Reflection and transmission pulse oximetry during compromised peripheral perfusion.

H Pälve1.   

Abstract

The performance of a reflection pulse oximeter and a transmission pulse oximeter was assessed during open-heart surgery when cardiac output, peripheral temperature, pulse pressure, and systolic pressure were low and vascular resistance was high. Before and after extracorporeal circulation (ECC) there was no difference in ability of the sensors to obtain readings and no difference in the accuracy of those readings. During partial ECC, especially after coronary artery bypass grafting, the reflection sensor gave readings earlier and at a lower pulse pressure. In addition, the transmission sensor failed to give any readings for 2 patients on partial ECC, for whom the reflection sensor did give readings. The accuracy of heart rate (HR) data was comparable for both sensors before ECC; however, during partial ECC, the reflection sensor tended to give values closer to the electrocardiographic HR. The accuracy of saturation data given by the reflection oximeter was comparable to that of the transmission oximeter. It is concluded that the accuracy of the saturation and HR data provided by the two methods of pulse oximetry are comparable, but that the reflection sensor is more likely to obtain readings under conditions of poorer peripheral circulation.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 1538246     DOI: 10.1007/bf01618081

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  18 in total

Review 1.  Principles of pulse oximetry: theoretical and practical considerations.

Authors:  C M Alexander; L E Teller; J B Gross
Journal:  Anesth Analg       Date:  1989-03       Impact factor: 5.108

2.  Discrepancy between finger and nasal pulse oximetry.

Authors:  J Rosenberg; M H Pedersen; J B Dahl
Journal:  Crit Care Med       Date:  1990-05       Impact factor: 7.598

3.  Design and evaluation of a new reflectance pulse oximeter sensor.

Authors:  Y Mendelson; J C Kent; B L Yocum; M J Birle
Journal:  Med Instrum       Date:  1988-08

4.  Forehead pulse oximetry compared with finger pulse oximetry and arterial blood gas measurement.

Authors:  E Y Cheng; M B Hopwood; J Kay
Journal:  J Clin Monit       Date:  1988-07

5.  Evaluation of pulse oximetry.

Authors:  M Yelderman; W New
Journal:  Anesthesiology       Date:  1983-10       Impact factor: 7.892

6.  A comparison of two pulse oximeters. Assessment of accuracy at low arterial saturation in paediatric surgical patients.

Authors:  S A Ridley
Journal:  Anaesthesia       Date:  1988-02       Impact factor: 6.955

7.  A clinical evaluation of pulse oximetry during thoracic surgery.

Authors:  D P Desiderio; G Wong; N K Shah; J Liu; C J Loughlin; R F Bedford
Journal:  J Cardiothorac Anesth       Date:  1990-02

8.  Errors in 14 pulse oximeters during profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh; S O Koh
Journal:  J Clin Monit       Date:  1989-04

9.  Accuracy of response of six pulse oximeters to profound hypoxia.

Authors:  J W Severinghaus; K H Naifeh
Journal:  Anesthesiology       Date:  1987-10       Impact factor: 7.892

10.  Minimum pulse pressure and peripheral temperature needed for pulse oximetry during cardiac surgery with cardiopulmonary bypass.

Authors:  H Pälve; A Vuori
Journal:  J Cardiothorac Vasc Anesth       Date:  1991-08       Impact factor: 2.628

View more
  5 in total

1.  Effect of functional neuromuscular stimulation on postural related orthostatic stress in individuals with acute spinal cord injury.

Authors:  A S Elokda; D H Nielsen; R K Shields
Journal:  J Rehabil Res Dev       Date:  2000 Sep-Oct

2.  The influence of larger subcutaneous blood vessels on pulse oximetry.

Authors:  Paul D Mannheimer; Neil Michael P O'; Ewald Konecny
Journal:  J Clin Monit Comput       Date:  2004-06       Impact factor: 2.502

3.  Pulse oximetry and high-dose vasopressors: a comparison between forehead reflectance and finger transmission sensors.

Authors:  Nicolas Nesseler; Jean-Vincent Frénel; Yoann Launey; Jeff Morcet; Yannick Mallédant; Philippe Seguin
Journal:  Intensive Care Med       Date:  2012-08-07       Impact factor: 17.440

4.  Reflectance pulse oximetry at the forehead improves by pressure on the probe.

Authors:  A C Dassel; R Graaff; M Sikkema; A Meijer; W G Zijlstra; J G Aarnoudse
Journal:  J Clin Monit       Date:  1995-07

5.  In vivo investigation of ear canal pulse oximetry during hypothermia.

Authors:  K Budidha; P A Kyriacou
Journal:  J Clin Monit Comput       Date:  2017-01-27       Impact factor: 2.502

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.