| Literature DB >> 33229691 |
Sonam Yangzes1, Neha Kamble1, Sartaj Grewal1, Satinder P S Grewal1.
Abstract
PURPOSE: The aim of this study was to compare the visual outcomes of two monofocal intraocular lenses (IOLs), with emphasis on the defocus curve.Entities:
Keywords: Defocus curve; Tecnis Eyhance; extended depth of focus; intermediate vision; monofocal IOL
Mesh:
Year: 2020 PMID: 33229691 PMCID: PMC7856977 DOI: 10.4103/ijo.IJO_985_20
Source DB: PubMed Journal: Indian J Ophthalmol ISSN: 0301-4738 Impact factor: 1.848
Pre-operative parameters and patient demographic in each group
| Parameter | Eyhance (ICB00) group | Tecnis I (ZCB00) group | |||||
|---|---|---|---|---|---|---|---|
| No. of eyes Gender distribution | 71 | 45 | |||||
| Age (years) | 65.43 | 6.76 | 51-79 | 62.64 | 14.25 | 29-85 | 0.08* |
| AL (mm) | 23.59 | 1.08 | 21.47-26.38 | 23.79 | 1.35 | 22-28.59 | 0.19* |
| ACD (mm) | 3.24 | 0.44 | 2.25-4.27 | 3.20 | 0.43 | 1.93-4.1 | 0.32* |
| Flattest keratometry | 43.61 | 1.65 | 40.53-48 | 43.17 | 1.20 | 40.3-46 | 0.06* |
| Steepest keratometry | 44.31 | 1.75 | 41.16-50.46 | 44.18 | 1.34 | 41.6-47.65 | 0.33* |
| Keratometry average | 43.98 | 1.69 | 40.99-49.20 | 43.67 | 1.22 | 40.97-46.37 | 0.15* |
| LogMAR Uncorrected distance VA | 1.06 | 0.67 | 0.10-2.00 | 1.01 | 0.69 | 0.10-2.00 | 0.43† |
| LogMAR Corrected Distance VA | 0.55 | 0.55 | 0.00-2.00 | 0.41 | 0.46 | 0.00-2.00 | 0.15† |
| Sphere (D) | -1.01 | 3.04 | -16.00-2.50 | -0.88 | 3.08 | -14.00-3.25 | 0.63† |
| Cylinder (D) | -0.17 | 0.83 | -3.25-1.75 | -0.18 | 0.97 | -2.50-2.00 | 0.93† |
| Spherical Equivalent (D) | -1.10 | 3.29 | -17.5-3.00 | -0.97 | 3.26 | -14.5-3.50 | 0.72† |
| LogMAR Corrected Near VA | 0.57 | 0.30 | 0.30-1.20 | 0.50 | 0.28 | 0.30-1.20 | 0.31† |
ACD=Anterior chamber depth; AL=Axial length; VA=Visual acuity. *Unpaired student t-test, †Mann-Whitney test
Post-operative visual acuity in each group
| Parameter | 2 week post-operative | ||
|---|---|---|---|
| Eyhance (ICB00) group | Tecnis I (ZCB00) group | ||
| LogMAR Uncorrected Distance VA | |||
| Mean (SD) | 0.10 (0.13) | 0.09 (0.11) | 0.84 |
| Range | 0.00-0.60 | 0.00-0.48 | |
| LogMAR Corrected Distance VA | |||
| Mean (SD) | 0.02 (0.05) | 0.01 (0.04) | 0.638 |
| Range | 0.00-0.30 | 0.00-0.30 | |
| Sphere (D) | |||
| Mean (SD) | -0.03 (0.26) | -0.005 (0.19) | 0.49 |
| Range | -0.75-1.00 | -0.75-0.75 | |
| Cylinder (D) | |||
| Mean (SD) | -0.08 (0.39) | -0.10 (0.37) | 0.64 |
| Range | -1.00-1.00 | -0.75-0.75 | |
| Spherical Equivalent (D) | |||
| Mean (SD) | -0.017 (0.33) | 0.005 (0.24) | 0.56 |
| Range | -0.75-1.25 | -1.00-0.50 | |
| LogMAR Uncorrected Intermediate VA | |||
| Mean (SD) | 0.11 (0.13) | 0.25 (0.18) | <0.01 |
| Range | 0.00-0.50 | 0.00-0.50 | |
| LogMAR Corrected Intermediate VA | |||
| Mean (SD) | 0.015 (0.057) | 0.006 (0.03) | 0.631 |
| Range | 0.00 to 0.40 | 0.00 to 0.20 | |
| LogMAR Uncorrected Near VA | |||
| Mean (SD) | 0.43 (0.13) | 0.61 (0.16) | <0.01 |
| Range | 0.00 to 0.80 | 0.40 to 1.00 | |
| LogMAR Corrected Near VA | |||
| Mean (SD) | 0.02 (0.07) | 0.08 (0.13) | 0.06 |
| Range | 0.00 to 0.50 | 0.00 to 0.30 | |
SD - Standard deviation, VA - Visual acuity. †Mann-Whitney test
Figure 1Comparative graph showing post-operative visual acuity at various distances in both groups. (VA- visual acuity, CNVA- corrected near visual acuity, UNVA- uncorrected near visual acuity, CIVA- corrected intermediate visual acuity, UIVA- uncorrected intermediate visual acuity, CDVA- corrected distance visual acuity, UDVA- uncorrected distance visual acuity)
Figure 2Defocus curve of Tecnis 1 and Eyhance IOL across defocus levels (+1 D to -4 D). †Mann-Whitney Test
Figure 3Scatter graph showing attempted distant visual acuity and achieved visual acuity in both groups