Literature DB >> 20976408

Use of base metal casting alloys for implant framework: marginal accuracy analysis.

Stefania Carvalho Kano1, Gerson Bonfante, Raquel Hussne, Aline F Siqueira.   

Abstract

The original protocol for implant prosthesis recommends the use of a gold framework for acrylic and ceramic prosthesis. However, due to its high cost, the use of alternative alloys is desired. This study compares the marginal accuracy of pre-made cylinders versus plastic cylinders cast with two different base metal casting alloys. Five samples each of (1) plastic cylinder cast in cobalt-chromium alloy, (2) plastic cylinder cast in nickel-chromium alloy, and (3) silver-palladium pre-made cylinder (control) were examined for marginal accuracy according to: (A) vertical gap; (B) horizontal gap and (C) horizontal gap depth at the abutment/cylinder interface. Data were submitted to statistical analysis (ANOVA and Student-Newman Keuls, p<0.05). Mean values for vertical, horizontal and gap depth were 4.13µm, 14.5µm and 6.93µm for pre-made cylinder, 23.18µm, 33.2µm and 88µm for Ni-Cr cast cylinder and 25.6µm, 51.8µm and 114.54µm for Co-Cr cast cylinder. No statistically significant differences were found between cast groups (1 and 2), but significant better fit was obtained with pre-made metal cylinders when compared to cast cylinders with Ni-Cr and Co-Cr alloys, for all analyses.

Entities:  

Year:  2004        PMID: 20976408     DOI: 10.1590/s1678-77572004000400016

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


  6 in total

1.  Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling.

Authors:  Begoña Oteiza-Galdón; Amparo Martínez-González; Ángel-Vicente Escuder
Journal:  J Clin Exp Dent       Date:  2020-10-01

2.  Effect of axial loads on implant-supported partial fixed prostheses by strain gauge analysis.

Authors:  Luis Gustavo Oliveira de Vasconcellos; Renato Sussumu Nishioka; Luana Marotta Reis de Vasconcellos; Lea Nogueira Braulino de Melo Nishioka
Journal:  J Appl Oral Sci       Date:  2011 Nov-Dec       Impact factor: 2.698

3.  Effect of cyclic load on vertical misfit of prefabricated and cast implant single abutment.

Authors:  Rudys Rodolfo de Jesus Tavarez; Wellington Cardoso Bonachela; Anuar Antônio Xible
Journal:  J Appl Oral Sci       Date:  2011 Jan-Feb       Impact factor: 2.698

4.  Effect of 0.2% peracetic acid disinfection on the horizontal dimension of implant framework indexed with two autopolymerized acrylic resins.

Authors:  Emanuely Ronconi da Fonseca; Paula Pereira Santana; Anuar Antonio Xible; Donald A Curtis; Stefania Carvalho Kano
Journal:  Int J Implant Dent       Date:  2019-09-18

5.  Accuracy combining different brands of implants and abutments.

Authors:  María-Fernanda Solá-Ruíz; Eduardo Selva-Otaolaurruchi; Gisela Senent-Vicente; Inés González-de-Cossio; Vicente Amigó-Borrás
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2013-03-01

6.  Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis.

Authors:  Izabela C M Moris; Silas Borges Monteiro; Raíssa Martins; Ricardo Faria Ribeiro; Erica A Gomes
Journal:  Biomed Res Int       Date:  2018-01-23       Impact factor: 3.411

  6 in total