BACKGROUND: Studies comparing cementless and cemented cups are lacking, especially for revision total hip arthroplasty (THA). The aim of this study was to investigate and compare the differences in implant accuracy between two fixation methods in revision THA.
METHODS: We conducted a retrospective study of 85 hips in 70 patients who underwent revision THA using a computed tomography (CT)-based navigation system. Among these, 53 hips underwent cementless THA and 32 hips underwent cemented THA. We measured cup inclination and anteversion using the Kyocera two-dimensional-template with X-ray (Japan-Kyocera, Shiga, Japan) and stem anteversion with CT. We calculated the combined anteversion [cup anteversion+0.7×stem anteversion].
RESULTS: There were no significant differences between the two groups with respect to definitive cup inclination and anteversion. The mean deviations in the inclination and anteversion angle were 40.3 ± 4.3 and 19.6 ± 6.2° in the cementless group and 40.5 ± 3.3 and 17.1 ± 5.1° in the cemented group. There were 11 outliers with respect to the Lewinnek safe zone in the cementless group and two in the cemented group (P = 0.072). Although there was no statistically significant difference, the number of safe zone outliers in the cemented group was less than that in the cementless group.
CONCLUSION: We conclude that when using a navigation system for revision THA, high precision can be obtained for the cup placement angle with or without cement. However, it seems that a major error in the installation angle of the cup is less likely to occur when using a cemented cup than when using a cementless cup in revision THA with a navigation system.
© 2019 Delhi Orthopedic Association. All rights reserved.

Entities:  

Keywords:  CT-Based navigation; Cemented cup; Cementless cup; Revision THA

Year:  2019        PMID: 32189941      PMCID: PMC7067992          DOI: 10.1016/j.jcot.2019.05.021

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  19 in total

1.  Modular revision for recurrent dislocation of primary or revision total hip arthroplasty.

Authors:  Paul F Lachiewicz; Elizabeth Soileau; John Ellis
Journal:  J Arthroplasty       Date:  2004-06       Impact factor: 4.757

2.  A pilot project for the Japan arthroplasty register.

Authors:  Haruhiko Akiyama; Akiho Hoshino; Hirokazu Iida; Hiroyuki Shindo; Yoshinori Takakura; Hiromasa Miura; Kengo Yamamoto; Shinichi Yoshiya; Yukiharu Hasegawa; Tadashi Shimamura; Masahiro Kurosaka; Hiromi Otsuka; Keiichi Kawanabe; Kenji Kawate; Yoshitada Harada; Takashi Nakamura
Journal:  J Orthop Sci       Date:  2012-06-14       Impact factor: 1.601

Review 3.  Concerns about ceramics in THA.

Authors:  Robert L Barrack; Corey Burak; Harry B Skinner
Journal:  Clin Orthop Relat Res       Date:  2004-12       Impact factor: 4.176

4.  Impingement in total hip arthroplasty a study of retrieved acetabular components.

Authors:  Won Yong Shon; Todd Baldini; Margaret G Peterson; Timothy M Wright; Eduardo A Salvati
Journal:  J Arthroplasty       Date:  2005-06       Impact factor: 4.757

5.  Evaluation of the accuracy of computed tomography-based navigation for femoral stem orientation and leg length discrepancy.

Authors:  Makoto Kitada; Nobuo Nakamura; Daiki Iwana; Akihiro Kakimoto; Takashi Nishii; Nobuhiko Sugano
Journal:  J Arthroplasty       Date:  2010-09-25       Impact factor: 4.757

6.  Comparison of cemented vs uncemented acetabular component positioning using an imageless navigation system.

Authors:  Mayur Chawda; Peter Hucker; Sarah L Whitehouse; Ross W Crawford; Hugh English; William J Donnelly
Journal:  J Arthroplasty       Date:  2008-12-04       Impact factor: 4.757

7.  Effect of reduced diameter neck stem on incidence of radiographic cup loosening and revisions in Charnley low-frictional torque arthroplasty.

Authors:  B Michael Wroblewski; Paul D Siney; Patricia A Fleming
Journal:  J Arthroplasty       Date:  2008-04-11       Impact factor: 4.757

8.  Cementation of a Dual Mobility Construct in Recurrently Dislocating and High Risk Patients Undergoing Revision Total Arthroplasty.

Authors:  Brian P Chalmers; Cameron K Ledford; Michael J Taunton; Rafael J Sierra; David G Lewallen; Robert T Trousdale
Journal:  J Arthroplasty       Date:  2017-12-06       Impact factor: 4.757

9.  Revision Total Hip Arthroplasty Using Imageless Navigation With the Concept of Combined Anteversion.

Authors:  Jun-Dong Chang; In-Sung Kim; Sharad Prabhakar; Sameer A Mansukhani; Sang-Soo Lee; Je-Hyun Yoo
Journal:  J Arthroplasty       Date:  2016-12-27       Impact factor: 4.757

10.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

View more
  1 in total

1.  Smartphone Application Helps Improve the Accuracy of Cup Placement by Young, Less-Experienced Surgeons during Primary Total Hip Arthroplasty.

Authors:  Ahmed A Khalifa; Mohammad K Abdelnasser; Ahmed M Ahmed; Gautam M Shetty; Ahmed M Abdelaal
Journal:  Arch Bone Jt Surg       Date:  2022-03
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.