Literature DB >> 35514765

Smartphone Application Helps Improve the Accuracy of Cup Placement by Young, Less-Experienced Surgeons during Primary Total Hip Arthroplasty.

Ahmed A Khalifa1, Mohammad K Abdelnasser2, Ahmed M Ahmed1, Gautam M Shetty3, Ahmed M Abdelaal2.   

Abstract

Background: Dislocation after total hip arthroplasty (THA) partly under the surgeon's control, by appropriate placement of the components. We aimed in this study to determine the accuracy of using intra-operative smartphone applications (Apps) to place the acetabular cup within the safe abduction angle by less experienced surgeons during THA surgery when compared to the conventional freehand technique for cup placement.
Methods: Sixty primary THAs were performed, 30 using the conventional freehand technique (control group) and 30 using the smartphone app technique (study group) to determine the acetabular cup abduction angle by the same young surgeon with less than one year of experience. Postoperative mean cup abduction angle, mean cup anteversion angle, and the percentage of cups within the safe abduction zone as measured on radiographs were compared between the two groups.
Results: In the study group, the mean cup abduction angle was significantly lower (P=0.0008), and the acetabular cup was placed within the safe zone in a significantly higher (P<0.001) percentage of patients (93% vs 63%) when compared to the control group. However, there was no significant difference (P=0.40) between the two groups when the mean cup anteversion angle was compared.
Conclusion: The smartphone app technique may help achieve an accurate acetabular cup abduction angle and a higher percentage of cups placed within the safe zone of abduction by a less experienced surgeon when compared to the conventional freehand technique. Using tools such as the smartphone app to measure the acetabular cup position can reduce intraoperative errors by young and less experienced surgeons during THA surgery.

Entities:  

Keywords:  Lewinnek safe zone; Total hip arthroplasty; acetabular cup; smartphone; total hip replacement

Year:  2022        PMID: 35514765      PMCID: PMC9034791          DOI: 10.22038/ABJS.2021.52402.2587

Source DB:  PubMed          Journal:  Arch Bone Jt Surg        ISSN: 2345-461X


  24 in total

1.  Improving acetabular cup orientation in total hip arthroplasty by using smartphone technology.

Authors:  Frank M Peters; Richard Greeff; Neal Goldstein; Chris T Frey
Journal:  J Arthroplasty       Date:  2012-01-14       Impact factor: 4.757

2.  The transverse acetabular ligament: an aid to orientation of the acetabular component during primary total hip replacement: a preliminary study of 1000 cases investigating postoperative stability.

Authors:  H A P Archbold; B Mockford; D Molloy; J McConway; L Ogonda; D Beverland
Journal:  J Bone Joint Surg Br       Date:  2006-07

3.  What are the causes for failures of primary hip arthroplasties in France?

Authors:  Christian Delaunay; Moussa Hamadouche; Julien Girard; Alain Duhamel
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

4.  The 2014 Frank Stinchfield Award: The 'landing zone' for wear and stability in total hip arthroplasty is smaller than we thought: a computational analysis.

Authors:  Jacob M Elkins; John J Callaghan; Thomas D Brown
Journal:  Clin Orthop Relat Res       Date:  2015-02       Impact factor: 4.176

5.  Factors predisposing to dislocation after primary total hip arthroplasty: a multivariate analysis.

Authors:  B M Jolles; P Zangger; P-F Leyvraz
Journal:  J Arthroplasty       Date:  2002-04       Impact factor: 4.757

6.  Photographic measurement of the inclination of the acetabular component in total hip replacement using the posterior approach.

Authors:  J C Hill; D P Gibson; R Pagoti; D E Beverland
Journal:  J Bone Joint Surg Br       Date:  2010-09

7.  The John Charnley Award: risk factors for cup malpositioning: quality improvement through a joint registry at a tertiary hospital.

Authors:  Mark C Callanan; Bryan Jarrett; Charles R Bragdon; David Zurakowski; Harry E Rubash; Andrew A Freiberg; Henrik Malchau
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

8.  Acetabular polyethylene wear and acetabular inclination and femoral offset.

Authors:  Nick J Little; Constant A Busch; John A Gallagher; Cecil H Rorabeck; Robert B Bourne
Journal:  Clin Orthop Relat Res       Date:  2009-05-02       Impact factor: 4.176

9.  Use of iPhone technology in improving acetabular component position in total hip arthroplasty.

Authors:  Xiau Wei Tay; Benny Xu Zhang; George Gayagay
Journal:  Arthroplast Today       Date:  2017-06-24

10.  The risk of revision due to dislocation after total hip arthroplasty depends on surgical approach, femoral head size, sex, and primary diagnosis. An analysis of 78,098 operations in the Swedish Hip Arthroplasty Register.

Authors:  Nils P Hailer; Rüdiger J Weiss; André Stark; Johan Kärrholm
Journal:  Acta Orthop       Date:  2012-10-08       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.