Literature DB >> 26251433

CT Metal Artifact Reduction in the Spine: Can an Iterative Reconstruction Technique Improve Visualization?

A L Kotsenas1, G J Michalak2, D R DeLone2, F E Diehn2, K Grant3, A F Halaweish3, A Krauss4, R Raupach4, B Schmidt4, C H McCollough2, J G Fletcher2.   

Abstract

BACKGROUND AND
PURPOSE: Metal-related artifacts from spine instrumentation can obscure relevant anatomy and pathology. We evaluated the ability of CT images reconstructed with and without iterative metal artifact reduction to visualize critical anatomic structures in postoperative spines and assessed the potential for implementation into clinical practice.
MATERIALS AND METHODS: We archived CT projection data in patients with instrumented spinal fusion. CT images were reconstructed by using weighted filtered back-projection and iterative metal artifact reduction. Two neuroradiologists evaluated images in the region of spinal hardware and assigned a score for the visualization of critical anatomic structures by using soft-tissue and bone windows (critical structures totally obscured, n = 0; anatomic recognition with high diagnostic confidence, n = 5). Using bone windows, we measured the length of the most pronounced linear artifacts. For each patient, neuroradiologists made recommendations regarding the optimal use of iterative metal artifact reduction and its impact on diagnostic confidence.
RESULTS: Sixty-eight patients met the inclusion criteria. Visualization of critical soft-tissue anatomic structures was significantly improved by using iterative metal artifact reduction compared with weighted filtered back-projection (median, 1 ± 1.5 versus 3 ± 1.3, P < .001), with improvement in the worst visualized anatomic structure in 88% (60/68) of patients. There was not significant improvement in visualization of critical osseous structures. Linear metal artifacts were reduced from 29 to 11 mm (P < .001). In 87% of patients, neuroradiologists recommended reconstructing iterative metal artifact reduction images instead of weighted filtered back-projection images, with definite improvement in diagnostic confidence in 32% (22/68).
CONCLUSIONS: Iterative metal artifact reduction improves visualization of critical soft-tissue structures in patients with spinal hardware. Routine generation of these images in addition to routine weighted filtered back-projection is recommended.
© 2015 by American Journal of Neuroradiology.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 26251433      PMCID: PMC7964881          DOI: 10.3174/ajnr.A4416

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  16 in total

Review 1.  Iterative reconstruction methods in X-ray CT.

Authors:  Marcel Beister; Daniel Kolditz; Willi A Kalender
Journal:  Phys Med       Date:  2012-02-10       Impact factor: 2.685

2.  Frequency split metal artifact reduction (FSMAR) in computed tomography.

Authors:  Esther Meyer; Rainer Raupach; Michael Lell; Bernhard Schmidt; Marc Kachelrieß
Journal:  Med Phys       Date:  2012-04       Impact factor: 4.071

3.  Metallic artefact reduction with monoenergetic dual-energy CT: systematic ex vivo evaluation of posterior spinal fusion implants from various vendors and different spine levels.

Authors:  R Guggenberger; S Winklhofer; G Osterhoff; G A Wanner; M Fortunati; G Andreisek; H Alkadhi; P Stolzmann
Journal:  Eur Radiol       Date:  2012-05-30       Impact factor: 5.315

4.  Frequency split metal artefact reduction in pelvic computed tomography.

Authors:  M M Lell; E Meyer; M Schmid; R Raupach; M S May; M Uder; M Kachelriess
Journal:  Eur Radiol       Date:  2013-03-22       Impact factor: 5.315

Review 5.  Technical considerations: CT and MR imaging in the postoperative orthopedic patient.

Authors:  Lawrence M White; Kenneth A Buckwalter
Journal:  Semin Musculoskelet Radiol       Date:  2002-03       Impact factor: 1.777

Review 6.  Failed back surgery syndrome.

Authors:  Chin-wern Chan; Philip Peng
Journal:  Pain Med       Date:  2011-04-04       Impact factor: 3.750

7.  Metal artifact reduction by dual-energy computed tomography using energetic extrapolation: a systematically optimized protocol.

Authors:  Felix G Meinel; Bernhard Bischoff; Qiaowei Zhang; Fabian Bamberg; Maximilian F Reiser; Thorsten R C Johnson
Journal:  Invest Radiol       Date:  2012-07       Impact factor: 6.016

8.  Metal artefact reduction from dental hardware in carotid CT angiography using iterative reconstructions.

Authors:  Fabian Morsbach; Moritz Wurnig; Daniel M Kunz; Andreas Krauss; Bernhard Schmidt; Spyros S Kollias; Hatem Alkadhi
Journal:  Eur Radiol       Date:  2013-05-19       Impact factor: 5.315

Review 9.  Metal-related artifacts in instrumented spine. Techniques for reducing artifacts in CT and MRI: state of the art.

Authors:  P Stradiotti; A Curti; G Castellazzi; A Zerbi
Journal:  Eur Spine J       Date:  2009-05-13       Impact factor: 3.134

10.  A new algorithm for metal artifact reduction in computed tomography: in vitro and in vivo evaluation after total hip replacement.

Authors:  Andreas H Mahnken; Rainer Raupach; Joachim E Wildberger; Bettina Jung; Nicole Heussen; Thomas G Flohr; Rolf W Günther; Stefan Schaller
Journal:  Invest Radiol       Date:  2003-12       Impact factor: 6.016

View more
  17 in total

1.  Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

Authors:  Wei Zhou; David J Bartlett; Felix E Diehn; Katrina N Glazebrook; Amy L Kotsenas; Rickey E Carter; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  Invest Radiol       Date:  2019-04       Impact factor: 6.016

2.  Iterative algorithms for metal artifact reduction in children with orthopedic prostheses: preliminary results.

Authors:  Seema Toso; Meryle Laurent; Elise Dupuis Lozeron; Pauline Brindel; Marirosa Cristallo Lacalamita; Sylviane Hanquinet
Journal:  Pediatr Radiol       Date:  2018-07-28

3.  Automatic tube current modulation for whole-body polytrauma CT with immobilization devices: is there an increase in radiation dose and degradation of image quality?

Authors:  André Euler; Bram Stieltjes; Sebastian T Schindera
Journal:  Emerg Radiol       Date:  2016-09-10

4.  Iterative metal artefact reduction (MAR) in postsurgical chest CT: comparison of three iMAR-algorithms.

Authors:  Joel Aissa; Johannes Boos; Lino Morris Sawicki; Niklas Heinzler; Karl Krzymyk; Martin Sedlmair; Patric Kröpil; Gerald Antoch; Christoph Thomas
Journal:  Br J Radiol       Date:  2017-08-22       Impact factor: 3.039

Review 5.  Unintended Consequences: Review of New Artifacts Introduced by Iterative Reconstruction CT Metal Artifact Reduction in Spine Imaging.

Authors:  D R Wayer; N Y Kim; B J Otto; A M Grayev; A D Kuner
Journal:  AJNR Am J Neuroradiol       Date:  2019-10-03       Impact factor: 3.825

6.  Clinical evaluation of the iterative metal artefact reduction algorithm for post-operative CT examination after maxillofacial surgery.

Authors:  Arsany Hakim; Johannes Slotboom; Olivier Lieger; Fabian Schlittler; Roland Giger; Chantal Michel; Roland Wiest; Franca Wagner
Journal:  Dentomaxillofac Radiol       Date:  2017-03-07       Impact factor: 2.419

7.  The current role and future directions of imaging in failed back surgery syndrome patients: an educational review.

Authors:  Richard L Witkam; Constantinus F Buckens; Johan W M van Goethem; Kris C P Vissers; Dylan J H A Henssen
Journal:  Insights Imaging       Date:  2022-07-15

Review 8.  [Iterative algorithms for artifact reduction in computed tomography].

Authors:  S Skornitzke
Journal:  Radiologe       Date:  2018-03       Impact factor: 0.635

9.  Utility of an automatic adaptive iterative metal artifact reduction AiMAR algorithm in improving CT imaging of patients with hip prostheses evaluated for suspected bladder malignancy.

Authors:  Payam Mohammadinejad; Ashish Khandelwal; Akitoshi Inoue; Hiroaki Takahashi; Mariana Yalon; Zaiyang Long; Ahmed F Halaweish; Shuai Leng; Lifeng Yu; Yong S Lee; Cynthia H McCollough; Joel G Fletcher
Journal:  Abdom Radiol (NY)       Date:  2022-03-23

10.  CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection.

Authors:  Felix E Diehn; Gregory J Michalak; David R DeLone; Amy L Kotsenas; E Paul Lindell; Norbert G Campeau; Ahmed F Halaweish; Cynthia H McCollough; Joel G Fletcher
Journal:  Acta Radiol Open       Date:  2017-11-26
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.