Literature DB >> 23479714

Virtual monochromatic spectral imaging with fast kilovoltage switching: reduction of metal artifacts at CT.

Eric Pessis1, Raphaël Campagna, Jean-Michel Sverzut, Fabienne Bach, Mathieu Rodallec, Henri Guerini, Antoine Feydy, Jean-Luc Drapé.   

Abstract

With arthroplasty being increasingly used to relieve joint pain, imaging of patients with metal implants can represent a significant part of the clinical work load in the radiologist's daily practice. Computed tomography (CT) plays an important role in the postoperative evaluation of patients who are suspected of having metal prosthesis-related problems such as aseptic loosening, bone resorption or osteolysis, infection, dislocation, metal hardware failure, or periprosthetic bone fracture. Despite advances in detector technology and computer software, artifacts from metal implants can seriously degrade the quality of CT images, sometimes to the point of making them diagnostically unusable. Several factors may help reduce the number and severity of artifacts at multidetector CT, including decreasing the detector collimation and pitch, increasing the kilovolt peak and tube charge, and using appropriate reconstruction algorithms and section thickness. More recently, dual-energy CT has been proposed as a means of reducing beam-hardening artifacts. The use of dual-energy CT scanners allows the synthesis of virtual monochromatic spectral (VMS) images. Monochromatic images depict how the imaged object would look if the x-ray source produced x-ray photons at only a single energy level. For this reason, VMS imaging is expected to provide improved image quality by reducing beam-hardening artifacts.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23479714     DOI: 10.1148/rg.332125124

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  52 in total

1.  Reduction of metallic coil artefacts in computed tomography body imaging: effects of a new single-energy metal artefact reduction algorithm.

Authors:  Masafumi Kidoh; Daisuke Utsunomiya; Osamu Ikeda; Yoshitaka Tamura; Seitaro Oda; Yoshinori Funama; Hideaki Yuki; Takeshi Nakaura; Takayuki Kawano; Toshinori Hirai; Yasuyuki Yamashita
Journal:  Eur Radiol       Date:  2015-08-14       Impact factor: 5.315

Review 2.  Imaging near orthopedic hardware.

Authors:  Matthew F Koff; Alissa J Burge; Kevin M Koch; Hollis G Potter
Journal:  J Magn Reson Imaging       Date:  2017-02-02       Impact factor: 4.813

3.  Differentiating malignant vertebral tumours from non-malignancies with CT spectral imaging: a preliminary study.

Authors:  Yuan Yuan; Yan Zhang; Ning Lang; Jianying Li; Huishu Yuan
Journal:  Eur Radiol       Date:  2015-05-23       Impact factor: 5.315

4.  Metal artifact reduction using virtual monochromatic images for patients with pedicle screws implants on CT.

Authors:  Yue Dong; Ai Jun Shi; Jian Lin Wu; Ru Xin Wang; Li Fei Sun; Ai Lian Liu; Yi Jun Liu
Journal:  Eur Spine J       Date:  2015-06-13       Impact factor: 3.134

5.  Metal artefact reduction in CT imaging of hip prostheses—an evaluation of commercial techniques provided by four vendors.

Authors:  K M Andersson; P Nowik; J Persliden; P Thunberg; E Norrman
Journal:  Br J Radiol       Date:  2015-05-27       Impact factor: 3.039

6.  [Postoperative spine].

Authors:  R Schlaeger; J M Lieb; K Shariat; F J Ahlhelm
Journal:  Radiologe       Date:  2014-11       Impact factor: 0.635

7.  Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation.

Authors:  Yanwei Zeng; Kai Deng; Haitao Yang; Yi Tan; Jun Liu; Daoying Geng; Jun Zhang
Journal:  Eur Spine J       Date:  2019-04-30       Impact factor: 3.134

8.  Dual-layer spectral computerized tomography for metal artifact reduction: small versus large orthopedic devices.

Authors:  Christos Kosmas; Mojgan Hojjati; Peter C Young; Aidin Abedi; Ali Gholamrezanezhad; Prabhakar Rajiah
Journal:  Skeletal Radiol       Date:  2019-06-01       Impact factor: 2.199

Review 9.  Opportunities for new CT contrast agents to maximize the diagnostic potential of emerging spectral CT technologies.

Authors:  Benjamin M Yeh; Paul F FitzGerald; Peter M Edic; Jack W Lambert; Robert E Colborn; Michael E Marino; Paul M Evans; Jeannette C Roberts; Zhen J Wang; Margaret J Wong; Peter J Bonitatibus
Journal:  Adv Drug Deliv Rev       Date:  2016-09-09       Impact factor: 15.470

10.  Added value of a single-energy projection-based metal-artifact reduction algorithm for the computed tomography evaluation of oral cavity cancers.

Authors:  Kenichiro Hirata; Daisuke Utsunomiya; Seitaro Oda; Masafumi Kidoh; Yoshinori Funama; Hideaki Yuki; Morikatsu Yoshida; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2015-08-19       Impact factor: 2.374

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.