Literature DB >> 31312672

Back-irradiated and dual-screen sandwich detector configurations for radiography.

Anthony R Lubinsky1, Adrian Howansky1, Hao Zheng1, Wei Zhao1.   

Abstract

Recent advances in thin film transistor array technology have enabled the possibility of "back-irradiated" (BI) indirect active-matrix flat-panel imagers (AMFPIs), in which x-rays first expose the scintillator through the optical sensor, and "dual-screen" AMFPIs, in which two scintillating screens are sandwiched around a bidirectional active matrix. We developed a theoretical treatment of such detectors. The theory is used to investigate possible imaging performance improvements over conventional "front-irradiation" (FI) AMFPIs, where the active matrix is opposite the x-ray entrance surface. Simple expressions for the modulation transfer function, normalized noise power spectrum, Swank factor ( A s ), Lubberts function L ( f ) , and spatial frequency-dependent detective quantum efficiency DQE ( f ) are derived and used to compute these quantities for a variety of FI, BI, and dual-screen detector configurations. DQE ( f ) is used as the figure of merit for optimizing and comparing the performance of the various configurations. Large performance improvements over FI single-screen systems are found possible with BI. Further improvements are found possible with dual-screen configurations. The ratio of the thicknesses of the two screens that optimizes DQE is generally asymmetric, with the thinner screen facing the incident flux. The optimum ratio depends on the x-ray attenuation length in the screen.

Entities:  

Keywords:  Lubberts effect; Swank factor; detective quantum efficiency; digital radiography; flat-panel detector; indirect x-ray detection

Year:  2019        PMID: 31312672      PMCID: PMC6614698          DOI: 10.1117/1.JMI.6.3.033501

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  14 in total

1.  Screen film processing systems for medical radiography: a historical review.

Authors:  A G Haus; J E Cullinan
Journal:  Radiographics       Date:  1989-11       Impact factor: 5.333

2.  Lubberts effect in columnar phosphors.

Authors:  Aldo Badano; Robert M Gagne; Brandon D Gallas; Robert J Jennings; Jonathan S Boswell; Kyle J Myers
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

3.  Describing the signal-transfer characteristics of asymmetrical radiographic screen-film systems.

Authors:  R Van Metter
Journal:  Med Phys       Date:  1992 Jan-Feb       Impact factor: 4.071

4.  Screen optics effects on detective quantum efficiency in digital radiography: zero-frequency effects.

Authors:  A R Lubinsky; Wei Zhao; Goran Ristic; J A Rowlands
Journal:  Med Phys       Date:  2006-05       Impact factor: 4.071

5.  Calculation of modulation transfer functions of x-ray fluorescent screens.

Authors:  R K Swank
Journal:  Appl Opt       Date:  1973-08-01       Impact factor: 1.980

6.  An apparatus and method for directly measuring the depth-dependent gain and spatial resolution of turbid scintillators.

Authors:  Adrian Howansky; A R Lubinsky; Katsuhiko Suzuki; S Ghose; Wei Zhao
Journal:  Med Phys       Date:  2018-10-01       Impact factor: 4.071

7.  Effect of finite phosphor thickness on detective quantum efficiency.

Authors:  R M Nishikawa; M J Yaffe; R B Holmes
Journal:  Med Phys       Date:  1989 Sep-Oct       Impact factor: 4.071

8.  Deriving depth-dependent light escape efficiency and optical Swank factor from measured pulse height spectra of scintillators.

Authors:  Adrian Howansky; Boyu Peng; Anthony R Lubinsky; Wei Zhao
Journal:  Med Phys       Date:  2017-02-13       Impact factor: 4.071

9.  Fundamental x-ray interaction limits in diagnostic imaging detectors: frequency-dependent Swank noise.

Authors:  G Hajdok; J J Battista; I A Cunningham
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

10.  Characterization of a clinical unit for digital radiography based on irradiation side sampling technology.

Authors:  Stefano Rivetti; Nico Lanconelli; Marco Bertolini; Andrea Nitrosi; Aldo Burani
Journal:  Med Phys       Date:  2013-10       Impact factor: 4.071

View more
  3 in total

1.  Comparison of CsI:Tl and Gd2 O2 S:Tb indirect flat panel detector x-ray imaging performance in front- and back-irradiation geometries.

Authors:  Adrian Howansky; Anastasiia Mishchenko; A R Lubinsky; Wei Zhao
Journal:  Med Phys       Date:  2019-09-23       Impact factor: 4.071

2.  Evaluation of a hybrid direct-indirect active matrix flat-panel imager using Monte Carlo simulation.

Authors:  Scott Dow; Adrian Howansky; Anthony R Lubinsky; Wei Zhao
Journal:  J Med Imaging (Bellingham)       Date:  2020-05-12

3.  Analogous Lubberts effect in photon counting detectors.

Authors:  Ke Li
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-03-16