Literature DB >> 19631129

Anterior segment imaging: Fourier-domain optical coherence tomography versus time-domain optical coherence tomography.

Edward Wylegała1, Slawomir Teper, Anna K Nowińska, Michal Milka, Dariusz Dobrowolski.   

Abstract

PURPOSE: To compare anterior segment measurements and morphology of 2 optical coherence tomography (OCT) systems.
SETTING: Department of Ophthalmology, District Railway Hospital, and the Nursing Department and Social Medical Issues, Health Care Division, Silesian Medical University, Katowice, Poland.
METHODS: In normal eyes and in eyes with corneal and trabecular-iris angle disorders, the central corneal thickness (CCT), trabecular-iris angle, and angle-opening distance at the nasal and temporal angles were measured 3 times during 1 visit using the Visante time-domain OCT system and the RTVue-100 Fourier-domain corneal anterior module OCT system. Anterior segment morphology was assessed and compared.
RESULTS: Fifty-four eyes were evaluated. The mean values (+/-SD) by time-domain OCT and Fourier-domain OCT were, respectively, automatic CCT, 535 +/- 33.07 microm and 538 +/- 31.82 microm; manual CCT, 545 +/- 30.91 microm and 542 +/- 30.57 microm; nasal trabecular-iris angle, 34.7 +/- 9.5 degrees and 35.2 +/- 8.9 degrees; temporal trabecular-iris angle, 35.3 +/- 8.5 degrees and 35.5 +/- 9 degrees; nasal angle-opening distance, 435 +/- 95 microm and 444 +/- 98 microm; and temporal angle-opening distance, 443 +/- 103 microm and 452 +/- 99 microm. There was no significant difference between mean values, and they were highly correlated. On morphologic analysis, time-domain OCT had lower resolution; however, all anterior chamber structures were visible on 1 image. Fourier-domain OCT provided precise information about small areas of the anterior chamber.
CONCLUSION: Fourier-domain OCT provided accurate anterior eye segment measurements that agreed with those obtained with time-domain OCT.

Entities:  

Mesh:

Year:  2009        PMID: 19631129     DOI: 10.1016/j.jcrs.2009.03.034

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  26 in total

1.  Anterior chamber angle imaging with optical coherence tomography.

Authors:  C K-S Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-14       Impact factor: 3.775

2.  Optical coherence tomography characteristics of different types of big bubbles seen in deep anterior lamellar keratoplasty by the big bubble technique.

Authors:  S L AlTaan; K Termote; M S Elalfy; E Hogan; R Werkmeister; L Schmetterer; S Holland; H S Dua
Journal:  Eye (Lond)       Date:  2016-07-29       Impact factor: 3.775

3.  Geometrical characterization of the corneo-scleral transition in normal patients with Fourier domain optical coherence tomography.

Authors:  Mar Seguí-Crespo; Miguel Ángel Ariza-Gracia; Nelva de Luisa David Sixpene; David P Piñero
Journal:  Int Ophthalmol       Date:  2019-05-07       Impact factor: 2.031

4.  Assessment of the Retinal Vessels in Keratoconus: An OCT Angiography Study.

Authors:  Adam Wylęgała; Dominika Szkodny; Rafał Fiolka; Edward Wylęgała
Journal:  J Clin Med       Date:  2022-05-24       Impact factor: 4.964

5.  Swept source optical coherence tomography measurement of the iris-trabecular contact (ITC) index: a new parameter for angle closure.

Authors:  Sue-Wei Ho; Mani Baskaran; Ce Zheng; Tin A Tun; Shamira A Perera; Arun K Narayanaswamy; David S Friedman; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-23       Impact factor: 3.117

6.  Role of optical coherence tomography on corneal surface laser ablation.

Authors:  Bruna V Ventura; Haroldo V Moraes; Newton Kara-Junior; Marcony R Santhiago
Journal:  J Ophthalmol       Date:  2012-09-05       Impact factor: 1.909

Review 7.  Angle imaging: advances and challenges.

Authors:  Desmond T L Quek; Monisha E Nongpiur; Shamira A Perera; Tin Aung
Journal:  Indian J Ophthalmol       Date:  2011-01       Impact factor: 1.848

8.  Anterior chamber angle evaluation with fourier-domain optical coherence tomography.

Authors:  Matthew Bald; Yan Li; David Huang
Journal:  J Ophthalmol       Date:  2012-07-02       Impact factor: 1.909

9.  Reproducibility of Corneal Graft Thickness measurements with COLGATE in patients who have undergone DSAEK (Descemet Stripping Automated Endothelial Keratoplasty).

Authors:  Melissa H Y Wong; Annabel Chew; Hla M Htoon; Beng H Lee; Jun Cheng; Jiang Liu; Donald T Tan; Jodhbir S Mehta
Journal:  BMC Med Imaging       Date:  2012-08-01       Impact factor: 1.930

10.  Reproducibility and age-related changes of ocular parametric measurements in rabbits.

Authors:  Andri K Riau; Neil Y S Tan; Romesh I Angunawela; Hla M Htoon; Shyam S Chaurasia; Jodhbir S Mehta
Journal:  BMC Vet Res       Date:  2012-08-19       Impact factor: 2.741

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.