Literature DB >> 25563246

The ANACONDA algorithm for deformable image registration in radiotherapy.

Ola Weistrand1, Stina Svensson1.   

Abstract

PURPOSE: The purpose of this work was to describe a versatile algorithm for deformable image registration with applications in radiotherapy and to validate it on thoracic 4DCT data as well as CT/cone beam CT (CBCT) data.
METHODS: ANAtomically CONstrained Deformation Algorithm (ANACONDA) combines image information (i.e., intensities) with anatomical information as provided by contoured image sets. The registration problem is formulated as a nonlinear optimization problem and solved with an in-house developed solver, tailored to this problem. The objective function, which is minimized during optimization, is a linear combination of four nonlinear terms: 1. image similarity term; 2. grid regularization term, which aims at keeping the deformed image grid smooth and invertible; 3. a shape based regularization term which works to keep the deformation anatomically reasonable when regions of interest are present in the reference image; and 4. a penalty term which is added to the optimization problem when controlling structures are used, aimed at deforming the selected structure in the reference image to the corresponding structure in the target image.
RESULTS: To validate ANACONDA, the authors have used 16 publically available thoracic 4DCT data sets for which target registration errors from several algorithms have been reported in the literature. On average for the 16 data sets, the target registration error is 1.17 ± 0.87 mm, Dice similarity coefficient is 0.98 for the two lungs, and image similarity, measured by the correlation coefficient, is 0.95. The authors have also validated ANACONDA using two pelvic cases and one head and neck case with planning CT and daily acquired CBCT. Each image has been contoured by a physician (radiation oncologist) or experienced radiation therapist. The results are an improvement with respect to rigid registration. However, for the head and neck case, the sample set is too small to show statistical significance.
CONCLUSIONS: ANACONDA performs well in comparison with other algorithms. By including CT/CBCT data in the validation, the various aspects of the algorithm such as its ability to handle different modalities, large deformations, and air pockets are shown.

Entities:  

Mesh:

Year:  2015        PMID: 25563246     DOI: 10.1118/1.4894702

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  48 in total

1.  The VAMPIRE challenge: A multi-institutional validation study of CT ventilation imaging.

Authors:  John Kipritidis; Bilal A Tahir; Guillaume Cazoulat; Michael S Hofman; Shankar Siva; Jason Callahan; Nicholas Hardcastle; Tokihiro Yamamoto; Gary E Christensen; Joseph M Reinhardt; Noriyuki Kadoya; Taylor J Patton; Sarah E Gerard; Isabella Duarte; Ben Archibald-Heeren; Mikel Byrne; Rick Sims; Scott Ramsay; Jeremy T Booth; Enid Eslick; Fiona Hegi-Johnson; Henry C Woodruff; Rob H Ireland; Jim M Wild; Jing Cai; John E Bayouth; Kristy Brock; Paul J Keall
Journal:  Med Phys       Date:  2019-02-01       Impact factor: 4.071

2.  Biomechanical deformable image registration of longitudinal lung CT images using vessel information.

Authors:  Guillaume Cazoulat; Dawn Owen; Martha M Matuszak; James M Balter; Kristy K Brock
Journal:  Phys Med Biol       Date:  2016-06-08       Impact factor: 3.609

3.  BEM-based simulation of lung respiratory deformation for CT-guided biopsy.

Authors:  Dong Chen; Weisheng Chen; Lipeng Huang; Xuegang Feng; Terry Peters; Lixu Gu
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-05-10       Impact factor: 2.924

4.  Comparison of predictive performance for toxicity by accumulative dose of DVH parameter addition and DIR addition for cervical cancer patients.

Authors:  Yuya Miyasaka; Noriyuki Kadoya; Rei Umezawa; Yoshiki Takayama; Kengo Ito; Takaya Yamamoto; Shohei Tanaka; Suguru Dobashi; Ken Takeda; Kenji Nemoto; Takeo Iwai; Keiichi Jingu
Journal:  J Radiat Res       Date:  2021-01-01       Impact factor: 2.724

5.  Validation of biomechanical deformable image registration in the abdomen, thorax, and pelvis in a commercial radiotherapy treatment planning system.

Authors:  Michael Velec; Joanne L Moseley; Stina Svensson; Björn Hårdemark; David A Jaffray; Kristy K Brock
Journal:  Med Phys       Date:  2017-06-01       Impact factor: 4.071

6.  Biomechanical modeling of neck flexion for deformable alignment of the salivary glands in head and neck cancer images.

Authors:  Molly M McCulloch; Brian M Anderson; Guillaume Cazoulat; Christine B Peterson; Abdallah S R Mohamed; Stefania Volpe; Hesham Elhalawani; Houda Bahig; Bastien Rigaud; Jason B King; Alexandra C Ford; Clifton D Fuller; Kristy K Brock
Journal:  Phys Med Biol       Date:  2019-09-05       Impact factor: 3.609

7.  Accuracy of deformable image registration techniques for alignment of longitudinal cholangiocarcinoma CT images.

Authors:  Anando Sen; Brian M Anderson; Guillaume Cazoulat; Molly M McCulloch; Dalia Elganainy; Brigid A McDonald; Yulun He; Abdallah S R Mohamed; Baher A Elgohari; Mohamed Zaid; Eugene J Koay; Kristy K Brock
Journal:  Med Phys       Date:  2020-02-12       Impact factor: 4.071

8.  Quantification of plan robustness against different uncertainty sources for classical and anatomical robust optimized treatment plans in head and neck cancer proton therapy.

Authors:  Macarena Cubillos-Mesías; Esther G C Troost; Fabian Lohaus; Linda Agolli; Maximilian Rehm; Christian Richter; Kristin Stützer
Journal:  Br J Radiol       Date:  2019-11-28       Impact factor: 3.039

9.  Evaluation of radiotherapy techniques for radical treatment of lateralised oropharyngeal cancers : Dosimetry and NTCP.

Authors:  D McQuaid; A Dunlop; S Nill; C Franzese; C M Nutting; K J Harrington; K L Newbold; S A Bhide
Journal:  Strahlenther Onkol       Date:  2016-06-13       Impact factor: 3.621

10.  Hyperpolarized 129Xe Magnetic Resonance Imaging for Functional Avoidance Treatment Planning in Thoracic Radiation Therapy: A Comparison of Ventilation- and Gas Exchange-Guided Treatment Plans.

Authors:  Leith J Rankine; Ziyi Wang; Chris R Kelsey; Elianna Bier; Bastiaan Driehuys; Lawrence B Marks; Shiva K Das
Journal:  Int J Radiat Oncol Biol Phys       Date:  2021-07-13       Impact factor: 7.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.