Literature DB >> 32546891

Analogous Lubberts effect in photon counting detectors.

Ke Li1,2.   

Abstract

For a light burst generated by an x ray-scintillator interaction, the quasi-isotropic spreading of optical quanta determines that both the light collection efficiency and the spread function of the light burst depend on the depth (z) of interaction: the closer the initial position of light burst to the light sensor, the less light loss and spatial resolution degradation a detector system encounters. For scintillator-based indirect-conversion detectors, the variation of the x-ray conversion gain and the MTF along the z direction contributes to a significant fraction of DQE loss and is known as the Lubberts effect. Understanding the physics behinds the effect and developing solutions to reduce the effect have led to tremendous improvements in the performance of indirect-conversion detectors. In contrast, for direct-conversion photon counting detectors (PCDs), since no optical quanta generation or transport is involved, there is no classical Lubberts effect. However, the transport properties of the generated charge carriers in semiconductors do depend on their travel distance. As a result, the performance of direct conversion detectors may depend on z. This dependence can be considered as a counterpart of the classical Lubberts effect. The purpose of this work is to analyze the contributions of a variety of physical mechanisms that may contribute to a Lubberts-like effect in direct-conversion PCDs. The results show that the Lubberts-like effect is primarily caused by the depth-dependent charge trapping and recombination likelihood. Based upon the physics analysis, PCD electrode design can be optimized to minimize the Lubberts-like effect and the associate DQE loss.

Entities:  

Keywords:  Lubberts effect; detective quantum efficiency; photon counting detector

Year:  2020        PMID: 32546891      PMCID: PMC7296710          DOI: 10.1117/12.2549785

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  6 in total

1.  Lubberts effect in columnar phosphors.

Authors:  Aldo Badano; Robert M Gagne; Brandon D Gallas; Robert J Jennings; Jonathan S Boswell; Kyle J Myers
Journal:  Med Phys       Date:  2004-11       Impact factor: 4.071

2.  Back-irradiated and dual-screen sandwich detector configurations for radiography.

Authors:  Anthony R Lubinsky; Adrian Howansky; Hao Zheng; Wei Zhao
Journal:  J Med Imaging (Bellingham)       Date:  2019-07-09

3.  Comparison of CsI:Tl and Gd2 O2 S:Tb indirect flat panel detector x-ray imaging performance in front- and back-irradiation geometries.

Authors:  Adrian Howansky; Anastasiia Mishchenko; A R Lubinsky; Wei Zhao
Journal:  Med Phys       Date:  2019-09-23       Impact factor: 4.071

4.  An apparatus and method for directly measuring the depth-dependent gain and spatial resolution of turbid scintillators.

Authors:  Adrian Howansky; A R Lubinsky; Katsuhiko Suzuki; S Ghose; Wei Zhao
Journal:  Med Phys       Date:  2018-10-01       Impact factor: 4.071

5.  Effect of finite phosphor thickness on detective quantum efficiency.

Authors:  R M Nishikawa; M J Yaffe; R B Holmes
Journal:  Med Phys       Date:  1989 Sep-Oct       Impact factor: 4.071

6.  Signal and noise characteristics of a CdTe-based photon counting detector: Cascaded systems analysis and experimental studies.

Authors:  Xu Ji; Ran Zhang; Yongshuai Ge; Guang-Hong Chen; Ke Li
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2017-03-09
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.