Difference in the artefacts production and the performance of the metal artefact reduction (MAR) tool between the buccal and lingual cortical plates adjacent to zirconium dental implant.

Eduarda Helena Leandro Nascimento1, Rocharles Cavalcante Fontenele1, Gustavo Machado Santaella1, Deborah Queiroz Freitas1.   

Abstract

OBJECTIVES: To quantify the artefacts production and the performance of the metal artefact reduction (MAR) tool, enabled before or after the acquisition, in cortical plates (buccal and lingual) and other regions adjacent to zirconium implants.
METHODS: Cone beam CT scans were acquired using the OP300 Maxio unit before (control group) and after (implant group) the insertion of a zirconium implant into the posterior region of a dry mandible. Three conditions of MAR tool were tested: "without MAR", with "MAR activated after acquisition", and with "MAR activated before acquisition". The standard deviation (SD), contrast-to-noise ratio (CNR) and voxel values were calculated in the buccal and lingual cortical plates, medullary bone and water region, close to the implant. The structural bone analysis was performed in the medullary bone close to the implant.
RESULTS: Overall, in control and implant groups, the lingual cortical had higher SD, lower CNR and lower voxel values than the buccal cortical, regardless of the MAR condition (p < 0.05). Implant caused higher SD values and lower voxel values in adjacent regions "without MAR" (p < 0.05). MAR activation decreased SD and changed voxel values when the implant was present, regardless of MAR activation mode (p < 0.05). The activation of MAR increased the trabecular thickness values for the implant group (p < 0.05).
CONCLUSION: The expression of artefacts adjacent to zirconium implants is greater in the lingual than in the buccal cortical. The greater the expression of artefacts in this region, the greater the effectiveness of the MAR tool in homogenizing the grey values, regardless of the time of its activation.

Entities:  

Keywords:  artefacts; cone beam CT; dental implant; zirconium

Mesh:

Substances:

Year:  2019        PMID: 31276425      PMCID: PMC6951099          DOI: 10.1259/dmfr.20190058

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  27 in total

1.  Quantification of metal artifacts on cone beam computed tomography images.

Authors:  Ruben Pauwels; Harry Stamatakis; Hilde Bosmans; Ria Bogaerts; Reinhilde Jacobs; Keith Horner; Kostas Tsiklakis
Journal:  Clin Oral Implants Res       Date:  2011-12-15       Impact factor: 5.977

2.  Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography.

Authors:  Touraj Razavi; Richard M Palmer; Jonathan Davies; Ron Wilson; Paul J Palmer
Journal:  Clin Oral Implants Res       Date:  2010-07       Impact factor: 5.977

3.  Assessment of buccal marginal alveolar peri-implant and periodontal defects using a cone beam CT system with and without the application of metal artefact reduction mode.

Authors:  K Kamburoglu; E Kolsuz; S Murat; H Eren; S Yüksel; C S Paksoy
Journal:  Dentomaxillofac Radiol       Date:  2013       Impact factor: 2.419

Review 4.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

5.  Influence of acquisition parameters on the magnitude of cone beam computed tomography artifacts.

Authors:  Deborah Queiroz Freitas; Rocharles Cavalcante Fontenele; Eduarda Helena Leandro Nascimento; Taruska Ventorini Vasconcelos; Marcel Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2018-06-27       Impact factor: 2.419

6.  Performance of an artefact reduction algorithm in the diagnosis of in vitro vertical root fracture in four different root filling conditions on CBCT images.

Authors:  G L de Rezende Barbosa; S L Sousa Melo; P N B Alencar; M C C Nascimento; S M Almeida
Journal:  Int Endod J       Date:  2015-06-26       Impact factor: 5.264

7.  Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences.

Authors:  Sergio Lins de-Azevedo-Vaz; Priscila Dias Peyneau; Laura Ricardina Ramirez-Sotelo; Karla de Faria Vasconcelos; Paulo Sérgio Flores Campos; Francisco Haiter-Neto
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol       Date:  2016-01-28

8.  In vitro assessment of artifacts induced by titanium, titanium-zirconium and zirconium dioxide implants in cone-beam computed tomography.

Authors:  Manuel Sancho-Puchades; Christoph H F Hämmerle; Goran I Benic
Journal:  Clin Oral Implants Res       Date:  2014-07-08       Impact factor: 5.977

9.  Magnitude of cone beam CT image artifacts related to zirconium and titanium implants: impact on image quality.

Authors:  Rocharles C Fontenele; Eduarda Hl Nascimento; Taruska V Vasconcelos; Marcel Noujeim; Deborah Q Freitas
Journal:  Dentomaxillofac Radiol       Date:  2018-05-10       Impact factor: 2.419

10.  Artifacts in CT: recognition and avoidance.

Authors:  Julia F Barrett; Nicholas Keat
Journal:  Radiographics       Date:  2004 Nov-Dec       Impact factor: 5.333

View more
  6 in total

1.  Do the number of basis images and metal artifact reduction affect the production of artifacts near and far from zirconium dental implants in CBCT?

Authors:  Eduarda Helena Leandro Nascimento; Hugo Gaêta-Araujo; Rocharles Cavalcante Fontenele; Nicolly Oliveira-Santos; Christiano Oliveira-Santos; Deborah Queiroz Freitas
Journal:  Clin Oral Investig       Date:  2021-02-24       Impact factor: 3.573

Review 2.  The Impact of Cone-Beam Computed Tomography Exposure Parameters on Peri-Implant Artifacts: A Literature Review.

Authors:  Paweł Sawicki; Paweł J Zawadzki; Piotr Regulski
Journal:  Cureus       Date:  2022-03-10

3.  Comparison of the amount of artifacts induced by zirconium and titanium implants in cone-beam computed tomography images.

Authors:  Abbas Shokri; Fariborz Vafaee; Leila Haghighat; Shiva Shahabi; Maryam Farhadian; Mohammad Reza Jamalpour
Journal:  BMC Med Imaging       Date:  2022-09-03       Impact factor: 2.795

4.  Influence of kilovoltage-peak and the metal artifact reduction tool in cone-beam computed tomography on the detection of bone defects around titanium-zirconia and zirconia implants.

Authors:  Rocharles Cavalcante Fontenele; Eduarda Helena Leandro Nascimento; Ana Catarina Imbelloni-Vasconcelos; Luciano Augusto Cano Martins; Andrea Dos Anjos Pontual; Flávia Maria Moraes Ramos-Perez; Deborah Queiroz Freitas
Journal:  Imaging Sci Dent       Date:  2022-07-05

5.  Does the metal artifact reduction algorithm activation mode influence the magnitude of artifacts in CBCT images?

Authors:  Rocharles C Fontenele; Eduarda H L Nascimento; Gustavo M Santaella; Deborah Q Freitas
Journal:  Imaging Sci Dent       Date:  2020-03-17

6.  Magnitude of beam-hardening artifacts produced by gutta-percha and metal posts on cone-beam computed tomography with varying tube current.

Authors:  Hugo Gaêta-Araujo; Eduarda Helena Leandro Nascimento; Rocharles Cavalcante Fontenele; Arthur Xavier Maseti Mancini; Deborah Queiroz Freitas; Christiano Oliveira-Santos
Journal:  Imaging Sci Dent       Date:  2020-03-17
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.