Literature DB >> 28139342

Revision Total Hip Arthroplasty Using Imageless Navigation With the Concept of Combined Anteversion.

Jun-Dong Chang1, In-Sung Kim1, Sharad Prabhakar1, Sameer A Mansukhani1, Sang-Soo Lee2, Je-Hyun Yoo3.   

Abstract

BACKGROUND: The purpose of the study was to evaluate the implant positions and clinical results of revision total hip arthroplasty (THA) using an imageless navigation with the concept of combined anteversion.
METHODS: A total of 40 cementless revision THAs (24 men and 16 women) using an imageless navigation with the concept of combined anteversion were retrospectively evaluated. The concept of combined anteversion was applied in cup positioning based on Widmer's equation (cup anteversion + 0.7 × stem anteversion). The mean follow-up period was 80.7 months. Postoperatively, the inclination of the cup was evaluated on standard anteroposterior view of the radiograph, and the anteversion of the cup and femoral stem was evaluated using computed tomography scan. A cup inclination of 40° ± 10° and combined anteversion of the cup and femoral stem of 37° ± 10° based on Widmer's equation were regarded as the "safe zone."
RESULTS: The average anteversion of the revised femoral stems was 15.3° ± 2.9° (range, 9.5°-21.5°), whereas that of the remained femoral stems was 17.4° ± 9.7° (range, 4.2°-29.8°). The inclination, anteversion of the cup, and combined anteversion after revision THA were 42.3° ± 3.1° (range, 32.1°-48.2°), 25.0° ± 2.9° (range, 16.9°-29.5°), and 36.1° ± 3.4° (range, 27.2°-42.9°), respectively. Therefore, the position of the implants, relative to the safe zone, showed no outliers after the revision surgery. Neither dislocation nor osteolysis was observed after the surgery.
CONCLUSION: Favorable results of this study indicate that imageless navigation helps the surgeon in placing the components of revision THA in the safe zone. This study also shows that when this safe zone is consistently obtained, then no postoperative dislocations were observed in these patients over the 6-year follow-up period.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  combined anteversion; component position; computer-assisted orthopaedic surgery; imageless navigation; revision total hip arthroplasty

Mesh:

Year:  2016        PMID: 28139342     DOI: 10.1016/j.arth.2016.12.030

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  9 in total

1.  Can we trust combined anteversion and Lewinnek safe zone to avoid hip prosthesis dislocation?

Authors:  Alejandro Hernández; Kushal Lakhani; Jorge H Núñez; Iñaki Mimendia; Aleix Pons; Víctor Barro
Journal:  J Clin Orthop Trauma       Date:  2021-08-08

2.  Lewinnek Safe Zone References are Frequently Misquoted.

Authors:  Aonnicha Burapachaisri; Ameer Elbuluk; Edem Abotsi; Jim Pierrepont; Seth A Jerabek; Aaron J Buckland; Jonathan M Vigdorchik
Journal:  Arthroplast Today       Date:  2020-11-26

3.  Comparison of cementless and cemented cups in revision total hip arthroplasty using a computed tomography-based navigation system.

Authors:  Hiroaki Tagomori; Nobuhiro Kaku; Tomonori Tabata; Yuta Kubota; Hiroshi Tsumura
Journal:  J Clin Orthop Trauma       Date:  2019-05-28

4.  The Evolution of Computer-Assisted Total Hip Arthroplasty and Relevant Applications.

Authors:  Jun-Dong Chang; In-Sung Kim; Atul M Bhardwaj; Ramachandra N Badami
Journal:  Hip Pelvis       Date:  2017-03-06

5.  Preservation of the Acetabular Cup During Revision Total Hip Arthroplasty Using a Novel Mini-navigation Tool: A Case Report.

Authors:  John Vincent; Ibrahim Alshaygy; Jeffrey M Muir; Paul Kuzyk
Journal:  J Orthop Case Rep       Date:  2018 Jan-Feb

6.  Clinical efficacy of orthopilot navigation system versus conventional manual of total hip arthroplasty: A systematic review and meta-analysis.

Authors:  Jianguo Jia; Qun Zhao; Pei Lu; Guiyong Fan; Hao Chen; Chaoqun Liu; Jinlian Liu; Sheng Chen; Zhengshuai Jin
Journal:  Medicine (Baltimore)       Date:  2019-05       Impact factor: 1.817

7.  Efficacy of Computed Tomography-Based Navigation for Cup Placement in Revision Total Hip Arthroplasty.

Authors:  Yuta Kubota; Nobuhiro Kaku; Tomonori Tabata; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  Clin Orthop Surg       Date:  2019-02-18

8.  Revision Total Hip Arthroplasty with Severe Acetabular Defect: A Preliminary Exploration and Attempt of Robotic-Assisted Technology.

Authors:  Shuai Zhang; Yu-Bo Liu; Ming-Yang Ma; Zheng Cao; Xiang-Peng Kong; Wei Chai
Journal:  Orthop Surg       Date:  2022-07-06       Impact factor: 2.279

9.  Three-dimensional technology assisted trabecular metal cup and augments positioning in revision total hip arthroplasty with complex acetabular defects.

Authors:  Qingtian Li; Xuepan Chen; Bofu Lin; Yuanchen Ma; Jun Xing Liao; Qiujian Zheng
Journal:  J Orthop Surg Res       Date:  2019-12-11       Impact factor: 2.359

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.