Literature DB >> 18534443

Effect of reduced diameter neck stem on incidence of radiographic cup loosening and revisions in Charnley low-frictional torque arthroplasty.

B Michael Wroblewski1, Paul D Siney, Patricia A Fleming.   

Abstract

Previous studies of the Charnley low-frictional torque arthroplasty have established an exponential correlation between the depth of cup penetration and the incidence of ultrahigh molecular weight polyethylene cemented cup migration. Impingement of the neck of the stem on the rim of the cup was considered to be the cause. We compared the incidence of radiographic loosening and revision of the cup in 2 groups of patients: those with 12.5-mm-diameter neck stem (972 hips) and those with 10-mm-diameter neck stem (261 hips) over a 20-year period, at comparable depths of cup penetration. The benefit of the 10-mm-diameter neck could be expressed as delaying radiographic loosening and revision of the cup by approximately 2 mm of cup penetration because loosening occurred at 2 mm penetration with a 12.5-mm-diameter neck but not until 4-mm penetration with a 10-mm-diameter neck. When a particular depth of cup penetration is reached will clearly depend on factors affecting wear.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18534443     DOI: 10.1016/j.arth.2008.01.312

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Does CT-based navigation improve the long-term survival in ceramic-on-ceramic THA?

Authors:  Nobuhiko Sugano; Masaki Takao; Takashi Sakai; Takashi Nishii; Hidenobu Miki
Journal:  Clin Orthop Relat Res       Date:  2012-11       Impact factor: 4.176

2.  A forty millimetre head significantly improves range of motion compared with a twenty eight millimetre head in total hip arthroplasty using a computed tomography-based navigation system.

Authors:  Kosuke Tsuda; Keiji Haraguchi; Junichiro Koyanagi; Shintaro Takahashi; Ryo Sugama; Keiju Fujiwara
Journal:  Int Orthop       Date:  2016-01-18       Impact factor: 3.075

3.  Accuracy of Acetabular Cup Placement During Total Hip Arthroplasty in Supine Position Using a Pelvic Rotation Correction Device.

Authors:  Satoshi Nakasone; Mika Takaesu; Masato Ishihara; Masamichi Onaga; Takahiro Igei; Yoshihide Miyata; Kotaro Nishida
Journal:  Arthroplast Today       Date:  2022-05-23

4.  Comparison of cementless and cemented cups in revision total hip arthroplasty using a computed tomography-based navigation system.

Authors:  Hiroaki Tagomori; Nobuhiro Kaku; Tomonori Tabata; Yuta Kubota; Hiroshi Tsumura
Journal:  J Clin Orthop Trauma       Date:  2019-05-28

5.  Interobserver and Intraobserver Reliabilities of Three-Dimensional Postoperative Evaluation Software in Total Hip Arthroplasty.

Authors:  Kenta Konno; Shigeo Hagiwara; Junichi Nakamura; Yuya Kawarai; Sumihisa Orita; Yawara Eguchi; Seiji Ohtori
Journal:  Adv Orthop       Date:  2021-09-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.