Evaluation of a hybrid direct-indirect active matrix flat-panel imager using Monte Carlo simulation.

Scott Dow1, Adrian Howansky1, Anthony R Lubinsky1, Wei Zhao1.   

Abstract

Purpose: Monte Carlo simulations were used to evaluate the imaging properties of a composite direct-indirect active matrix flat-panel imager (AMFPI) with potentially more favorable tradeoffs between x-ray quantum efficiency and spatial resolution than direct or indirect AMFPIs alone. This configuration, referred to as a hybrid AMFPI, comprises a scintillator that is optically coupled to an a-Se direct AMFPI through a transparent electrode and hole blocking layer, such that a-Se acts as both a direct x-ray converter and an optical sensor. Approach: GEANT4 was used to simulate x-ray energy deposition, optical transport, and charge signal generation processes in various hybrid AMPFI configurations under RQA5 and RQA9 x-ray beam conditions. The Fujita-Lubberts-Swank method was used to quantify the impact of irradiation geometry, x-ray converter thicknesses, conversion gain of each layer, and x-ray cross talk between layers on detective quantum efficiency (DQE).
Results: Each hybrid configuration had a greater DQE than its direct AMFPI layer alone. The DQE improvement was largest at low spatial frequencies in both front- and back-irradiation (BI) geometries due to increased x-ray quantum efficiency provided by the scintillator. DQE improvements persisted at higher frequencies in BI geometry due to preferential x-ray absorption in a-Se. Matching the x-ray-to-charge conversion gains of a hybrid AMFPI's direct and indirect detection layers affects its Swank factor and, thus, DQE(0). X-ray cross talk has a negligible impact on the DQE ( f ) of hybrid AMFPIs with sufficiently high optical quantum efficiency.
Conclusion: An optimized hybrid AMFPI can achieve greater DQE performance than current direct or indirect AMFPIs.
© 2020 Society of Photo-Optical Instrumentation Engineers (SPIE).

Entities:  

Keywords:  active matrix flat-panel imager; amorphous selenium; detective quantum efficiency; digital radiography; flat-panel detector; scintillator

Year:  2020        PMID: 32411813      PMCID: PMC7215239          DOI: 10.1117/1.JMI.7.3.033501

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  22 in total

1.  Monte Carlo simulations of the imaging performance of metal plate/phosphor screens used in radiotherapy.

Authors:  C Kausch; B Schreiber; F Kreuder; R Schmidt; O Dössel
Journal:  Med Phys       Date:  1999-10       Impact factor: 4.071

Review 2.  Inorganic scintillators in medical imaging.

Authors:  Carel W E van Eijk
Journal:  Phys Med Biol       Date:  2002-04-21       Impact factor: 3.609

3.  Imaging performance of amorphous selenium based flat-panel detectors for digital mammography: characterization of a small area prototype detector.

Authors:  Wei Zhao; W G Ji; Anne Debrie; J A Rowlands
Journal:  Med Phys       Date:  2003-02       Impact factor: 4.071

Review 4.  Detectors for digital mammography.

Authors:  Martin J Yaffe; James G Mainprize
Journal:  Technol Cancer Res Treat       Date:  2004-08

5.  Modeling granular phosphor screens by Monte Carlo methods.

Authors:  Panagiotis F Liaparinos; Ioannis S Kandarakis; Dionisis A Cavouras; Harry B Delis; George S Panayiotakis
Journal:  Med Phys       Date:  2006-12       Impact factor: 4.071

6.  DQE of wireless digital detectors: comparative performance with differing filtration schemes.

Authors:  Ehsan Samei; Simon Murphy; Olav Christianson
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

7.  A novel EPID design for enhanced contrast and detective quantum efficiency.

Authors:  Joerg Rottmann; Daniel Morf; Rony Fueglistaller; George Zentai; Josh Star-Lack; Ross Berbeco
Journal:  Phys Med Biol       Date:  2016-08-05       Impact factor: 3.609

8.  Rapid Monte Carlo simulation of detector DQE(f).

Authors:  Josh Star-Lack; Mingshan Sun; Andre Meyer; Daniel Morf; Dragos Constantin; Rebecca Fahrig; Eric Abel
Journal:  Med Phys       Date:  2014-03       Impact factor: 4.071

9.  Detection of X-ray photons by solution-processed organic-inorganic perovskites.

Authors:  Sergii Yakunin; Mykhailo Sytnyk; Dominik Kriegner; Shreetu Shrestha; Moses Richter; Gebhard J Matt; Hamed Azimi; Christoph J Brabec; Julian Stangl; Maksym V Kovalenko; Wolfgang Heiss
Journal:  Nat Photonics       Date:  2015-05-25       Impact factor: 38.771

10.  Characterization of polycrystalline lead oxide for application in direct conversion X-ray detectors.

Authors:  O Semeniuk; O Grynko; G Decrescenzo; G Juska; K Wang; A Reznik
Journal:  Sci Rep       Date:  2017-08-17       Impact factor: 4.379

View more