Literature DB >> 3537215

History of blood gas analysis. VI. Oximetry.

J W Severinghaus, P B Astrup.   

Abstract

Oximetry, the measurement of hemoglobin oxygen saturation in either blood or tissue, depends on the Lambert-Beer relationship between light transmission and optical density. Shortly after Bunsen and Kirchhoff invented the spectrometer in 1860, the oxygen transport function of hemoglobin was demonstrated by Stokes and Hoppe-Seyler, who showed color changes produced by aeration of hemoglobin solutions. In 1932 in Göttingen, Germany, Nicolai optically recorded the in vivo oxygen consumption of a hand after circulatory occlusion. Kramer showed that the Lambert-Beer law applied to hemoglobin solutions and approximately to whole blood, and measured saturation by the transmission of red light through unopened arteries. Matthes in Leipzig, Germany, built the first apparatus to measure ear oxygen saturation and introduced a second wavelength (green or infrared) insensitive to saturation to compensate for blood volume and tissue pigments. Millikan built a light-weight ear "oximeter" during World War II to train pilots for military aviation. Wood added a pneumatic cuff to obtain a bloodless zero. Brinkman and Zijlstra in Groningen, The Netherlands, showed that red light reflected from the forehead could be used to measure oxygen saturation. Zijlstra initiated cuvette and catheter reflection oximetry. Instrumentation Laboratory used multiple wavelengths to measure blood carboxyhemoglobin and methemoglobin is cuvette oximeters. Shaw devised an eight-wavelength ear oximeter. Nakajima and co-workers invented the pulse oximeter, which avoids the need for calibration with only two wavelengths by responding only to the pulsatile changes in transmitted red and infrared light. Lübbers developed catheter tip and cuvette fiberoptic sensors for oxygen tension, carbon dioxide tension, and pH.

Entities:  

Mesh:

Year:  1986        PMID: 3537215     DOI: 10.1007/BF02851177

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  62 in total

1.  The monitoring and recording of physiologic variables during closure of ventricular septal defects using extracorporeal circulation.

Authors:  E H WOOD; W F SUTTERER; D E DONALD
Journal:  Fortschr Kardiol       Date:  1959

2.  A photo-electric oxyhemograph; a continuous method for measuring the oxygen saturation of the blood.

Authors:  F W HARTMAN; V G BEHRMANN; F W CHAPMAN
Journal:  Am J Clin Pathol       Date:  1948-01       Impact factor: 2.493

3.  Continuous measurement of oxygen saturation in sick newborn infants.

Authors:  A R Wilkinson; R H Phibbs; G A Gregory
Journal:  J Pediatr       Date:  1978-12       Impact factor: 4.406

4.  In vivo monitoring with a fiber optic catheter.

Authors:  J B Taylor; B Lown; M Polanyi
Journal:  JAMA       Date:  1972-08-14       Impact factor: 56.272

5.  A solid state fiberoptics oximeter.

Authors:  C C Johnson; R D Palm; D C Stewart; W E Martin
Journal:  J Assoc Adv Med Instrum       Date:  1971 Mar-Apr

6.  Spectrophotometric determination of oxygen saturation of hemoglobin in the presence of carboxyhemoglobin.

Authors:  J Bjure; N J Nilsson
Journal:  Scand J Clin Lab Invest       Date:  1965       Impact factor: 1.713

7.  Pulse oximetry during pulmonary artery surgery.

Authors:  R H Friesen
Journal:  Anesth Analg       Date:  1985-03       Impact factor: 5.108

8.  Effects of multiple scattering and peripheral circulation on arterial oxygen saturation measured with a pulse-type oximeter.

Authors:  Y Shimada; I Yoshiya; N Oka; K Hamaguri
Journal:  Med Biol Eng Comput       Date:  1984-09       Impact factor: 2.602

9.  Photometric determination of oxyhemoglobin saturation in the presence of carbon monoxide hemoglobin, especially at low oxygen tensions.

Authors:  P Hellung-Larsen; K Kjeldsen; K Mellemgaard; P Astrup
Journal:  Scand J Clin Lab Invest       Date:  1966       Impact factor: 1.713

10.  [Non-invasive determination of oxygen saturation with the oxygenmet pulse wave oximeter on fingers, metacarpus and wrist of infants. Comparison with the oxygen saturation calculated from the pH and pO2 of the blood gas analysis (author's transl)].

Authors:  N Liappis
Journal:  Klin Padiatr       Date:  1979-09       Impact factor: 1.349

View more
  19 in total

1.  Reflectance pulse oximetry--principles and obstetric application in the Zurich system.

Authors:  V König; R Huch; A Huch
Journal:  J Clin Monit Comput       Date:  1998-08       Impact factor: 2.502

Review 2.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

3.  A spatial and temporal comparison of hemodynamic signals measured using optical and functional magnetic resonance imaging during activation in the human primary visual cortex.

Authors:  Vladislav Y Toronov; Xiaofeng Zhang; Andrew G Webb
Journal:  Neuroimage       Date:  2006-11-28       Impact factor: 6.556

4.  Evaluation of a pulse oximeter sensor tester.

Authors:  Shuba Dugani; Iljaz Hodzovic; Seema Sindhakar; Aida Nadra; Clare Dunstan; Anthony Richard Wilkes; John Mecklenburgh
Journal:  J Clin Monit Comput       Date:  2011-05-18       Impact factor: 2.502

5.  Comparison of invasive and noninvasive blood hemoglobin measurement in the operating room: a systematic review and meta-analysis.

Authors:  Hosein Shabaninejad; Nashmil Ghadimi; Kourosh Sayehmiri; Hossein Hosseinifard; Rasoul Azarfarin; Hasan Abolghasem Gorji
Journal:  J Anesth       Date:  2019-03-20       Impact factor: 2.078

6.  History of blood gas analysis. VII. Pulse oximetry.

Authors:  J W Severinghaus; Y Honda
Journal:  J Clin Monit       Date:  1987-04

7.  Welcome the new era of oximetry.

Authors:  R J Fallat
Journal:  Intensive Care Med       Date:  1988       Impact factor: 17.440

8.  Forehead pulse oximetry compared with finger pulse oximetry and arterial blood gas measurement.

Authors:  E Y Cheng; M B Hopwood; J Kay
Journal:  J Clin Monit       Date:  1988-07

Review 9.  Pulse oximetry: a review with emphasis on applications in dentistry.

Authors:  W W Schratz
Journal:  Anesth Prog       Date:  1987 May-Jun

Review 10.  Theory, instrumentation, and applications of electron paramagnetic resonance oximetry.

Authors:  Rizwan Ahmad; Periannan Kuppusamy
Journal:  Chem Rev       Date:  2010-05-12       Impact factor: 60.622

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.