Literature DB >> 22093362

Effect of vertical misfit on strain within screw-retained implant titanium and zirconia frameworks.

Jaafar Abduo1, Karl Lyons.   

Abstract

PURPOSE: To assess the implication of vertical misfit on strain within implant frameworks manufactured in titanium or zirconia.
METHODS: A master model was fabricated by inserting a Brånemark implant in left side of a mandibular model in the area of the first premolar and the first molar. This model was used to fabricate identical frameworks, five in titanium and five in zirconia. A single strain gauge was mounted on the occlusal surface of each framework to assess strain development as a result of framework fitting. In addition, the peak-to-peak strain amplitude was measured for each framework to determine the strain pattern fluctuation. The vertical gap of the framework-implant interface was measured using a measuring microscope, when only one screw was tightened (1-screw test) and when both screws were tightened (2-screw test). The vertical fit of the frameworks was altered by adding one to three layers of 30 μm steel shims on one of the implants.
RESULTS: For all fitting conditions, measurable amount of strains were recorded, however, as the vertical misfit was introduced, linear increase in framework strain was detected. The titanium and zirconia frameworks exhibited similar strain activities. A direct relationship was observed between the framework strain and vertical gap.
CONCLUSIONS: Framework misfit clearly influenced the framework strain magnitude and pattern. The framework material did not affect the framework strain for a similar level of misfit. Crown
Copyright © 2011. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 22093362     DOI: 10.1016/j.jpor.2011.09.001

Source DB:  PubMed          Journal:  J Prosthodont Res        ISSN: 1883-1958            Impact factor:   4.642


  5 in total

1.  Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling.

Authors:  Begoña Oteiza-Galdón; Amparo Martínez-González; Ángel-Vicente Escuder
Journal:  J Clin Exp Dent       Date:  2020-10-01

2.  Realization of a Dental Framework by 3D Printing in Material Cobalt-Chromium with Superior Precision and Fitting Accuracy.

Authors:  André Edelmann; Lisa Riedel; Ralf Hellmann
Journal:  Materials (Basel)       Date:  2020-11-27       Impact factor: 3.623

3.  Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses.

Authors:  Thaís Barbin; Letícia Del Rio Silva; Daniele Valente Velôso; Guilherme Almeida Borges; Anna Gabriella Camacho Presotto; Valentim Adelino Ricardo Barão; Francisco Carlos Groppo; Marcelo Ferraz Mesquita
Journal:  J Adv Prosthodont       Date:  2020-12-28       Impact factor: 1.904

4.  Fit of cobalt-chromium implant frameworks before and after ceramic veneering in comparison with CNC-milled titanium frameworks.

Authors:  Per Svanborg; Victoria Stenport; Alf Eliasson
Journal:  Clin Exp Dent Res       Date:  2015-10-26

5.  Accuracy of fit of implant-supported bars fabricated on definitive casts made by different dental stones.

Authors:  Ioannis Kioleoglou; Argirios Pissiotis; Michalakis Konstantinos
Journal:  J Clin Exp Dent       Date:  2018-03-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.