Literature DB >> 23513244

Reduction of metal artifacts from hip prostheses on CT images of the pelvis: value of iterative reconstructions.

Fabian Morsbach1, Sebastian Bickelhaupt, Guido A Wanner, Andreas Krauss, Bernhard Schmidt, Hatem Alkadhi.   

Abstract

PURPOSE: To assess the value of iterative frequency split-normalized (IFS) metal artifact reduction (MAR) for computed tomography (CT) of hip prostheses.
MATERIALS AND METHODS: This study had institutional review board and local ethics committee approval. First, a hip phantom with steel and titanium prostheses that had inlays of water, fat, and contrast media in the pelvis was used to optimize the IFS algorithm. Second, 41 consecutive patients with hip prostheses who were undergoing CT were included. Data sets were reconstructed with filtered back projection, the IFS algorithm, and a linear interpolation MAR algorithm. Two blinded, independent readers evaluated axial, coronal, and sagittal CT reformations for overall image quality, image quality of pelvic organs, and assessment of pelvic abnormalities. CT attenuation and image noise were measured. Statistical analysis included the Friedman test, Wilcoxon signed-rank test, and Levene test.
RESULTS: Ex vivo experiments demonstrated an optimized IFS algorithm by using a threshold of 2200 HU with four iterations for both steel and titanium prostheses. Measurements of CT attenuation of the inlays were significantly (P < .001) more accurate for IFS when compared with filtered back projection. In patients, best overall and pelvic organ image quality was found in all reformations with IFS (P < .001). Pelvic abnormalities in 11 of 41 patients (27%) were diagnosed with significantly (P = .002) higher confidence on the basis of IFS images. CT attenuation of bladder (P < .001) and muscle (P = .043) was significantly less variable with IFS compared with filtered back projection and linear interpolation MAR. In comparison with that of FBP and linear interpolation MAR, noise with IFS was similar close to and far from the prosthesis (P = .295).
CONCLUSION: The IFS algorithm for CT image reconstruction significantly reduces metal artifacts from hip prostheses, improves the reliability of CT number measurements, and improves the confidence for depicting pelvic abnormalities.

Entities:  

Mesh:

Substances:

Year:  2013        PMID: 23513244     DOI: 10.1148/radiol.13122089

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  50 in total

1.  [F-18]2-fluoro-2-deoxyglucose (FDG) positron emission tomography after limb salvage surgery: post-surgical appearance, attenuation correction and local complications.

Authors:  Michael J Gelfand; Susan E Sharp
Journal:  Pediatr Radiol       Date:  2015-02-27

2.  Improved Image Quality in Head and Neck CT Using a 3D Iterative Approach to Reduce Metal Artifact.

Authors:  W Wuest; M S May; M Brand; N Bayerl; A Krauss; M Uder; M Lell
Journal:  AJNR Am J Neuroradiol       Date:  2015-08-13       Impact factor: 3.825

Review 3.  Imaging near orthopedic hardware.

Authors:  Matthew F Koff; Alissa J Burge; Kevin M Koch; Hollis G Potter
Journal:  J Magn Reson Imaging       Date:  2017-02-02       Impact factor: 4.813

4.  Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

Authors:  Wei Zhou; David J Bartlett; Felix E Diehn; Katrina N Glazebrook; Amy L Kotsenas; Rickey E Carter; Joel G Fletcher; Cynthia H McCollough; Shuai Leng
Journal:  Invest Radiol       Date:  2019-04       Impact factor: 6.016

5.  Development and first validation of a simplified CT-based classification system of soft tissue changes in large-head metal-on-metal total hip replacement: intra- and interrater reliability and association with revision rates in a uniform cohort of 664 arthroplasties.

Authors:  Martijn F Boomsma; Mireille A Edens; Christiaan P Van Lingen; Niek Warringa; Harmen B Ettema; Cees C P M Verheyen; Mario Maas
Journal:  Skeletal Radiol       Date:  2015-05-06       Impact factor: 2.199

6.  Improved image quality in abdominal CT in patients who underwent treatment for hepatocellular carcinoma with small metal implants using a raw data-based metal artifact reduction algorithm.

Authors:  Keitaro Sofue; Takeshi Yoshikawa; Yoshiharu Ohno; Noriyuki Negi; Hiroyasu Inokawa; Naoki Sugihara; Kazuro Sugimura
Journal:  Eur Radiol       Date:  2016-12-02       Impact factor: 5.315

7.  Iterative algorithms for metal artifact reduction in children with orthopedic prostheses: preliminary results.

Authors:  Seema Toso; Meryle Laurent; Elise Dupuis Lozeron; Pauline Brindel; Marirosa Cristallo Lacalamita; Sylviane Hanquinet
Journal:  Pediatr Radiol       Date:  2018-07-28

8.  Single-energy metal artifact reduction for helical computed tomography of the pelvis in patients with metal hip prostheses.

Authors:  Koichiro Yasaka; Eriko Maeda; Shouhei Hanaoka; Masaki Katsura; Jiro Sato; Kuni Ohtomo
Journal:  Jpn J Radiol       Date:  2016-07-11       Impact factor: 2.374

9.  Validation of a Metal Artifact Reduction Algorithm Using 1D Linear Interpolation for Cone Beam CT after Endovascular Coiling Therapy for Cerebral Aneurysms.

Authors:  Mitsuyoshi Yasuda; Kohki Yoshikawa; Kyoichi Kato; Shogo Sai; Koshi Sakiyama; Yoshifumi Kobayashi; Miwa Oosawa; Hisaya Sato; Hiroaki Matsumoto; Yasuo Nakazawa
Journal:  Neuroradiol J       Date:  2014-12-01

10.  Independent value of image fusion in unenhanced breast MRI using diffusion-weighted and morphological T2-weighted images for lesion characterization in patients with recently detected BI-RADS 4/5 x-ray mammography findings.

Authors:  Sebastian Bickelhaupt; Jana Tesdorff; Frederik Bernd Laun; Tristan Anselm Kuder; Wolfgang Lederer; Susanne Teiner; Klaus Maier-Hein; Heidi Daniel; Anne Stieber; Stefan Delorme; Heinz-Peter Schlemmer
Journal:  Eur Radiol       Date:  2016-05-18       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.