Literature DB >> 30635934

Anterior segment optical coherence tomography and its clinical applications.

Sarah B Wang1, Elisa E Cornish1,2,3, John R Grigg1, Peter J McCluskey1.   

Abstract

Anterior segment optical coherence tomography (AS-OCT) has become one of the cornerstones of non-contact imaging modalities for assessing such structures as the cornea, anterior chamber angle, aqueous outflow pathway, sclera, and ocular surface structures. As such, it has a broad range of clinical applications, which have been independently reported in the literature. This paper aims to present a review of extant literature on the utility of AS-OCT and its efficacy in clinical applications, and to evaluate the quality of available evidence. The following databases were searched from inception to 24 June 2018: Medline via Ovid, Cochrane Central Register of Controlled Trials, PubMed, World Health Organization International Clinical Trials Registry Platform, EMBASE, and CINAHL. Bibliographies of identified papers were hand searched. Inclusion criteria: articles describing or assessing the use of OCT for visualising the AS. The authors excluded studies without an identified primary outcome variable. One author independently selected studies, extracted data, and assessed for risk of bias using PRISMA guidelines. This review included 82 studies, of which there were 11 cohort studies, 37 case series, 10 case studies, 21 comparative observational studies, and three non-systematic review articles. Primary outcome variables included anterior chamber angle, angle opening distance, angle recess area, trabecular iris angle, trabecula-iris space area, corneal thickness, tear meniscus height, tear meniscus area, tear meniscus volume, and the morphology of AS structures, including the ocular surface, blebs, flaps, and graft sites. This review attempts to encompass the breadth and depth of evidence for AS-OCT in the arena of diagnostics, therapeutics, and prognostics. At the same time, it brings to light the dearth of high-level evidence on this topic, suggesting the important role of randomised controlled trials and meta-analyses for the future validation of this technology.
© 2019 Optometry Australia.

Entities:  

Keywords:  angle; anterior segment; cornea; glaucoma; optical coherence tomography; sclera

Mesh:

Year:  2019        PMID: 30635934     DOI: 10.1111/cxo.12869

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  11 in total

1.  Anterior Segment Optical Coherence Tomography: Applications for Clinical Care and Scientific Research.

Authors:  Jing Shan; Charles DeBoer; Benjamin Y Xu
Journal:  Asia Pac J Ophthalmol (Phila)       Date:  2019-04-25

2.  The clinical features and the factors affecting visual prognosis in pediatric open-globe ınjuries.

Authors:  Hakan Öztürk; Bediz Özen
Journal:  Int Ophthalmol       Date:  2022-05-17       Impact factor: 2.029

3.  Clinical Observation of Corneal Endothelial Plaques With Fungal and Bacterial Keratitis by Anterior Segment Optical Coherence Tomography and In Vivo Confocal Microscopy.

Authors:  Xin Jin; Hao Jin; Yan Shi; Nan Zhang; Hong Zhang
Journal:  Cornea       Date:  2021-11-10       Impact factor: 3.152

Review 4.  The Value of Anterior Segment Optical Coherence Tomography in Different Types of Corneal Infections: An Update.

Authors:  Ahmed A Abdelghany; Francesco D'Oria; Jorge Alio Del Barrio; Jorge L Alio
Journal:  J Clin Med       Date:  2021-06-27       Impact factor: 4.241

5.  Comparison of Femtosecond Laser-Assisted and Ultrasound-Assisted Cataract Surgery with Focus on Endothelial Analysis.

Authors:  Anna Schroeter; Martina Kropp; Zeljka Cvejic; Gabriele Thumann; Bojan Pajic
Journal:  Sensors (Basel)       Date:  2021-02-02       Impact factor: 3.576

6.  Swept Source Optical Coherence Tomography Analysis of a Selected Eye's Anterior Segment Parameters in Patients with Pseudoexfoliation Syndrome.

Authors:  Michał Dembski; Anna Nowińska; Klaudia Ulfik-Dembska; Edward Wylęgała
Journal:  J Clin Med       Date:  2022-01-05       Impact factor: 4.241

Review 7.  Towards a Connected Mobile Cataract Screening System: A Future Approach.

Authors:  Wan Mimi Diyana Wan Zaki; Haliza Abdul Mutalib; Laily Azyan Ramlan; Aini Hussain; Aouache Mustapha
Journal:  J Imaging       Date:  2022-02-10

8.  Correlation Between Degree of Lens Opacity and the Phacoemulsification Energy Parameters Using Different Imaging Methods in Age-Related Cataract.

Authors:  Li Feng; Fangkun Zhao; Xin Ke; Jiangyue Zhao; Mingyu Shi
Journal:  Transl Vis Sci Technol       Date:  2022-03-02       Impact factor: 3.283

9.  Corneal pachymetry by AS-OCT after Descemet's membrane endothelial keratoplasty.

Authors:  Friso G Heslinga; Ruben T Lucassen; Myrthe A van den Berg; Luuk van der Hoek; Josien P W Pluim; Javier Cabrerizo; Mark Alberti; Mitko Veta
Journal:  Sci Rep       Date:  2021-07-07       Impact factor: 4.379

10.  Swept Source Optical Coherence Tomography Analysis of the Selected Eye's Anterior Segment Parameters.

Authors:  Michał Dembski; Anna Nowińska; Klaudia Ulfik-Dembska; Edward Wylęgała
Journal:  J Clin Med       Date:  2021-03-05       Impact factor: 4.241

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.