Noise and Bias Properties of Monoenergetic Images from DECT used for Attenuation Correction with PET/CT and SPECT/CT.

Ting Xia1, Adam M Alessio, Paul E Kinahan.   

Abstract

We evaluate the energy dependent noise and bias properties of monoenergetic images synthesized from dual-energy CT (DECT) acquisitions used to estimate attenuation coefficients at PET or SPECT energies. This is becoming more relevant with the increased used of quantitative imaging by PET/CT and SPECT/CT. There are, however, variations in the noise and bias properties of synthesized monoenergetic images as a function of energy. We used analytic approximations and simulations to estimate the bias and noise of synthesized monoenergetic images of a water-filled cylinder from 10 to 525 keV. The dual-energy spectra were based on the GE Lightspeed VCT scanner at 80 and 140 kVp. Both analytic calculations and simulations for increasing energy the relative noise plateaued near 140 keV (i.e. SPECT with (99m)Tc), and then remained constant with increasing energy up to 511 keV and beyond (i.e. PET). If DECT is being used for attenuation correction at higher energies, there is a noise amplification that is dependent on the energy of the synthesized monoenergetic image of linear attenuation coefficients. For SPECT and PET imaging the bias and noise levels of DECT based attenuation correction is unlikely to affect image quality.

Entities:  

Year:  2010        PMID: 20607099      PMCID: PMC2895934          DOI: 10.1117/12.844075

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  7 in total

Review 1.  X-ray-based attenuation correction for positron emission tomography/computed tomography scanners.

Authors:  Paul E Kinahan; Bruce H Hasegawa; Thomas Beyer
Journal:  Semin Nucl Med       Date:  2003-07       Impact factor: 4.446

2.  Attenuation correction for a combined 3D PET/CT scanner.

Authors:  P E Kinahan; D W Townsend; T Beyer; D Sashin
Journal:  Med Phys       Date:  1998-10       Impact factor: 4.071

3.  Energy-selective reconstructions in X-ray computerized tomography.

Authors:  R E Alvarez; A Macovski
Journal:  Phys Med Biol       Date:  1976-09       Impact factor: 3.609

4.  Generalized image combinations in dual KVP digital radiography.

Authors:  L A Lehmann; R E Alvarez; A Macovski; W R Brody; N J Pelc; S J Riederer; A L Hall
Journal:  Med Phys       Date:  1981 Sep-Oct       Impact factor: 4.071

5.  A combined PET/CT scanner for clinical oncology.

Authors:  T Beyer; D W Townsend; T Brun; P E Kinahan; M Charron; R Roddy; J Jerin; J Young; L Byars; R Nutt
Journal:  J Nucl Med       Date:  2000-08       Impact factor: 10.057

6.  Dual energy CT attenuation correction methods for quantitative assessment of response to cancer therapy with PET/CT imaging.

Authors:  Paul E Kinahan; Adam M Alessio; Jeffery A Fessler
Journal:  Technol Cancer Res Treat       Date:  2006-08

7.  Statistical sinogram restoration in dual-energy CT for PET attenuation correction.

Authors:  Joonki Noh; Jeffrey A Fessler; Paul E Kinahan
Journal:  IEEE Trans Med Imaging       Date:  2009-03-24       Impact factor: 10.048

  7 in total
  3 in total

1.  Dual energy CT for attenuation correction with PET/CT.

Authors:  Ting Xia; Adam M Alessio; Paul E Kinahan
Journal:  Med Phys       Date:  2014-01       Impact factor: 4.071

2.  Dual-energy CT imaging of nasopharyngeal cancer cells using multifunctional gold nanoparticles.

Authors:  Sara Khademi; Saeed Sarkar; Ali Shakeri-Zadeh; Neda Attaran; Sharmin Kharrazi; Razieh Solgi; Mohammad Reza Ay; Hosein Azimian; Hossein Ghadiri
Journal:  IET Nanobiotechnol       Date:  2019-12       Impact factor: 1.847

3.  Virtual monochromatic spectral imaging versus linearly blended dual-energy and single-energy imaging during CT-guided biopsy needle positioning: Optimization of keV settings and impact on image quality.

Authors:  T D Do; J Heim; C Melzig; D F Vollherbst; H U Kauczor; S Skornitzke; C M Sommer
Journal:  PLoS One       Date:  2020-02-10       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.