On-the-fly motion-compensated cone-beam CT using an a priori model of the respiratory motion.

Simon Rit1, Jochem W H Wolthaus, Marcel van Herk, Jan-Jakob Sonke.   

Abstract

Respiratory motion causes artifacts in cone-beam (CB) CT images acquired on slow rotating scanners integrated with linear accelerators. Respiration-correlated CBCT has been proposed to correct for the respiratory motion but only a subset of the CB projections is used to reconstruct each frame of the 4D CBCT image and, therefore, adequate image quality requires long acquisition times. In this article, the authors develop an on-the-fly solution to estimate and compensate for the respiratory motion in the reconstruction of a 3D CBCT image from all the CB projections. An a priori motion model of the patient respiratory cycle is estimated from the 4D planning CT. During the acquisition, the model is correlated with the respiration using a respiratory signal extracted from the CB projections. The estimated motion is next compensated for in an optimized reconstruction algorithm. The motion compensated for is forced to be null on average over the acquisition time to ensure that the compensation results in a CBCT image which describes the mean position of each organ, even if the a priori motion model is inaccurate. Results were assessed on simulated, phantom, and patient data. In all experiments, blur was visually reduced by motion-compensated CBCT. Simulations showed robustness to inaccuracies of the motion model observed on patient data such as amplitude variations, phase shifts, and setup errors, thus proving the efficiency of the compensation using an a priori motion model. Noise and view-aliasing artifacts were lower on motion-compensated CBCT images with 1 min scan than on respiration-correlated CBCT images with 4 min scan. Finally, on-the-fly motion estimation and motion-compensated reconstruction were within the acquisition time of the CB projections and the CBCT image available a few seconds after the end of the acquisition. In conclusion, the authors developed and implemented a method for correcting the respiratory motion during the treatment fractions which can replace respiration-correlated CBCT for improving image quality while decreasing acquisition time.

Entities:  

Mesh:

Year:  2009        PMID: 19610317     DOI: 10.1118/1.3115691

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  36 in total

1.  4D Cone-beam CT reconstruction using a motion model based on principal component analysis.

Authors:  David Staub; Alen Docef; Robert S Brock; Constantin Vaman; Martin J Murphy
Journal:  Med Phys       Date:  2011-12       Impact factor: 4.071

2.  Extraction of tumor motion trajectories using PICCS-4DCBCT: a validation study.

Authors:  Zhihua Qi; Guang-Hong Chen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

3.  Image quality improvements in C-Arm CT (CACT) for liver oncology applications: preliminary study in rabbits.

Authors:  Vania Tacher; Nikhil Bhagat; Pramod V Rao; Mingde Lin; Dirk Schäfer; Niels Noordhoek; Peter Eshuis; Alessandro Radaelli; Eleni Liapi; Michael Grass; Jean-François Geschwind
Journal:  Minim Invasive Ther Allied Technol       Date:  2013-07-09       Impact factor: 2.442

4.  Autoadaptive phase-correlated (AAPC) reconstruction for 4D CBCT.

Authors:  Frank Bergner; Timo Berkus; Markus Oelhafen; Patrik Kunz; Tinsu Pan; Marc Kachelriess
Journal:  Med Phys       Date:  2009-12       Impact factor: 4.071

5.  A hybrid reconstruction algorithm for fast and accurate 4D cone-beam CT imaging.

Authors:  Hao Yan; Xin Zhen; Michael Folkerts; Yongbao Li; Tinsu Pan; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

6.  A method for volumetric imaging in radiotherapy using single x-ray projection.

Authors:  Yuan Xu; Hao Yan; Luo Ouyang; Jing Wang; Linghong Zhou; Laura Cervino; Steve B Jiang; Xun Jia
Journal:  Med Phys       Date:  2015-05       Impact factor: 4.071

7.  Target-specific optimization of four-dimensional cone beam computed tomography.

Authors:  Moiz Ahmad; Tinsu Pan
Journal:  Med Phys       Date:  2012-09       Impact factor: 4.071

8.  Accumulated dose in liver stereotactic body radiotherapy: positioning, breathing, and deformation effects.

Authors:  Michael Velec; Joanne L Moseley; Tim Craig; Laura A Dawson; Kristy K Brock
Journal:  Int J Radiat Oncol Biol Phys       Date:  2011-12-28       Impact factor: 7.038

9.  Cine cone beam CT reconstruction using low-rank matrix factorization: algorithm and a proof-of-principle study.

Authors:  Jian-Feng Cai; Xun Jia; Hao Gao; Steve B Jiang; Zuowei Shen; Hongkai Zhao
Journal:  IEEE Trans Med Imaging       Date:  2014-04-21       Impact factor: 10.048

10.  4D cone-beam computed tomography (CBCT) using a moving blocker for simultaneous radiation dose reduction and scatter correction.

Authors:  Cong Zhao; Yuncheng Zhong; Xinhui Duan; You Zhang; Xiaokun Huang; Jing Wang; Mingwu Jin
Journal:  Phys Med Biol       Date:  2018-05-29       Impact factor: 3.609