Literature DB >> 15188099

Modular revision for recurrent dislocation of primary or revision total hip arthroplasty.

Paul F Lachiewicz1, Elizabeth Soileau, John Ellis.   

Abstract

Two surgeons who used the same implants and surgical approach performed 23 revisions for recurrent dislocation of modular total hip arthroplasty (THA) with retention of components. For 17 primary hips, there was a mean of 3.8 (range, 2-10) dislocations before revision. Fifteen hips had exchange of the acetabular liner, 13 had a change in neck length, and 5 had a change in size of the femoral head. At a mean follow-up of 4 years (range, 2-7 years), 14 patients (82%) had no further dislocation, 1 had 1 additional dislocation, and 2 required additional surgery. For the 6 revision procedures, the mean number of dislocations was 3.8 (range, 2-10) before re-revision. Liner exchange was performed in 4 hips, neck length changed in 3 hips, and head size increased in 2 hips. At a mean follow-up of 3 years (range, 2-5 years), only 3 patients (50%) had no further dislocation, and 2 required additional surgery. Modular revision can be a successful method of treatment of recurrent dislocation after primary THA, but is much less successful after revision THA.

Entities:  

Mesh:

Year:  2004        PMID: 15188099     DOI: 10.1016/j.arth.2003.12.077

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  6 in total

Review 1.  [Is a dorsal access associated with an elevated luxation rate following total hip replacement?].

Authors:  F Kerschbaumer; G Kerschbaumer; F Deghani
Journal:  Orthopade       Date:  2007-10       Impact factor: 1.087

2.  Efficacy of revision surgery for the dislocating total hip arthroplasty: report from a large community registry.

Authors:  Tiare Salassa; Daniel Hoeffel; Susan Mehle; Penny Tatman; Terence J Gioe
Journal:  Clin Orthop Relat Res       Date:  2013-10-23       Impact factor: 4.176

3.  Isolated polyethylene exchange versus acetabular revision for polyethylene wear.

Authors:  Camilo Restrepo; Elie Ghanem; Carrie Houssock; Mathew Austin; Javad Parvizi; William J Hozack
Journal:  Clin Orthop Relat Res       Date:  2008-10-10       Impact factor: 4.176

4.  Comparison of cementless and cemented cups in revision total hip arthroplasty using a computed tomography-based navigation system.

Authors:  Hiroaki Tagomori; Nobuhiro Kaku; Tomonori Tabata; Yuta Kubota; Hiroshi Tsumura
Journal:  J Clin Orthop Trauma       Date:  2019-05-28

5.  Efficacy of Computed Tomography-Based Navigation for Cup Placement in Revision Total Hip Arthroplasty.

Authors:  Yuta Kubota; Nobuhiro Kaku; Tomonori Tabata; Hiroaki Tagomori; Hiroshi Tsumura
Journal:  Clin Orthop Surg       Date:  2019-02-18

Review 6.  Outcomes of dual modular cementless femoral stems in revision hip arthroplasty.

Authors:  Ali Ghoz; Matthew L Broadhead; John Morley; Shawn Tavares; David McDonald
Journal:  Orthop Rev (Pavia)       Date:  2014-03-31
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.