Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling.

Begoña Oteiza-Galdón1, Amparo Martínez-González1, Ángel-Vicente Escuder2.   

Abstract

BACKGROUND: This study analyzed the degree of passive and vertical fit achieved in frameworks using either cobalt-chromium (Co-Cr) or titanium (Ti) implant-supported fixed partial dentures ( FPDs) fabricated with a CAD/CAM milling technique.
MATERIAL AND METHODS: 33 3-unit FDPs, 17 of Co-Cr metal alloy (test group) and 16 of Ti (control group), were manufactured with two implants by copy milled technology. Optical microscopy was used to measure passive fit (PF) and vertical fit (VF) in all frameworks. The PF was evaluated by using the Single Screw test and the VF with the screws tightened at 20 Ncm. Descriptive and inferential analysis were performed to evaluate statistically significant differences in the tested groups for each fit. Brunner-Langer models were applied to assess potential material and implant area effects on the measurements. An ANOVA test was performed to estimate both main effects and interactions.
RESULTS: The average PF values in the screwed implant were 4.43 ± 0.52 µm for Ti and 5.50 ± 1.61 µm for Co-Cr and in the non-screwed implant 5.59 ± 1.32 µm in the group Ti and 6.25 ± 1.55 µm the Co-Cr group. In this last implant, it was not observed statistically significant differences between both types of alloy (p = 0.178) nor between zones. Ti control group exhibited a significantly better VF than Co-Cr (p = 0.046) in the screwed implant but there were no differences in the implant not screwed. The VF in the non-screwed implant was better in lingual than in buccal zone.
CONCLUSIONS: The PF and VF measurements observed in Co-Cr frameworks are clinically acceptable. 3-unit implant supported FPDs made with Co-Cr alloy using milling technique showed similar dimensional accuracy than those obtained with Ti. Key words:Cobalt- chromium alloy, misfit, passive fit, vertical fit, milling. Copyright:
© 2020 Medicina Oral S.L.

Entities:  

Year:  2020        PMID: 33154797      PMCID: PMC7600204          DOI: 10.4317/jced.57817

Source DB:  PubMed          Journal:  J Clin Exp Dent        ISSN: 1989-5488


  26 in total

Review 1.  The significance of passive framework fit in implant prosthodontics: current status.

Authors:  S Sahin; M C Cehreli
Journal:  Implant Dent       Date:  2001       Impact factor: 2.454

2.  Effect of vertical misfit on strain within screw-retained implant titanium and zirconia frameworks.

Authors:  Jaafar Abduo; Karl Lyons
Journal:  J Prosthodont Res       Date:  2011-11-16       Impact factor: 4.642

3.  Correlation between vertical misfits and stresses transmitted to implants from metal frameworks.

Authors:  Erica Miranda de Torres; Gustavo Augusto Seabra Barbosa; Sérgio Rocha Bernardes; Maria da Glória Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  J Biomech       Date:  2011-04-15       Impact factor: 2.712

4.  Use of base metal casting alloys for implant framework: marginal accuracy analysis.

Authors:  Stefania Carvalho Kano; Gerson Bonfante; Raquel Hussne; Aline F Siqueira
Journal:  J Appl Oral Sci       Date:  2004-12       Impact factor: 2.698

5.  Stress distribution after installation of fixed frameworks with marginal gaps over angled and parallel implants: a photoelastic analysis.

Authors:  Roberto Adrian Markarian; Cristiane Ueda; Claudio Luiz Sendyk; Dalva Cruz Laganá; Roberto Martins Souza
Journal:  J Prosthodont       Date:  2007 Mar-Apr       Impact factor: 2.752

6.  Influence of CAD/CAM on the fit accuracy of implant-supported zirconia and cobalt-chromium fixed dental prostheses.

Authors:  Danilo Gonzaga B de França; Maria Helena S T Morais; Flávio D das Neves; Gustavo A S Barbosa
Journal:  J Prosthet Dent       Date:  2014-09-30       Impact factor: 3.426

7.  Marginal fit and photoelastic stress analysis of CAD-CAM and overcast 3-unit implant-supported frameworks.

Authors:  Anna Gabriella Camacho Presotto; Cláudia Lopes Brilhante Bhering; Marcelo Ferraz Mesquita; Valentim Adelino Ricardo Barão
Journal:  J Prosthet Dent       Date:  2016-09-22       Impact factor: 3.426

8.  Precision of fit of implant-supported screw-retained 10-unit computer-aided-designed and computer-aided-manufactured frameworks made from zirconium dioxide and titanium: an in vitro study.

Authors:  Joannis Katsoulis; Regina Mericske-Stern; Lolita Rotkina; Christoph Zbären; Norbert Enkling; Markus B Blatz
Journal:  Clin Oral Implants Res       Date:  2012-10-02       Impact factor: 5.977

9.  Variation in the total lengths of abutment/implant assemblies generated with a function of applied tightening torque in external and internal implant-abutment connection.

Authors:  Ki-Seong Kim; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon; Jae-Ho Yang; Jai-Bong Lee; Soon-Ho Yim
Journal:  Clin Oral Implants Res       Date:  2010-12-29       Impact factor: 5.977

10.  The effect of commercially pure titanium and alternative dental alloys on the marginal fit of one-piece cast implant frameworks.

Authors:  Erica Miranda de Torres; Renata Cristina Silveira Rodrigues; Maria da Gloria Chiarello de Mattos; Ricardo Faria Ribeiro
Journal:  J Dent       Date:  2007-09-06       Impact factor: 4.379

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.