Literature DB >> 17825466

The effect of commercially pure titanium and alternative dental alloys on the marginal fit of one-piece cast implant frameworks.

Erica Miranda de Torres1, Renata Cristina Silveira Rodrigues, Maria da Gloria Chiarello de Mattos, Ricardo Faria Ribeiro.   

Abstract

OBJECTIVES: The purpose of this study was to measure and compare the passive fit and vertical fit of one-piece cast frameworks fabricated with three different materials: commercially pure titanium (CP Ti), cobalt-chromium alloy (Co-Cr) and nickel-chromium-titanium alloy (Ni-Cr-Ti).
METHODS: Fifteen frameworks simulating bars for fixed prosthesis in a model with five implants were fabricated and arranged into three different groups according to the material used. The fit of the framework abutment interface was measured using an optical microscope, when only one screw was manually tightened at a terminal abutment (passive fit) or when all framework screws were tightened to 10 N cm torque (vertical fit). Data were statistically analyzed using Kruskal-Wallis and Mann-Whitney tests (alpha=0.05).
RESULTS: Mean and standard deviation values of passive fit and vertical fit are presented, respectively: CP Ti [88 (74) microm and 22 (9) microm], Co-Cr [229 (184) microm and 66 (35) microm], Ni-Cr-Ti [200 (175) microm and 32 (24) microm]. There were no significant differences between passive fit of Co-Cr and Ni-Cr-Ti frameworks (p=0.313), but both alloys were statistically different from CP Ti (p<0.001 and 0.035, respectively), which showed the best results. As for vertical fit, CP Ti and Ni-Cr-Ti alloy were statistically similar (p=0.162) and they presented a better vertical fit than Co-Cr alloy (p<0.001).
CONCLUSIONS: Within the limitations of this study, it was possible to conclude that one-piece cast frameworks resulted in unacceptable passive fit and vertical fit, no matter which material had been used to fabricate them. However, the best results were obtained using CP Ti followed by Ni-Cr-Ti and Co-Cr alloys, respectively.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17825466     DOI: 10.1016/j.jdent.2007.07.013

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  7 in total

1.  Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling.

Authors:  Begoña Oteiza-Galdón; Amparo Martínez-González; Ángel-Vicente Escuder
Journal:  J Clin Exp Dent       Date:  2020-10-01

2.  Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study.

Authors:  Pedro Molinero-Mourelle; Rocio Cascos-Sanchez; Burak Yilmaz; Walter Yu Hang Lam; Edmond Ho Nang Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

3.  Sealing Capability and SEM Observation of the Implant-Abutment Interface.

Authors:  Fabio C Lorenzoni; Paulo G Coelho; Gerson Bonfante; Ricardo M Carvalho; Nelson R F A Silva; Marcelo Suzuki; Thelma Lopes Silva; Estevam A Bonfante
Journal:  Int J Dent       Date:  2011-07-02

4.  Evaluation of marginal and internal gaps of Ni-Cr and Co-Cr alloy copings manufactured by microstereolithography.

Authors:  Dong-Yeon Kim; Chong-Myeong Kim; Ji-Hwan Kim; Hae-Young Kim; Woong-Chul Kim
Journal:  J Adv Prosthodont       Date:  2017-06-19       Impact factor: 1.904

5.  Marginal Discrepancy of Single Implant-Supported Metal Copings Fabricated by Various CAD/CAM and Conventional Techniques Using Different Materials.

Authors:  Safoura Ghodsi; Marzieh Alikhasi; Nika Soltani
Journal:  Eur J Dent       Date:  2019-11-26

6.  Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses.

Authors:  Thaís Barbin; Letícia Del Rio Silva; Daniele Valente Velôso; Guilherme Almeida Borges; Anna Gabriella Camacho Presotto; Valentim Adelino Ricardo Barão; Francisco Carlos Groppo; Marcelo Ferraz Mesquita
Journal:  J Adv Prosthodont       Date:  2020-12-28       Impact factor: 1.904

7.  Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.

Authors:  Per Svanborg; Victoria Stenport; Alf Eliasson
Journal:  Clin Exp Dent Res       Date:  2015-10-26
  7 in total