Literature DB >> 11483086

Real-time optical coherence tomography of the anterior segment at 1310 nm.

S Radhakrishnan1, A M Rollins, J E Roth, S Yazdanfar, V Westphal, D S Bardenstein, J A Izatt.   

Abstract

BACKGROUND: Recent advances in high-speed scanning technology have enabled a new generation of optical coherence tomographic (OCT) systems to perform imaging at video rate. Here, a handheld OCT probe capable of imaging the anterior segment of the eye at high frame rates is demonstrated for the first time.
OBJECTIVE: To demonstrate real-time OCT imaging of anterior segment structures.
DESIGN: Survey of anterior segment structures in normal human subjects.
SETTING: Laboratory. MAIN OUTCOME MEASURES: Achieving real-time imaging of the anterior segment, satisfactory image quality, and convenience of a handheld probe.
RESULTS: Optical coherence tomographic imaging of the anterior segment of the eyes of human subjects was performed using 1310-nm wavelength light with an image rate of 8 frames per second. Imaging trials demonstrated clear resolution of corneal epithelium and stroma, sclerocorneal junction, sclera, iris pigment epithelium and stroma, and anterior lens capsule. The anterior chamber angle was clearly visualized. Limited imaging of the ciliary body was performed. Real-time imaging of pupillary constriction in response to light stimulus was also performed.
CONCLUSION: High-speed OCT at 1310-nm wavelength is a potentially useful technique for noninvasive assessment of anterior segment structures. CLINICAL RELEVANCE: Our results suggest that real-time OCT has potential applications in glaucoma evaluation and refractive surgery.

Entities:  

Mesh:

Year:  2001        PMID: 11483086     DOI: 10.1001/archopht.119.8.1179

Source DB:  PubMed          Journal:  Arch Ophthalmol        ISSN: 0003-9950


  120 in total

1.  [Reproducibility of goniometry with slitlamp-adapted optical coherence tomography].

Authors:  A Karandish; C Wirbelauer; H Häberle; D T Pham
Journal:  Ophthalmologe       Date:  2004-06       Impact factor: 1.059

2.  Comparison of the anterior ocular segment measurements using swept-source optical coherent tomography and a scanning peripheral anterior chamber depth analyzer.

Authors:  Toshie Furuya; Fumihiko Mabuchi; Tatsuya Chiba; Satoshi Kogure; Shigeo Tsukahara; Kenji Kashiwagi
Journal:  Jpn J Ophthalmol       Date:  2011-08-10       Impact factor: 2.447

3.  Handheld, rapidly switchable, anterior/posterior segment swept source optical coherence tomography probe.

Authors:  Derek Nankivil; Gar Waterman; Francesco LaRocca; Brenton Keller; Anthony N Kuo; Joseph A Izatt
Journal:  Biomed Opt Express       Date:  2015-10-21       Impact factor: 3.732

4.  Primary Acquired Melanosis: Clinical, Histopathologic and Optical Coherence Tomographic Correlation.

Authors:  Yahya A Alzahrani; Smita Kumar; Hassan Abdul Aziz; Thomas Plesec; Arun D Singh
Journal:  Ocul Oncol Pathol       Date:  2015-11-12

Review 5.  Molecular contrast optical coherence tomography: a review.

Authors:  Changhuei Yang
Journal:  Photochem Photobiol       Date:  2005 Mar-Apr       Impact factor: 3.421

6.  Anterior chamber width measurement by high-speed optical coherence tomography.

Authors:  Jason A Goldsmith; Yan Li; Maria Regina Chalita; Volker Westphal; Chetan A Patil; Andrew M Rollins; Joseph A Izatt; David Huang
Journal:  Ophthalmology       Date:  2005-02       Impact factor: 12.079

7.  Corneal pachymetry mapping with high-speed optical coherence tomography.

Authors:  Yan Li; Raj Shekhar; David Huang
Journal:  Ophthalmology       Date:  2006-05       Impact factor: 12.079

Review 8.  Ultra high-resolution anterior segment optical coherence tomography in the diagnosis and management of ocular surface squamous neoplasia.

Authors:  Benjamin J Thomas; Anat Galor; Afshan A Nanji; Fouad El Sayyad; Jianhua Wang; Sander R Dubovy; Madhura G Joag; Carol L Karp
Journal:  Ocul Surf       Date:  2013-11-09       Impact factor: 5.033

9.  Optical effects of anti-TGFbeta treatment after photorefractive keratectomy in a cat model.

Authors:  Jens Bühren; Lana Nagy; Jennifer N Swanton; Shawn Kenner; Scott MacRae; Richard P Phipps; Krystel R Huxlin
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-10-24       Impact factor: 4.799

10.  Reproducibility of tear meniscus measurement by Fourier-domain optical coherence tomography: a pilot study.

Authors:  Sheng Zhou; Yan Li; Ake Tzu-Hui Lu; Pengfei Liu; Maolong Tang; Samuel C Yiu; David Huang
Journal:  Ophthalmic Surg Lasers Imaging       Date:  2009 Sep-Oct
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.