiro Akiba; Atsushi Morosawa; Changho Chong; Toru Sakai; Kin-Pui Chan; Masahide Itoh; Toyohiko Yatagai
Journal:  Opt Express       Date:  2005-12-26       Impact factor: 3.894

5.  Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography.

Authors:  Edward Wylegała; Slawomir Teper; Anna K Nowińska; Michal Milka; Dariusz Dobrowolski
Journal:  J Cataract Refract Surg       Date:  2009-08       Impact factor: 3.351

6.  Noncontact Screening Methods for the Detection of Narrow Anterior Chamber Angles.

Authors:  Priya L Dabasia; David F Edgar; Ian E Murdoch; John G Lawrenson
Journal:  Invest Ophthalmol Vis Sci       Date:  2015-06       Impact factor: 4.799

Review 7.  Anterior segment optical coherence tomography and its clinical applications.

Authors:  Sarah B Wang; Elisa E Cornish; John R Grigg; Peter J McCluskey
Journal:  Clin Exp Optom       Date:  2019-01-12       Impact factor: 2.742

8.  Corneal power measurement with Fourier-domain optical coherence tomography.

Authors:  Maolong Tang; Alex Chen; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2010-12       Impact factor: 3.351

9.  Comparison of Scheimpflug imaging and spectral domain anterior segment optical coherence tomography for detection of narrow anterior chamber angles.

Authors:  D S Grewal; G S Brar; R Jain; S P S Grewal
Journal:  Eye (Lond)       Date:  2011-02-18       Impact factor: 3.775

View more
  2 in total

Review 1.  Imaging of iris vasculature: current limitations and future perspective.

Authors:  Claudio Iovino; Enrico Peiretti; Mirco Braghiroli; Filippo Tatti; Abhilasha Aloney; Michele Lanza; Jay Chhablani
Journal:  Eye (Lond)       Date:  2021-10-14       Impact factor: 4.456

2.  Swept Source Optical Coherence Tomography Analysis of a Selected Eye's Anterior Segment Parameters in Patients with Pseudoexfoliation Syndrome.

Authors:  Michał Dembski; Anna Nowińska; Klaudia Ulfik-Dembska; Edward Wylęgała
Journal:  J Clin Med       Date:  2022-01-05       Impact factor: 4.241

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.