Technical Note: 4D cone-beam CT reconstruction from sparse-view CBCT data for daily motion assessment in pencil beam scanned proton therapy (PBS-PT).

Lydia A den Otter1, Kuanling Chen2, Guillaume Janssens3, Arturs Meijers1, Stefan Both1, Johannes A Langendijk1, Lane R Rosen2, Hsinshun T Wu2, Antje-Christin Knopf1.   

Abstract

PURPOSE: The number of pencil beam scanned proton therapy (PBS-PT) facilities equipped with cone-beam computed tomography (CBCT) imaging treating thoracic indications is constantly rising. To enable daily internal motion monitoring during PBS-PT treatments of thoracic tumors, we assess the performance of Motion-Aware RecOnstructiOn method using Spatial and Temporal Regularization (MA-ROOSTER) four-dimensional CBCT (4DCBCT) reconstruction for sparse-view CBCT data and a realistic data set of patients treated with proton therapy.
METHODS: Daily CBCT projection data for nine non-small cell lung cancer (NSCLC) patients and one SCLC patient were acquired at a proton gantry system (IBA Proteus® One). Four-dimensional CBCT images were reconstructed applying the MA-ROOSTER and the conventional phase-correlated Feldkamp-Davis-Kress (PC-FDK) method. Image quality was assessed by visual inspection, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), and the structural similarity index measure (SSIM). Furthermore, gross tumor volume (GTV) centroid motion amplitudes were evaluated.
RESULTS: Image quality for the 4DCBCT reconstructions using MA-ROOSTER was superior to the PC-FDK reconstructions and close to FDK images (median CNR: 1.23 [PC-FDK], 1.98 [MA-ROOSTER], and 1.98 [FDK]; median SNR: 2.56 [PC-FDK], 4.76 [MA-ROOSTER], and 5.02 [FDK]; median SSIM: 0.18 [PC-FDK vs FDK], 0.31 [MA-ROOSTER vs FDK]). The improved image quality of MA-ROOSTER facilitated GTV contour warping and realistic motion monitoring for most of the reconstructions.
CONCLUSION: MA-ROOSTER based 4DCBCTs performed well in terms of image quality and appear to be promising for daily internal motion monitoring in PBS-PT treatments of (N)SCLC patients.
© 2020 The Authors. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine.

Entities:  

Keywords:  4D-CBCT; Lung cancer; image reconstruction; inter-fractional motion; pencil beam scanning; proton therapy

Mesh:

Year:  2020        PMID: 33011990      PMCID: PMC7821169          DOI: 10.1002/mp.14521

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  19 in total

1.  Motion-map constrained image reconstruction (MCIR): application to four-dimensional cone-beam computed tomography.

Authors:  Justin C Park; Jin Sung Kim; Sung Ho Park; Zhaowei Liu; Bongyong Song; William Y Song
Journal:  Med Phys       Date:  2013-12       Impact factor: 4.071

2.  Prior image constrained compressed sensing (PICCS): a method to accurately reconstruct dynamic CT images from highly undersampled projection data sets.

Authors:  Guang-Hong Chen; Jie Tang; Shuai Leng
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

3.  On-the-fly motion-compensated cone-beam CT using an a priori model of the respiratory motion.

Authors:  Simon Rit; Jochem W H Wolthaus; Marcel van Herk; Jan-Jakob Sonke
Journal:  Med Phys       Date:  2009-06       Impact factor: 4.071

4.  The ANACONDA algorithm for deformable image registration in radiotherapy.

Authors:  Ola Weistrand; Stina Svensson
Journal:  Med Phys       Date:  2015-01       Impact factor: 4.071

Review 5.  Current state and future applications of radiological image guidance for particle therapy.

Authors:  Guillaume Landry; Chia-Ho Hua
Journal:  Med Phys       Date:  2018-11       Impact factor: 4.071

6.  Feasibility of 4DCBCT-based proton dose calculation: An ex vivo porcine lung phantom study.

Authors:  Katharina Niepel; Florian Kamp; Christopher Kurz; David Hansen; Simon Rit; Sebastian Neppl; Jan Hofmaier; David Bondesson; Christian Thieke; Julien Dinkel; Claus Belka; Katia Parodi; Guillaume Landry
Journal:  Z Med Phys       Date:  2018-11-14       Impact factor: 4.820

7.  Dosimetric evaluation of 4D-CBCT reconstructed by Simultaneous Motion Estimation and Image Reconstruction (SMEIR) for carbon ion therapy of lung cancer.

Authors:  Deepak Shrestha; Min-Yu Tsai; Nan Qin; You Zhang; Xun Jia; Jing Wang
Journal:  Med Phys       Date:  2019-07-31       Impact factor: 4.071

8.  Towards imaging the beating heart usefully with a conventional CT scanner.

Authors:  G C Mc Kinnon; R H Bates
Journal:  IEEE Trans Biomed Eng       Date:  1981-02       Impact factor: 4.538

9.  SPARE: Sparse-view reconstruction challenge for 4D cone-beam CT from a 1-min scan.

Authors:  Chun-Chien Shieh; Yesenia Gonzalez; Bin Li; Xun Jia; Simon Rit; Cyril Mory; Matthew Riblett; Geoffrey Hugo; Yawei Zhang; Zhuoran Jiang; Xiaoning Liu; Lei Ren; Paul Keall
Journal:  Med Phys       Date:  2019-07-19       Impact factor: 4.071

10.  High temporal resolution and streak-free four-dimensional cone-beam computed tomography.

Authors:  Shuai Leng; Jie Tang; Joseph Zambelli; Brian Nett; Ranjini Tolakanahalli; Guang-Hong Chen
Journal:  Phys Med Biol       Date:  2008-09-24       Impact factor: 3.609

View more
  1 in total

Review 1.  Management of Motion and Anatomical Variations in Charged Particle Therapy: Past, Present, and Into the Future.

Authors:  Julia M Pakela; Antje Knopf; Lei Dong; Antoni Rucinski; Wei Zou
Journal:  Front Oncol       Date:  2022-03-09       Impact factor: 6.244

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.