Literature DB >> 22261325

Reliability and repeatability of swept-source Fourier-domain optical coherence tomography and Scheimpflug imaging in keratoconus.

Eszter Szalai1, András Berta, Ziad Hassan, László Módis.   

Abstract

PURPOSE: To evaluate the repeatability and reliability of a recently introduced swept-source Fourier-domain anterior segment optical coherence tomography (AS-OCT) system and a high-resolution Scheimpflug camera and to assess the agreement between the 2 instruments when measuring healthy eyes and eyes with keratoconus.
SETTING: Department of Ophthalmology, Medical and Health Science Center, University of Debrecen, Debrecen, Hungary.
DESIGN: Evaluation of diagnostic test or technology.
METHODS: Three consecutive series of anterior segment images were taken with AS-OCT (Casia SS-1000) followed by rotating Scheimpflug imaging (Pentacam high resolution). Axial keratometry in the steep and flat meridians and astigmatism values were recorded. Pachymetry in the apex, center, and the thinnest position and anterior chamber depth (ACD) measurements were also taken.
RESULTS: This study enrolled 57 healthy volunteers (57 eyes) and 56 patients (84 eyes) with keratoconus. Significant difference was found in all measured anterior segment parameters between normal eyes and keratoconic eyes (P<.05). In keratoconic eyes, the difference between repeated measurements was less with AS-OCT than with Scheimpflug imaging in every keratometry and astigmatism value, in apical thickness, and in ACD. For keratometry, the thinnest and central pachymetry measurement repeatability was better in healthy eyes than in keratoconic eyes with both instruments. In general, the mean difference between AS-OCT and Scheimpflug imaging was higher in cases of keratoconus.
CONCLUSIONS: Significant differences in keratometry, pachymetry, and ACD results were found between AS-OCT and Scheimpflug imaging. However, the repeatability of the measurements was comparable. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Copyright © 2012 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22261325     DOI: 10.1016/j.jcrs.2011.10.027

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  33 in total

Review 1.  New clinical pathways for keratoconus.

Authors:  D M Gore; A J Shortt; B D Allan
Journal:  Eye (Lond)       Date:  2012-12-21       Impact factor: 3.775

Review 2.  [Corneal topography and keratoconus diagnostics with Scheimpflug photography].

Authors:  J Bühren
Journal:  Ophthalmologe       Date:  2014-10       Impact factor: 1.059

3.  Comparison of Scheimpflug and swept-source anterior segment optical coherence tomography in normal and keratoconus eyes.

Authors:  Seyed Mohammad Ghoreishi; Seyed Ali Akbar Mortazavi; Zahra-Alsadat Abtahi; Mohammad-Ali Abtahi; Seyed Ali Sonbolestan; Seyed-Hossein Abtahi; Mohadeseh Mohammadinia; Kimia Nekouie Isfahani
Journal:  Int Ophthalmol       Date:  2016-09-26       Impact factor: 2.031

4.  The change of anterior segment parameters after cataract surgery in normal-tension glaucoma.

Authors:  Wonseok Lee; Hyoung Won Bae; Chan Yun Kim; Gong Je Seong
Journal:  Int J Ophthalmol       Date:  2017-08-18       Impact factor: 1.779

5.  Keratoconus diagnosis with optical coherence tomography–based pachymetric scoring system.

Authors:  Bing Qin; Shihao Chen; Robert Brass; Yan Li; Maolong Tang; Xinbo Zhang; Xiaoyu Wang; Qinmei Wang; David Huang
Journal:  J Cataract Refract Surg       Date:  2013-12       Impact factor: 3.351

6.  Prospective, randomized, double-blind trial to investigate the efficacy and safety of corneal cross-linking to halt the progression of keratoconus.

Authors:  Stefan J Lang; Elisabeth M Messmer; Gerd Geerling; Marc J Mackert; Tobias Brunner; Sylvia Dollak; Borislav Kutchoukov; Daniel Böhringer; Thomas Reinhard; Philip Maier
Journal:  BMC Ophthalmol       Date:  2015-07-21       Impact factor: 2.209

7.  Influence of posterior corneal astigmatism on postoperative refractive astigmatism in pseudophakic eyes after cataract surgery.

Authors:  Maki Sano; Takahiro Hiraoka; Yuta Ueno; Hideo Itagaki; Tomohiro Ogami; Tetsuro Oshika
Journal:  BMC Ophthalmol       Date:  2016-12-01       Impact factor: 2.209

8.  Accuracy of OCT-derived net corneal astigmatism measurement.

Authors:  Clara Llorens-Quintana; Elias Pavlatos; Omkar Thaware; Seema Gupta; Daniel Gradin; Denzil Romfh; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2022-03-01       Impact factor: 3.528

9.  Comparative Study of Anterior Eye Segment Measurements with Spectral Swept-Source and Time-Domain Optical Coherence Tomography in Eyes with Corneal Dystrophies.

Authors:  Anna K Nowinska; Sławomir J Teper; Dominika A Janiszewska; Anita Lyssek-Boron; Dariusz Dobrowolski; Robert Koprowski; Edward Wylegala
Journal:  Biomed Res Int       Date:  2015-09-17       Impact factor: 3.411

10.  Comparability and repeatability of pachymetry in keratoconus using four noncontact techniques.

Authors:  Mukesh Kumar; Rohit Shetty; Chaitra Jayadev; Debarun Dutta
Journal:  Indian J Ophthalmol       Date:  2015-09       Impact factor: 1.848

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.