Literature DB >> 20125622

Calculation of modulation transfer functions of x-ray fluorescent screens.

R K Swank.   

Abstract

Formulas have been derived for calculating the modulation transfer function of x-ray intensifying screens. Emphasis has been placed on simplified models where results can be obtained in closed form and a physical understanding more easily realized. For selected cases, the MTF's of transparent screens are calculated by direct integration. The MTF's of diffusing screens are determined from suitable approximate solutions of the Boltzmann equation. The intermediate case and the transition from scattering to nonscattering are discussed. As a byproduct, formulas for light output and signal-to-noise ratio are obtained.

Entities:  

Year:  1973        PMID: 20125622     DOI: 10.1364/AO.12.001865

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  8 in total

1.  Image quality degradation by light scattering in display devices.

Authors:  M J Flynn; A Badano
Journal:  J Digit Imaging       Date:  1999-05       Impact factor: 4.056

2.  Integrated model for estimating phosphor signal and noise transfer characteristics on medical images: application to CdPO3Cl:Mn phosphor screens.

Authors:  D Cavouras; I Kandarakis; G S Panayiotakis; C D Nomicos
Journal:  Med Biol Eng Comput       Date:  2002-05       Impact factor: 2.602

3.  A comparative analysis of OTF, NPS, and DQE in energy integrating and photon counting digital x-ray detectors.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2010-12       Impact factor: 4.071

4.  Back-irradiated and dual-screen sandwich detector configurations for radiography.

Authors:  Anthony R Lubinsky; Adrian Howansky; Hao Zheng; Wei Zhao
Journal:  J Med Imaging (Bellingham)       Date:  2019-07-09

5.  An apparatus and method for directly measuring the depth-dependent gain and spatial resolution of turbid scintillators.

Authors:  Adrian Howansky; A R Lubinsky; Katsuhiko Suzuki; S Ghose; Wei Zhao
Journal:  Med Phys       Date:  2018-10-01       Impact factor: 4.071

6.  Optimization of phosphor-based detector design for oblique x-ray incidence in digital breast tomosynthesis.

Authors:  Raymond J Acciavatti; Andrew D A Maidment
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

7.  Medipix-based Spectral Micro-CT.

Authors:  Hengyong Yu; Qiong Xu; Peng He; James Bennett; Raja Amir; Bruce Dobbs; Xuanqin Mou; Biao Wei; Anthony Butler; Phillip Butler; Ge Wang
Journal:  CT Li Lun Yu Ying Yong Yan Jiu       Date:  2012-12

8.  Modelling the transport of optical photons in scintillation detectors for diagnostic and radiotherapy imaging.

Authors:  Emilie Roncali; Mohammad Amin Mosleh-Shirazi; Aldo Badano
Journal:  Phys Med Biol       Date:  2017-10-04       Impact factor: 3.609

  8 in total