Forehead pulse oximetry compared with finger pulse oximetry and arterial blood gas measurement.

E Y Cheng1, M B Hopwood, J Kay.   

Abstract

Usual monitoring sites for pulse oximetry involve the fingers, toes, ear lobe, and nasal septum. This study examined the performance of a forehead sensor compared with a finger sensor for the pulse oximeter and arterial blood gas (ABG) analysis. Ten healthy adult volunteers and 22 ventilator-dependent patients were studied. The arterial oxygen saturation detected by forehead pulse oximetry (SpO2) correlated well with finger SpO2 and arterial oxygen saturation (SaO2) determined by arterial blood gas analysis in the healthy volunteers. Forehead SpO2 in mechanically ventilated patients correlated well with finger SpO2 and SaO2 when heart rate detected by pulse oximeter differed less than 10% from apical heart rate. Factors that caused a difference in oximeter-detected heart rate and apical heart rate were extensive tissue edema, head movement, and difficulty securing good tape placement. This suggests that when signal strength is weak, causing poor pulse rate detection, there will also be problems associated with accurate SpO2. The forehead pulse oximeter sensor works well on healthy, well-oxygenated volunteers. Difficulty was experienced when applying and using the sensor on critically ill patients. The reliability of the forehead pulse oximeter sensor has not been established at low saturations.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3210070     DOI: 10.1007/bf01621821

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  4 in total

1.  A light emitting diode skin reflectance oximeter.

Authors:  A Cohen; N Wadsworth
Journal:  Med Biol Eng       Date:  1972-05

2.  History of blood gas analysis. VI. Oximetry.

Authors:  J W Severinghaus; P B Astrup
Journal:  J Clin Monit       Date:  1986-10

3.  Spectrophotometric investigation of pulsatile blood flow for transcutaneous reflectance oximetry.

Authors:  Y Mendelson; P W Cheung; M R Neuman; D G Fleming; S D Cahn
Journal:  Adv Exp Med Biol       Date:  1983       Impact factor: 2.622

4.  Accuracy of response of six pulse oximeters to profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

  4 in total
  9 in total

1.  Reflection and transmission pulse oximetry during compromised peripheral perfusion.

Authors:  H Pälve
Journal:  J Clin Monit       Date:  1992-01

Review 2.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

3.  Reflectance pulse oximetry at the forehead improves by pressure on the probe.

Authors:  A C Dassel; R Graaff; M Sikkema; A Meijer; W G Zijlstra; J G Aarnoudse
Journal:  J Clin Monit       Date:  1995-07

4.  The effect of pulsating arteries on reflectance pulse oximetry: measurements in adults and neonates.

Authors:  R Nijland; H W Jongsma; P P van den Berg; J G Nijhuis; B Oeseburg
Journal:  J Clin Monit       Date:  1995-03

5.  A comparison of finger and forehead pulse oximeters in heart failure patients during maximal exercise.

Authors:  Kevin L Kelly; Alex R Carlson; Thomas G Allison; Bruce D Johnson
Journal:  Heart Lung       Date:  2019-11-14       Impact factor: 2.210

6.  Evaluation of the robustness of cerebral oximetry to variations in skin pigmentation using a tissue-simulating phantom.

Authors:  Ali Afshari; Rolf B Saager; David Burgos; William C Vogt; Jianting Wang; Gonzalo Mendoza; Sandy Weininger; Kung-Bin Sung; Anthony J Durkin; T Joshua Pfefer
Journal:  Biomed Opt Express       Date:  2022-04-21       Impact factor: 3.562

7.  Forehead reflectance oximetry: a clinical comparison with conventional digit sensors during laparotomic and laparoscopic abdominal surgery.

Authors:  Andrea Casati; Grazia Squicciarini; Marco Baciarello; Marta Putzu; Alessandra Salvadori; Guido Fanelli
Journal:  J Clin Monit Comput       Date:  2007-08-16       Impact factor: 2.502

8.  Intraoperative reflectance oximetry in burn patients.

Authors:  R L Sheridan; K M Prelack; L M Petras; S K Szyfelbein; R G Tompkins
Journal:  J Clin Monit       Date:  1995-01

9.  Accuracy of pulse oximetry in detection of oxygen saturation in patients admitted to the intensive care unit of heart surgery: comparison of finger, toe, forehead and earlobe probes.

Authors:  Sohila Seifi; Alireza Khatony; Gholamreza Moradi; Alireza Abdi; Farid Najafi
Journal:  BMC Nurs       Date:  2018-04-17
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.