Byeong Soo Kang1, Jin Wook Jeoung1, Joo Youn Oh2,3.
Abstract
BACKGROUND: To report three cases of congenital corneal opacity where intraocular pressure (IOP) readings were high despite the use of multiple anti-glaucoma eye drops and normalized after corneal transplantation. CASEEntities:
Keywords: Applanation-based tonometry; Case report; Congenital corneal opacity; Congenital glaucoma; Intraocular pressure
Mesh:
Substances:
Year: 2020 PMID: 31898507 PMCID: PMC6941358 DOI: 10.1186/s12886-019-1287-7
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Fig. 1Case 1. a, b Anterior segment photography of the right (a) and left (b) eyes taken at the initial visit to our clinic (7 months after birth). The intraocular pressure (IOP) values measured by a rebound tonometer were 42.5 mmHg OD and 45.1 mmHg OS. c Hematoxylin-eosin staining of the right cornea excised at the time of penetrating keratoplasty (PK). Scale bar, 200 μm. d Anterior segment photograph of the right eye 1 day after PK. The IOP by a rebound tonometer was 18.8 mmHg OD
Fig. 2Case 2. a, b Anterior segment photography of the right (a) and left eyes (b) 15 days after birth. The intraocular pressure (IOP) was 32.5 mmHg OD and 26.4 mmHg OS by rebound tonometer. c Anterior segment photograph of the left eye 2 days after penetrating keratoplasty (PK). IOP was reduced to 21.0 mmHg OS. d Anterior segment photograph of the left eye 18 months after surgery. The IOP was 17.5 mmHg without anti-glaucoma medication OS
Real time RT-PCR analysis of the cornea for extracellular matrix proteins
| Collage type 1 | Collagen type 5 | Luimcan | |
|---|---|---|---|
| Case 2 | 19.7a | 7.5 | 1.19 |
| Case 3 | 9.5 | 2.8 | 0.39 |
| Control 1b | 1 | 1 | 1 |
| Control 2b | 1.25 | 0.96 | 0.10 |
aData are presented as a fold change relative to control corneas
bControl corneas were obtained from patients with CHED at the time of penetrating keratoplasty (PK). PK was performed at 4 years of age in control 1 and 10 months in control 2
Fig. 3Case 3. a, b Anterior segment photography of the right (a) and left eyes (b) 3 months after birth. The intraocular pressure (IOP) values were 38.1 mmHg OD and 35.7 mmHg OS as measured by rebound tonometer. c Anterior segment photograph of the right eye 1 day after penetrating keratoplasty (PK). The IOP was 14.2 mmHg OD. d Anterior segment photograph of the right eye at the post-operative 4 months. The IOP by a rebound tonometer was 21.3 mmHg OD without medication