| Literature DB >> 32040496 |
T D Do1, J Heim1, C Melzig1, D F Vollherbst2, H U Kauczor1, S Skornitzke1, C M Sommer1,3.
Abstract
OBJECTIVES: To compare image quality and metal artifact reduction between virtual monochromatic spectral imaging (VMSI), linearly blended dual-energy (DE) and single-energy (SE) images, each with and without dedicated iterative metal artifact reduction (iMAR) for CT-guided biopsy.Entities:
Mesh:
Year: 2020 PMID: 32040496 PMCID: PMC7010258 DOI: 10.1371/journal.pone.0228578
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Crosstable for p-values based on HU measurements at the trocar tip and liver parenchyma adjacent to the trocar tip, SNR and noise on axial images with VMSI, SE I30-3 and DE Q30-3 without iMAR.
| SE non-iMAR | DE (M0.5) non-iMAR | |||||||
|---|---|---|---|---|---|---|---|---|
| Trocar tip | Liver parenchyma adjacent to the trocar tip | SNR | Noise | Trocar tip | Liver parenchyma adjacent to the trocar tip | SNR | Noise | |
| p<0.01 | p<0.01 | p<0.05 | p<0.05 | p<0.01 | p<0.01 | x | x | |
| x | x | p<0.01 | p<0.05 | x | x | x | x | |
| x | x | x | x | x | x | x | x | |
| x | x | x | x | x | x | x | x | |
| x | x | x | x | x | x | x | x | |
| x | x | x | x | x | x | x | x | |
| x | x | x | x | x | x | x | x | |
| x | x | p<0.0001 | p<0.0001 | x | x | p<0.01 | p<0.01 | |
| x | x | x | x | -- | -- | -- | -- | |
Crosstable for p-values based on HU measurements at the trocar tip and liver parenchyma adjacent to the trocar tip, SNR and noise on axial images with VMSI, SE I30-3 and Q 30–3 with iMAR.
| SE iMAR | DE (M0.5) iMAR | |||||||
|---|---|---|---|---|---|---|---|---|
| Trocar tip | Liver parenchyma adjacent to the trocar tip | SNR | Noise | Trocar tip | Liver parenchyma adjacent to the trocar tip | SNR | Noise | |
| p<0.01 | p<0.05 | p<0.05 | p<0.05 | p<0.05 | x | x | x | |
| x | x | x | x | x | x | x | x | |
| x | x | x | x | x | x | x | x | |
| x | x | x | x | x | x | x | x | |
| x | x | x | x | x | x | x | x | |
| x | x | x | x | x | x | x | x | |
| x | x | x | x | x | x | x | ||
| x | x | p<0.001 | p<0.001 | x | x | p<0.01 | p<0.01 | |
| x | x | x | x | -- | -- | -- | -- | |
Results of threshold based semi-automated segmentation, given as a percentage of the liver.
| non-iMAR | iMAR | p-value | |
|---|---|---|---|
| 0.25 (0.21; 0.28) | 0.26 (0.23; 0.32) | 0.1562 | |
| 0.33 (0.27; 0.49) | 0.24 (0.17; 0.38) | ||
| 0.81 (0.77; 0.88) | 0.78 (0.71; 0.82) | ||
| 0.43 (0.3; 14) | 0.27 (0.22; 0.44) | ||
| 0.26 (0.23; 0.44) | 0.21 (0.19; 0.39) | ||
Dunn’s test for multiple comparisons
1: I30-3 13.5 mGy vs. 40 keV: p = 0.0191
Q30-3 13.5 mGy vs. 180 keV: p = 0.0349
40 keV vs. 180 keV: p = 0.0013
2: I30-3 13.5 mGy iMAR vs. 40 keV iMAR: p = 0.0191
40 keV iMAR vs. 80 keV iMar: p = 0.0052