Literature DB >> 27666497

Marginal fit and photoelastic stress analysis of CAD-CAM and overcast 3-unit implant-supported frameworks.

Anna Gabriella Camacho Presotto1, Cláudia Lopes Brilhante Bhering2, Marcelo Ferraz Mesquita3, Valentim Adelino Ricardo Barão4.   

Abstract

STATEMENT OF PROBLEM: Several studies have shown the superiority of computer-assisted design and computer-assisted manufacturing (CAD-CAM) technology compared with conventional casting. However, an advanced technology exists for casting procedures (the overcasting technique), which may serve as an acceptable and affordable alternative to CAD-CAM technology for fabricating 3-unit implant-supported fixed dental prostheses (FDPs).
PURPOSE: The purpose of this in vitro study was to evaluate, using quantitative photoelastic analysis, the effect of the prosthetic framework fabrication method (CAD-CAM and overcasting) on the marginal fit and stress transmitted to implants. The correlation between marginal fit and stress was also investigated.
MATERIAL AND METHODS: Three-unit implant-supported FDP frameworks were made using the CAD-CAM (n=10) and overcasting (n=10) methods. The frameworks were waxed to simulate a mandibular first premolar (PM region) to first molar (M region) FDP using overcast mini-abutment cylinders. The wax patterns were overcast (overcast experimental group) or scanned to obtain the frameworks (CAD-CAM control group). All frameworks were fabricated from cobalt-chromium (CoCr) alloy. The marginal fit was analyzed according to the single-screw test protocol, obtaining an average value for each region (M and PM) and each framework. The frameworks were tightened for the photoelastic model with standardized 10-Ncm torque. Stress was measured by quantitative photoelastic analysis. The results were submitted to the Student t test, 2-way ANOVA, and Pearson correlation test (α=.05).
RESULTS: The framework fabrication method (FM) and evaluation site (ES; M and PM regions) did not affect the marginal fit values (P=.559 for FM and P=.065 for ES) and stress (P=.685 for FM and P=.468 for ES) in the implant-supported system. Positive correlations between marginal fit and stress were observed (CAD-CAM: r=0.922; P<.001; overcast: r=0.908; P<.001).
CONCLUSIONS: CAD-CAM and overcasting methods present similar marginal fit and stress values for 3-unit FDP frameworks. The decreased marginal fit of frameworks induces greater stress in the implant-supported system.
Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Mesh:

Substances:

Year:  2016        PMID: 27666497     DOI: 10.1016/j.prosdent.2016.06.011

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  7 in total

1.  Analysis of fit on implants of chrome cobalt versus titanium frameworks made by cad / cam milling.

Authors:  Begoña Oteiza-Galdón; Amparo Martínez-González; Ángel-Vicente Escuder
Journal:  J Clin Exp Dent       Date:  2020-10-01

2.  Conical connection adjustment in prosthetic abutments obtained by different techniques.

Authors:  Roser Camós-Tena; Tomás Escuin-Henar; Sergi Torné-Duran
Journal:  J Clin Exp Dent       Date:  2019-05-01

3.  Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses.

Authors:  Thaís Barbin; Letícia Del Rio Silva; Daniele Valente Velôso; Guilherme Almeida Borges; Anna Gabriella Camacho Presotto; Valentim Adelino Ricardo Barão; Francisco Carlos Groppo; Marcelo Ferraz Mesquita
Journal:  J Adv Prosthodont       Date:  2020-12-28       Impact factor: 1.904

4.  Titanium Base Abutments in Implant Prosthodontics: A Literature Review.

Authors:  Ahmad M Al-Thobity
Journal:  Eur J Dent       Date:  2021-11-18

Review 5.  New generation CAD-CAM materials for implant-supported definitive frameworks fabricated by using subtractive technologies.

Authors:  Pinar Cevik; Martin Schimmel; Burak Yilmaz
Journal:  Biomed Res Int       Date:  2022-03-02       Impact factor: 3.411

Review 6.  Photoelasticity for Stress Concentration Analysis in Dentistry and Medicine.

Authors:  Miriam Marín-Miranda; Ana María Wintergerst; Yoshamin Abnoba Moreno-Vargas; María Lilia Adriana Juárez-López; Cesar Tavera-Ruiz
Journal:  Materials (Basel)       Date:  2022-09-30       Impact factor: 3.748

7.  A prospective clinical study on implant impression accuracy.

Authors:  Motaz Osman; Hassan Ziada; Ahmed Suliman; Neamat Hassan Abubakr
Journal:  Int J Implant Dent       Date:  2019-11-19
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.